GB/T 39109-2020Textiles - Determination of benzophenone ultraviolet absorbents (English PDF)
纺织品 二苯甲酮类紫外线吸收剂的测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 39109-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 21, 2020
Implementation date
May 1, 2021
Scope
GB/T 39109-2020 is the English-translated version of 纺织品 二苯甲酮类紫外线吸收剂的测定.
GB/T 39109-2020 is the Chinese standard "Textiles - Determination of benzophenone ultraviolet absorbents". Its scope clause reads: This Standard specifies a method for the determination of 11 kinds of benzophenone ultraviolet absorbents in textile products through high-performance liquid chromatograph - diode array detector (HPLC-DAD).
This Standard is applicable to the determination of benzophenone ultraviolet absorbents in various types of textile products. Its clauses include principle; reagents; equipment and instruments; analytical procedures; result calculation and expression; lower limit of determination and precision.
Found what you need?
Document preview — GB/T 39109-2020
National Standard of the People's Republic of China
- ICS
- 59.080.01
- Classification
- W 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Principle4
- 4 Reagents4
- 5 Equipment and Instruments5
- 6 Analytical Procedures5
- 7 Result Calculation and Expression8
- 8 Lower Limit of Determination and Precision8
- 9 Test Report9
- Ultraviolet Absorbents10
- Absorbents16
1 Scope
This Standard specifies a method for the determination of 11 kinds of benzophenone ultraviolet absorbents in textile products through high-performance liquid chromatograph - diode array detector (HPLC-DAD).
This Standard is applicable to the determination of benzophenone ultraviolet absorbents in various types of textile products.
2 Normative References
The following documents are indispensable to the application of this document. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document.
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods
3 Principle
Use methanol to ultrasonically extract the sample; use a filter membrane to filter and purify it. Then, use high-performance liquid chromatograph - diode array detector (HPLC-DAD) for determination and confirmation. Adopt the external standard method for quantification.
4 Reagents
4.1
Unless it is otherwise specified, all used reagents are analytically pure; water is
Grade-1 water specified in GB/T 6682.
4.2 Methanol
chromatographically pure.
4.3 Isopropanol
chromatographically pure.
4.4 Formic acid
chromatographically pure.
4.5 Formic acid solution
1 mL/L. Measure-take 1 mL of formic acid (4.4); use water to dissolve it and reach a constant volume of 1,000 mL, then, shake it well.
4.6
Methanol-isopropanol solution containing 1 mL/L formic acid (70 + 30): measure- take 699 mL of methanol (4.2), 300 mL of isopropanol (4.3) and 1 mL of methanol (4.4);
mix it up and shake it well.
4.7 Benzophenone ultraviolet absorbent standard substance (purity >= 98%): see
Appendix A.
4.8
Benzophenone ultraviolet absorbent standard stock solution (1,000 mg/L):
accurately weigh-take the standard substance specified in 4.7, accurate to 0.1 mg; use methanol (4.2) to dissolve the benzophenone ultraviolet absorbent standard substance and reach a constant volume; prepare it into a single-component stock solution with a concentration of 1,000 mg/L.
NOTE: the standard stock solution shall be stored in the dark at 0 °C ~ 4 °C; the validity period should be 3 months.
4.9 Benzophenone ultraviolet absorbent standard working solution
respectively transfer-take an appropriate volume of the standard stock solution (4.8); use methanol (4.2) to dilute it; prepare into standard working solution with different concentrations:
0.0 mg/L, 0.5 mg/L, 1 mg/L, 2 mg/L, 5 mg/L, 10 mg/L and 20 mg/L.
NOTE: the standard working solution shall be stored in the dark at 0 °C ~ 4 °C; the validity period should be 1 month.
5 Equipment and Instruments
5.1 Extractor
with a sealing plug; about 60 mL; made of hard glass in a tubular form.
5.2 Ultrasonic generator
with a working frequency of 40 kHz.
5.3 Organic phase filter membrane
with a pore size of 0.45 µm.
5.4 Analytical balance
the division value is respectively 0.1 mg and 0.01 g.
5.5 High-performance liquid chromatograph
equipped with a diode array detector.
6 Analytical Procedures
6.1 Sample Preparation and Extraction
7 Result Calculation and Expression
The determination result of this Method shall be respectively expressed in the detection results of the benzophenone ultraviolet absorbents, and be calculated in accordance with Formula (1):
Where,
Xi ---the content of the benzophenone ultraviolet absorbent i extracted from the sample, expressed in (mg/kg);
Ai ---the peak area (or peak height) of the benzophenone ultraviolet absorbent i in the test solution;
Ais ---the peak area (or peak height) of the benzophenone ultraviolet absorbent i in the standard working solution;
ci ---the mass concentration of the benzophenone ultraviolet absorbent i in the standard working solution, expressed in (mg/L);
c0---the mass concentration of the benzophenone ultraviolet absorbent i in the blank test, expressed in (mg/L);
F---dilution factor;
V---the final volume of the test solution, expressed in (mL);
m---the mass of the sample, expressed in (g).
The test result shall be respectively expressed in the detection results of the various benzophenone ultraviolet absorbents. The calculation result shall be retained to integers.
8 Lower Limit of Determination and Precision
8.1 Lower Limit of Determination
The lower limit of determination of this Method is 10 mg/kg.
8.2 Precision
The relative standard deviation of two test results obtained through mutually independent tests conducted in the same laboratory, and by the same operator using the same equipment and the same test method on the same object in a short period […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 39109-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 39109-2020