Scope

GB/T 39527-2020 is the English-translated version of 实体面材产品中钙、铝、硅元素含量的测定 化学分析法.

GB/T 39527-2020 is the Chinese standard "Determination of calcium, aluminium and silicon in the solid surface materials—Method of chemical analysis".

Its scope clause reads: This standard specifies the chemical titration and inductively coupled plasma emission spectrometry to determine the content of calcium, aluminum and silicon in solid surface products: Method principle, reagents and equipment, test methods and requirements, precision and inspection report: This standard applies to the determination of calcium, aluminum and silicon content in solid surface products: Artificial granite and artificial stone quartz can be used as a reference: real See Table 1 for the determination range of each element of decent surface products: Table 1 Elements and measurement range Element name determination range a (mass fraction)/% Calcium (calculated as CaO) 0:51~51:45 Aluminum (as Al2O3) 0:50~48:96 Silicon (as SiO2) 0:53~90:49 a The specified measurement range represents the range studied by the precision test: Exceeding this range may also be applicable, but the laboratory is required to perform the test for the out of range: Line verification:. Its clauses include terms and definitions; principle of the method.

Found what you need?

Document preview — GB/T 39527-2020

National Standard of the People's Republic of China

ICS
91.100.15
Classification
Q 21

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Principle of the method

1 Scope

This standard specifies the chemical titration and inductively coupled plasma emission spectrometry to determine the content of calcium, aluminum and silicon in solid surface products:

Method principle, reagents and equipment, test methods and requirements, precision and inspection report:

This standard applies to the determination of calcium, aluminum and silicon content in solid surface products: Artificial granite and artificial stone quartz can be used as a reference: real

See Table 1 for the determination range of each element of decent surface products:

Table 1 Elements and measurement range

Element name determination range a (mass fraction)/%

Calcium (calculated as CaO) 0:51~51:45

Aluminum (as Al2O3) 0:50~48:96

Silicon (as SiO2) 0:53~90:49 a The specified measurement range represents the range studied by the precision test: Exceeding this range may also be applicable, but the laboratory is required to perform the test for the out of range:

Line verification:

2 Normative references

The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article

Pieces: For undated references, the latest version (including all amendments) applies to this document:

GB/T 6379:1 Measurement methods and accuracy of results (accuracy and precision) Part 1: General principles and definitions

GB/T 6379:2 Accuracy of measurement methods and results (accuracy and precision) Part 2: Determine the repeatability of standard measurement methods

Basic methods of sex and reproducibility

GB/T 6682 Analytical laboratory water specifications and test methods

JC/T 908 Artificial stone

3 Terms and definitions

The terms and definitions defined in JC/T 908 apply to this document:

4 Principle of the method

The sample is melted by sodium hydroxide at high temperature to obtain a clear solution to be tested, using chemical titration or inductively coupled plasma emission spectrometry

Perform qualitative and quantitative testing of calcium, aluminum and silicon in the solution to be tested, and calculate the oxide content:

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 39527-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 39527-2020

$210.00