Valid

GB/T 39173-2020Smart factory—The effectiveness assessment methods of safety monitoring (English PDF)

智能工厂 安全监测有效性评估方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (27 pages)

Need quotation for your management?

Get a formal quotation for GB/T 39173-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 11, 2020

Implementation date

May 1, 2021

Scope

GB/T 39173-2020 is the English-translated version of 智能工厂 安全监测有效性评估方法.

GB/T 39173-2020 is the Chinese standard "Smart factory—The effectiveness assessment methods of safety monitoring".

Its scope clause reads: This standard specifies the general requirements for the effectiveness evaluation method of safety monitoring, flame, combustible gas, toxic gas and ultrasonic detector safety Methods of monitoring effectiveness evaluation.

This standard applies to the safety monitoring of flames, combustible gases, toxic gases and ultrasound in smart factories in the petroleum, petrochemical, and natural gas fields.

Test for effectiveness evaluation. Smart factories in other fields can be implemented by reference. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 39173-2020

National Standard of the People's Republic of China

ICS
25.040.40
Classification
N 10

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Abbreviations
  • 5 General requirements
  • 5.1 Objective
  • 5.2 Stage 3 of carrying out effectiveness evaluation
  • 5.3 Personnel requirements
  • 5.4 Detector evaluation requirements
  • 5.5 Evaluation Technology
  • 5.6 Evaluation Process
  • 5.7 Evaluation tool
  • 5.8 Data collection
  • 5.9 Evaluation Report
  • 6 Evaluation of the effectiveness of flame detector safety monitoring
  • 6.1 Evaluation requirements
  • 6.2 Identification of hazard types
  • 6.3 Defining the fire area
  • 6.4 Definition of coverage target
  • 7 Evaluation of effectiveness of safety monitoring of combustible gas detector
  • 7.1 Evaluation requirements
  • 7.2 Identification of hazard types
  • 7.3 Defining risk areas
  • 7.4 CFD calculation and input
  • 7.5 Definition of coverage target
  • 8 Evaluation of the effectiveness of safety monitoring of toxic gas detectors
  • 8.1 Evaluation requirements
  • 8.2 Identification of hazard types
  • 8.3 Defining risk areas
  • 8.4 CFD calculation and input
  • 8.5 Definition of coverage target
  • 9 Evaluation of the effectiveness of ultrasonic detector safety monitoring
  • 9.1 Purpose
  • 9.2 Identification of hazard types
  • 9.3 Defining risk areas
  • 9.4 Coverage target
  • Appendix A (informative appendix) Detector coverage assessment technology
  • Appendix B (informative appendix) Leakage frequency of typical equipment
  • Appendix C (informative appendix) Three-dimensional digital model
  • Appendix D (informative appendix) CFD calculation process and method
  • Appendix E (informative appendix) Applicable area of smart factory heat detectors
  • Appendix F (informative appendix) Table of fire zone classification for typical hydrocarbon installations
  • Appendix G (Informative Appendix) Definition of Leakage Volume in Scenario Analysis
  • References

1 Scope

This standard specifies the general requirements for the effectiveness evaluation method of safety monitoring, flame, combustible gas, toxic gas and ultrasonic detector safety

Methods of monitoring effectiveness evaluation.

This standard applies to the safety monitoring of flames, combustible gases, toxic gases and ultrasound in smart factories in the petroleum, petrochemical, and natural gas fields.

Test for effectiveness evaluation. Smart factories in other fields can be implemented by reference.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article

Pieces. For undated references, the latest version (including all amendments) applies to this document.

GB 50116-2013 Code for design of automatic fire alarm system

GB/T 50493-2019 Design standard for the detection and alarm of combustible gas and toxic gas in petrochemical industry

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 flammable gas

Combustible gas or combustible vapor formed by vaporization of Class A gas or Class A, B and A combustible liquids.

Note 1.Also known as flammable gas.

Note 2.Rewrite GB/T 50493-2019 and define 2.0.1.

3.2 Toxic gas

In the process of occupational activities, workers contact or breathe toxic gases or vapors that can cause death or permanent health damage through skin contact.

[GB/T 50493-2019, definition 2.0.2]

3.3 Release source

The location or location that can release and form an explosive gas environment or a toxic gas environment.

[GB/T 50493-2019, definition 2.0.3]

3.4 detector

Electronic equipment that converts the concentration of combustible gas, toxic gas or oxygen into electrical signals.

Note 1.Also known as detector.

Note 2.Rewrite GB/T 50493-2019 and define 2.0.4.

3.5 Safety monitoring

It is used in the monitoring and detection of flame, combustible gas and toxic gas in smart factory.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 27 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 39173-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
27 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 39173-2020

$480.00