GB/T 38658-2020Guidance for the extension of validity of type tests of AC metal enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV (English PDF)
Also coversGBT38658-2020
Open the GB/T 38658-2020 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
March 31, 2020
Implementation date
October 1, 2020
Scope
GB/T 38658-2020 (Guidance for the extension of validity of type tests of AC metal enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV) is available as an English-translated PDF.
GB/T 38658-2020 — This standard specifies the application and extension of the effectiveness of the type test of 3.6kV ~ 40.5kV AC metal-enclosed switchgear and control equipment Criteria and general methods for extending the validity of type tests. This standard applies to AC metal-enclosed switchgear and rated voltage 3.6kV ~ 40.5kV as specified in GB/T 3906-2020 and Control devices, and other devices in the same enclosure that may affect each other. This standard applies to extending the validity of type tests performed on a sample with a set of determined ratings to the same family Other complete switchgears with different ratings or different component arrangements. Note. In order to carry out consistent conformity assessment and realize the optimization of type tests, this standard supports the composition of functional units of switchgear and control equipment of the same family Selection of typical samples. This standard combines mature technical and physical principles, manufacturer and user experience and calculation to establish a type test Extended guidelines for effectiveness to cover multiple designs and ratings.
Document preview — GB/T 38658-2020
National Standard of the People's Republic of China
- ICS
- 29.120.40
- Classification
- K 43
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 441 1984/AMD1..2000;
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the redrafting method to modify and adopt IEC /T R62271-307..2015 "High Voltage Switchgear and Control Equipment Part 307
Points. Type test of AC metal enclosed and solid insulated enclosed switchgear and control equipment with rated voltage above 1kV and 52kV
"Extended Validity Guidelines."
Compared with IEC /T R62271-307..2015, this standard has structural adjustments. Change 1.1 of IEC /T R62271-307..2015
For "1 Scope", 1.2 was changed to "2 Normative Reference Documents", so that the subsequent article number was postponed.
The technical differences between this standard and IEC /T R62271-307..2015 and the reasons are as follows.
--- With regard to normative quotation documents, this standard has been adjusted with technical differences to suit China's technical conditions and adjustments
The situation is reflected in Chapter 2 "Regulatory Reference Documents", with specific adjustments as follows.
* Replace IEC 60050-441. 1984 and IEC 60050- with GB/T 2900.20-2016 which adopts international standards
441 1984/AMD1..2000;
* Replaced IEC 62271-200..2011 with GB/T 3906-2020, which was modified to adopt international standards;
* Replaced IEC 62271-1..2007 and IEC 62271-1 with GB/T 11022-2011 which adopts international standards.
2007/AMD1..2011;
* Deleted IEC 62271-201..2014.
--- Deleted the solid insulated enclosed switchgear and control equipment that do not exist in China in Chapter 5 of IEC /T R62271-307..2015
Related extensions.
--- Deleted the extension criterion for the cross-sectional area of conductors in Article 5 of Table 7 of IEC /T R62271-307..2015.
This standard has made the following editorial changes.
--- To be consistent with China's technical standard system, the standard name was changed to "3.6kV ~ 40.5kV AC metal-enclosed switchgear and control
"Guidelines for the Validation of Type Testing of Manufacturing Equipment";
--- Adjust references.
This standard was proposed by the China Electrical Equipment Industry Association.
This standard is under the jurisdiction of the National High Voltage Switchgear Standardization Technical Committee (SAC/TC65).
This standard was drafted by. Xi'an High Voltage Apparatus Research Institute Co., Ltd., China Electric Power Research Institute Co., Ltd., Shanghai Pinggaotian
Ling Switch Co., Ltd., ABB (China) Co., Ltd., Cooper (Ningbo) Electric Co., Ltd., Shanghai Electric Transmission and Distribution Test Center Co., Ltd.
