GB/T 38912-2020Test method for closed-end burst of zirconium tubes at room temperature (English PDF)
锆管室温闭端爆破试验方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 38912-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
June 2, 2020
Implementation date
May 1, 2021
Scope
GB/T 38912-2020 is the English-translated version of 锆管室温闭端爆破试验方法.
GB/T 38912-2020 is the Chinese standard "Test method for closed-end burst of zirconium tubes at room temperature".
Its scope clause reads: This Standard specifies the test method for closed-end internal pressure burst of zirconium tubes at room temperature of 10 °C ~ 35 °C. This Standard applies to the closed-end internal pressure burst test of zirconium tubes at room temperature of 10 °C ~ 35 °C, and is used for the determination of bursting strength and percent total circumferential elongation at the crevasse of zirconium tubes at room temperature.
Its clauses include terms and definitions; principle; instruments and apparatuses; sample; test procedure; test report. It was issued by the State Administration for Market Regulation on JUNE 02, 2020 and took effect on APRIL 01, 2021.
Found what you need?
Document preview — GB/T 38912-2020
National Standard of the People's Republic of China
- ICS
- 77.040.10
- Classification
- H 22
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions4
- 4 Principle5
- 5 Instruments and apparatuses5
- 6 Sample6
- 7 Test procedure7
- 8 Test report9
1 Scope
This Standard specifies the test method for closed-end internal pressure burst of zirconium tubes at room temperature of 10 °C ~ 35 °C.
This Standard applies to the closed-end internal pressure burst test of zirconium tubes at room temperature of 10 °C ~ 35 °C, and is used for the determination of bursting strength and percent total circumferential elongation at the crevasse of zirconium tubes at room temperature.
2 Normative references
The following documents are indispensable for the application of this document.
For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 8170, Rules of rounding off for numerical values & expression and judgment of limiting values
3 Terms and definitions
The following terms and definitions are applicable to this document.
3.1 Maximum fluid pressure
The maximum pressure value of the fluid acting on the end of the sample, during the entire loading process of the test.
3.2 Bursting strength
The maximum stress value that is measured when the sample suddenly bursts, when the tube sample is subject to a burst test and a pressure is continuously applied through a liquid or other medium.
5 Instruments and apparatuses
5.2.3 The pumping system shall be rigid, and its energy storage shall be as low as possible according to the actual situation. There shall be no pressure fluctuations in each stroke of the pump.
5.3 Valve
The various valves in the testing machine shall have the functions of controlling and adjusting the pressure, and shall be able to ensure the safety of the test.
5.4 Pressure transmitter
5.4.1 The pressure transmitter shall have sufficient capacity to monitor the pressure of the system, and to ensure that the test software records the maximum fluid pressure reached during the test.
5.4.2 The measurement accuracy of the pressure transmitter shall be level-0.5 or better; the verification period shall not exceed 12 months.
5.4.3 The data collection location of the pressure transmitter shall be as close as possible to the sample.
5.5 Dimension measuring tools
5.5.1 Use an outside micrometer or other measuring tools of equivalent accuracy for the outer diameter measurement; the accuracy of the measuring tool shall not be less than 0.005 mm.
5.5.2 Use a micrometer for measuring pipe wall thicknesses or other measuring tools of equivalent accuracy for the wall thickness measurement; the accuracy of the measuring tool shall not be less than 0.005 mm.
5.5.3 Use a vernier caliper or other measuring tools of equivalent accuracy to measure the circumference after breaking; the accuracy of the measuring tool shall not be less than 0.05 mm.
6 Sample
6.1 General requirements
6.1.1 The sample cutting location and quantity shall be implemented in accordance with the relevant product technical requirements. The cut can be chamfered and deburred, but there shall be no deformation.
6.1.2 The sample cutting length shall be able to ensure that the unsupported length is not less than 10 times the nominal outer diameter of the sample. […]
6.2 Sample preparation
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 38912-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 8170-1987 — Rules for rounding off of numerical values
GB/T 8170-2008 — Rules of rounding off for numerical values & expression and judgement of limiting values
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 38912-2020