Valid

GB/T 38924.7-2020Environmental test methods for civil small and light unmanned aircraft system - Part 7: Humidity test (English PDF)

民用轻小型无人机系统环境试验方法 第7部分:湿热试验

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 38924.7-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 21, 2020

Implementation date

February 1, 2021

Scope

GB/T 38924.7-2020 is the English-translated version of 民用轻小型无人机系统环境试验方法 第7部分:湿热试验.

GB/T 38924.7-2020 is the Chinese standard "Environmental test methods for civil small and light unmanned aircraft system - Part 7: Humidity test".

Its scope clause reads: This part of GB/T 38924 specifies the civil light and small unmanned aerial vehicle (take-off weight 0.25kg~150kg) system (including aircraft and Ground station) damp heat test test conditions, test equipment and instruments, test process, test interruption and recovery, test result evaluation and test report Report etc. This part is applicable to civilian light and small drones that will experience hot and humid environments during use (take-off weight is 0.25kg~150kg) System (including aircraft and ground station) to determine the ability of civilian light and small UAV systems to withstand natural or induced humid atmospheres. Its clauses include test conditions.

Found what you need?

Document preview — GB/T 38924.7-2020

National Standard of the People's Republic of China

ICS
49.020
Classification
V 35

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope1
  • 2 Normative references1
  • 3 Test conditions1
  • 3.1 Device under test1
  • 3.2 Test conditions and tolerances1
  • 4 Test equipment and instruments2
  • 5 Test process2
  • 5.1 Test preparation2
  • 5.2 Pretreatment2
  • 5.3 Inspection before test2
  • 5.4 Test Step3
  • 5.5 Inspection after the test3
  • 6 Test interruption and resumption3
  • 6.1 Under-test interruption3
  • 6.2 Over-test interruption3
  • 7 Evaluation of test results3
  • 8 Test report3

1 Scope

This part of GB/T 38924 specifies the civil light and small unmanned aerial vehicle (take-off weight 0.25kg~150kg) system (including aircraft and

Ground station) damp heat test test conditions, test equipment and instruments, test process, test interruption and recovery, test result evaluation and test report

Report etc.

This part is applicable to civilian light and small drones that will experience hot and humid environments during use (take-off weight is 0.25kg~150kg)

System (including aircraft and ground station) to determine the ability of civilian light and small UAV systems to withstand natural or induced humid atmospheres.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article

Pieces. For undated references, the latest version (including all amendments) applies to this document.

GB/T 38924.1-2020 Environmental test method for civil light and small unmanned aerial vehicle systems Part 1.General

3 Test conditions

3.1 Device under test

The equipment under test shall meet the following requirements.

a) The technical status of the tested equipment should be consistent with the content of the submitted product information;

b) The number of tested equipment should meet the test requirements, and at least one set of tested equipment is required;

c) The tested equipment should have quality inspection certificates such as enterprise qualification certificates.

3.2 Test conditions and tolerances

For the damp and heat test conditions and tolerances of civil light and small UAV systems, see Table 1.

Table 1 Test conditions and tolerances

Serial number test phase temperature

Temperature tolerance

Relative humidity

Relative humidity tolerance time

Test period a

1 Heating stage 30->high temperature b ±2 >=85-2±0.25

2 High temperature temperature in high temperature and high humidity phase ±2 95 ±4 >=6

3 High temperature temperature in the cooling stage->30 ±2 >=85-16±0.25

24h is 1 cycle a The number of test cycles can be selected from 1, 2, 4, 6, 8, and 10.

b The high temperature temperature can be selected from 40°C, 45°C, 50°C, 55°C, 60°C, 65°C, but it cannot exceed the high temperature exposure limit of the equipment under test.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 38924.7-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 38924.7-2020

$90.00