GB/T 39527-2020Determination of calcium, aluminium and silicon in the solid surface materials—Method of chemical analysis (English PDF)
实体面材产品中钙、铝、硅元素含量的测定 化学分析法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 39527-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 14, 2020
Implementation date
November 1, 2021
Scope
GB/T 39527-2020 is the English-translated version of 实体面材产品中钙、铝、硅元素含量的测定 化学分析法.
GB/T 39527-2020 is the Chinese standard "Determination of calcium, aluminium and silicon in the solid surface materials—Method of chemical analysis".
Its scope clause reads: This standard specifies the chemical titration and inductively coupled plasma emission spectrometry to determine the content of calcium, aluminum and silicon in solid surface products: Method principle, reagents and equipment, test methods and requirements, precision and inspection report: This standard applies to the determination of calcium, aluminum and silicon content in solid surface products: Artificial granite and artificial stone quartz can be used as a reference: real See Table 1 for the determination range of each element of decent surface products: Table 1 Elements and measurement range Element name determination range a (mass fraction)/% Calcium (calculated as CaO) 0:51~51:45 Aluminum (as Al2O3) 0:50~48:96 Silicon (as SiO2) 0:53~90:49 a The specified measurement range represents the range studied by the precision test: Exceeding this range may also be applicable, but the laboratory is required to perform the test for the out of range: Line verification:. Its clauses include terms and definitions; principle of the method.
Found what you need?
Document preview — GB/T 39527-2020
National Standard of the People's Republic of China
- ICS
- 91.100.15
- Classification
- Q 21
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Principle of the method
1 Scope
This standard specifies the chemical titration and inductively coupled plasma emission spectrometry to determine the content of calcium, aluminum and silicon in solid surface products:
Method principle, reagents and equipment, test methods and requirements, precision and inspection report:
This standard applies to the determination of calcium, aluminum and silicon content in solid surface products: Artificial granite and artificial stone quartz can be used as a reference: real
See Table 1 for the determination range of each element of decent surface products:
Table 1 Elements and measurement range
Element name determination range a (mass fraction)/%
Calcium (calculated as CaO) 0:51~51:45
Aluminum (as Al2O3) 0:50~48:96
Silicon (as SiO2) 0:53~90:49 a The specified measurement range represents the range studied by the precision test: Exceeding this range may also be applicable, but the laboratory is required to perform the test for the out of range:
Line verification:
2 Normative references
The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article
Pieces: For undated references, the latest version (including all amendments) applies to this document:
GB/T 6379:1 Measurement methods and accuracy of results (accuracy and precision) Part 1: General principles and definitions
GB/T 6379:2 Accuracy of measurement methods and results (accuracy and precision) Part 2: Determine the repeatability of standard measurement methods
Basic methods of sex and reproducibility
GB/T 6682 Analytical laboratory water specifications and test methods
JC/T 908 Artificial stone
3 Terms and definitions
The terms and definitions defined in JC/T 908 apply to this document:
4 Principle of the method
The sample is melted by sodium hydroxide at high temperature to obtain a clear solution to be tested, using chemical titration or inductively coupled plasma emission spectrometry
Perform qualitative and quantitative testing of calcium, aluminum and silicon in the solution to be tested, and calculate the oxide content:
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 39527-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 39527-2020