Division, Schneider Electric (Xiamen) Switchgear Co., Ltd., Schneider Electric (China) Co., Ltd., Chuankai Electric Co., Ltd., Guangdong Power Grid have
Co., Ltd. Electric Power Research Institute, Liaoning High Voltage Electrical Product Quality Inspection Co., Ltd., Jiangsu Huaguan Electric Group Co., Ltd., China
China Southern Power Grid Co., Ltd. EHV Transmission Company Maintenance Test Center, Guangdong Zhengchao Electric Co., Ltd., State Grid Anhui Electric Power Company
Electric Power Research Institute, State Grid Shaanxi Electric Power Research Institute, Hangzhou Electric Power Equipment Manufacturing Co., Ltd. Lin'an Hengxin Complete Electric System
Manufacturing companies, Pinggao Group Co., Ltd., Qingdao Terad Electric Co., Ltd., Risheng Group Co., Ltd., Shandong Taikai
Co., Ltd., Shandong Taikai Vacuum Switch Co., Ltd., Eaton Power Equipment Co., Ltd., Eaton Electric Co., Ltd., Henan High Voltage Electric Appliance Research
Office Co., Ltd., Huayi Electric Co., Ltd., Jiangsu Rugao High Voltage Electric Co., Ltd., Beijing Beikai Electric Co., Ltd., Beijing
Shuangjie Electric Co., Ltd., Ningbo Tianlun Electric Co., Ltd., Shanghai Anyiji Enterprise Development Co., Ltd., Shanghai Siemens Switch Co., Ltd.
Company, Shaanxi Zhengtai Intelligent Electric Co., Ltd., Shenzhen Guanghui Electric Industrial Co., Ltd., Shenzhen Jinbolian Electric Power Technology Co., Ltd., 4
Chuan Electric Group Co., Ltd., Tianshui Great Wall Switch Factory Co., Ltd., Xiamen Hengyuan New Power Equipment Co., Ltd., Xi'an Jiaotong University,
Xi'an Xidian Electric Research Institute Co., Ltd., Xidian Baoji Electric Co., Ltd., Siemens Medium Voltage Switching Technology (Wuxi) Co., Ltd., He
Nanhua Shenglongyuan Electric Co., Ltd., Zhejiang Switch Factory Co., Ltd., Zhejiang Kaihua Qiyi Electric Equipment Co., Ltd., Guangdong Jinhuilong
Switchgear Co., Ltd., Yunnan Power Grid Co., Ltd. Electric Power Research Institute.
1 Scope
This standard specifies the application and extension of the effectiveness of the type test of 3.6kV ~ 40.5kV AC metal-enclosed switchgear and control equipment
Criteria and general methods for extending the validity of type tests.
This standard applies to AC metal-enclosed switchgear and rated voltage 3.6kV ~ 40.5kV as specified in GB/T 3906-2020 and
Control devices, and other devices in the same enclosure that may affect each other.
This standard applies to extending the validity of type tests performed on a sample with a set of determined ratings to the same family
Other complete switchgears with different ratings or different component arrangements.
Note. In order to carry out consistent conformity assessment and realize the optimization of type tests, this standard supports the composition of functional units of switchgear and control equipment of the same family
Selection of typical samples. This standard combines mature technical and physical principles, manufacturer and user experience and calculation to establish a type test
Extended guidelines for effectiveness to cover multiple designs and ratings.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this article
Pieces. For the cited documents without date, the latest version (including all amendments) applies to this document.
GB/T 2900.20-2016 Electrical engineering terminology high-voltage switchgear and control equipment (IEC 60050-441. 1984, MOD)
GB/T 3906-2020 3.6kV ~ 40.5kV AC metal-enclosed switchgear and control equipment (IEC 62271-200..2011,
MOD)
GB/T 11022-2011 Common technical requirements for high-voltage switchgear and control equipment standards (IEC 62271-1..2007, MOD)
3 Terms and definitions
The terms and definitions defined in GB/T 2900.20-2016, GB/T 3906-2020 and GB/T 11022-2011 and the following apply
In this document. For ease of use, the following repeatedly lists some terms and GB/T 2900.20-2016 and GB/T 3906-2020
definition.
3.101
Switchgear and controlgear
The combination of switchgear and its related control, measurement, protection and regulation equipment, as well as the electrical connection between these devices and equipment
The general term for the assembly of connectors, accessories, shells and supports.
[GB/T 2900.20-2016, definition 3.1]
3.102
Assembly (of switchgear and controlgear)
A combination of switchgear and/or control equipment and all internal electrical and mechanical connections.
Note 1. The final assembly consists of one or more functional units.
Note 2. Rewrite GB/T 2900.20-2016, definition 4.1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 3906-2020Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV
- GB/T 11022-2011Common specifications for high-voltage alternating-current switchgear and controlgear standards
GB/T 2900.20-2016 · IEC 60050 · IEC 62271
How to Buy GB/T 38658-2020
- 1Add to cart. Click the "Buy GB/T 38658-2020" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 3906-2020 — Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV
GB/T 46830.2-2026 — Plastics - Liquid crystal polymer (LCP) moulding and extrusion materials - Part 2: Preparation of test specimens and determination of properties
GB/T 28593-2026 — Sand and dust weather warning levels
Secure payment via Stripe
Payments accepted
GB/T 38658-2020
$480.00