Scope

GB/T 39296-2020 is the English-translated version of 循环冷却水处理运行效果评价 监测换热器法.

GB/T 39296-2020 is the Chinese standard "Operation effect evaluation of recirculating cooling water treatment—Method of monitoring heat exchanger".

Its scope clause reads: This standard specifies the materials and equipment, methods, processes, and results calculations used for the evaluation of the operation effect of circulating cooling water treatment by the monitoring heat exchanger method And evaluation report and other technical requirements.

This standard is applicable to the monitoring of corrosion, fouling and biological sludge on the heat exchanger by monitoring the bypass of the circulating cooling water system under normal operating conditions To evaluate the water treatment operation effect of the indirect cooling open circulating cooling water system. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 39296-2020

National Standard of the People's Republic of China

ICS
13.060.25
Classification
G 76

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 Circulating cooling water
  • 3.2 Circulating cooling water system
  • 3.3 Monitoring heat exchanger
  • 3.4 Monitoring test tube
  • 3.5 Pressure drop monitoring tube

1 Scope

This standard specifies the materials and equipment, methods, processes, and results calculations used for the evaluation of the operation effect of circulating cooling water treatment by the monitoring heat exchanger method

And evaluation report and other technical requirements.

This standard is applicable to the monitoring of corrosion, fouling and biological sludge on the heat exchanger by monitoring the bypass of the circulating cooling water system under normal operating conditions

To evaluate the water treatment operation effect of the indirect cooling open circulating cooling water system.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article

Pieces. For undated references, the latest version (including all amendments) applies to this document.

GB/T 10123-2001 Basic terms and definitions for corrosion of metals and alloys

GB/T 18590 Corrosion pitting assessment method of metals and alloys

HG/T 3523 Cooling water chemical treatment standard corrosion test piece technical conditions

3 Terms and definitions

The following terms and definitions defined in GB/T 10123-2001 apply to this document. For ease of use, the following is repeated

Certain terms and definitions in GB/T 10123-2001.

3.1 Circulating cooling water

For the purpose of directly or indirectly cooling petroleum, chemical, steel products or meeting the needs of other industrial production, returning to the cooling building after heat exchange

The temperature of the material is lowered, and the water used is recycled after necessary treatment.

3.2 Circulating cooling water system

A water supply system that uses water as a cooling medium and circulates.

Note. It is composed of heat exchange equipment, cooling equipment, processing facilities, water pumps, pipelines and other related facilities. This standard specifically refers to the intercooled open circulating cooling water system, namely

The circulating cooling water system indirectly transfers heat to the cooled medium and directly contacts the atmosphere to dissipate heat.

3.3 Monitoring heat exchanger

It is a small heat exchanger that simulates the working conditions of the water cooler in the circulating cooling water system and monitors the corrosion and deposition conditions and changing trends of the circulating cooling water system.

3.4 Monitoring test tube

test tube

Standard metal straight pipe placed in the monitoring heat exchanger for monitoring corrosion and deposition.

3.5 Pressure drop monitoring tube

Straight stainless steel pipe installed horizontally by measuring the pressure difference between both ends to monitor the amount of attached biological slime.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 39296-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 39296-2020

$240.00