GB/T 38281.1-2019 (Indicator light units for household and similar fixed-electrical installations -- Part 1: General requirements) is available as an English-translated PDF.

GB/T 38281.1-2019 — This part of GB/T 38281 specifies the structure, electrical performance, and mechanical characteristics of indicator lamps for household and similar fixed electrical installations. Mechanical performance and other technical requirements. This section applies to a stand-alone indicator device intended to provide a visible signal. The device is designed for indoor or outdoor use in homes. Use and similar fixed electrical devices, only for alternating current, rated voltage does not exceed 440V, rated power does not exceed 10W. Note 1. The indicator devices within the scope of this section are not used as light sources for lighting [see GB 7000]. This section also applies to installation boxes with indicator units, except for concealed installation boxes with concealed indicator units [according to GB/T 17466]. This section does not apply to indicators installed on products that meet their own standards, they are to be tested as part of the product. The indicator device conforming to this section is suitable for use in an ambient temperature that normally does not exceed 35 ° C and occasionally reaches 40 ° C. Special structures may be required in places with special conditions, such as ships, vehicles, and dangerous places where explosions may occur. Note 2. LEDs and lights are not considered as indicator devices, only as components.

Document preview — GB/T 38281.1-2019

National Standard of the People's Republic of China

ICS
29.120.99
Classification
K 65

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 terms and definitions

Foreword

GB/T 38281 `` Indicator devices for household and similar fixed electrical installations '' is divided into the following sections.

--- Part 1. General requirements;

--- Part 2. Special requirements.

This part is the first part of GB/T 38281.

This section is drafted in accordance with the rules given in GB/T 1.1-2009.

This section uses the redrafting method to modify the use of IEC 62094-1..2002

Part 1. General requirements.

Compared with IEC 62094-1..2002, this part has structural changes.

* Added the title "Accessible parts" in 10.2, the suspension section at 10.2 was changed to 10.2.1, the original 10.2.1 was changed to 10.2.2, and the original 10.2.2

Changed to 10.2.3;

* 13.3 Added the first-level heading "Fixing requirements for covers, covers, and starting elements to ensure protection against electric shock." The 13.3 suspension section was changed to

13.3.1, former 13.3.1 changed to 13.3.2, former 13.3.2 changed to 13.3.3, former 13.3.3 changed to 13.3.4;

* The suspension section at 14.2 was changed to 14.2.1, the title "Overview" was added, the original 14.2.1 was changed to 14.2.2, and the suspension section in the clause was changed

For 14.2.2.1, add the title "General requirements". The original 14.2.1.1 is changed to 14.2.2.2, the original 14.2.1.2 is changed to 14.2.2.3, the original

14.2.2 changed to 14.2.3;

* The suspension section in Chapter 15 was changed to 15.1, the original 15.1 was changed to 15.2, and the original 15.2 was changed to 15.3;

* The suspension section in Chapter 17 was changed to 17.1, and the title "Overview" was added; the original 17.1 was changed to 17.2, and the title "Impact Test" was added.

17.2 was changed to 17.3, and the title "cylinder test" was added, the original 17.3 was changed to 17.4, and the title was "threaded gland", the original

17.4 was changed to 17.5, and the title "Indicator device with connecting line" was added. The original 17.5 was changed to 17.6, and the title was added.

"Removability or non-removability of cover, cover plate or starting element", the suspension section in this paragraph was changed to 17.6.1, the title "Overview" was added,

The original 17.5.1 was changed to 17.6.2, the original 17.5.2 was changed to 17.6.3, the original 17.6 was changed to 17.7, and the title "force requirements" was added; the original

17.7 was changed to 17.8, and the heading "10N Force" was added. The original 17.8 was changed to 17.9, and the heading "Cap or Cover Outline

Line inspection ";

* The suspension section in Chapter 18 was changed to 18.1, the original 18.1 was changed to 18.2, the original 18.2 was changed to 18.3, and the original 18.3 was changed to 18.4.

The technical differences between this part and IEC 62094-1..2002 and their causes are as follows.

--- Regarding the normative reference documents, this section has made adjustments with technical differences to adapt to China's technical conditions and the situation of adjustment.

The situation is reflected in Chapter 2 "Regulatory Reference Documents", and the specific adjustments are as follows.

* Replaced IEC 60112 with GB/T 4207 equivalent to the international standard;

* Replaced IEC 60529 with GB/T 4208-2017 equivalent to the international standard;

* Replaced IEC 60695-2-10..2000 with GB/T 5169.10 equivalent to the international standard;

* Replaced IEC 60695-2-11..2000 with GB/T 5169.11 equivalent to the international standard;

* Replaced IEC 60212 with GB/T 10580 equivalent to the international standard;

* Replaced IEC 60998 (all parts) with GB/T 13140 (all parts) equivalent to the international standard;

* Replaced IEC 60061 (all parts) with GB/T 19148 (all parts) that adopted the international standard.

--- About the use of ambient temperature modification. Chapter 1 of IEC 60669-1..2007 provides.

Suitable for use in ambient temperatures that normally do not exceed 25 ° C, but occasionally reach 35 ° C. Considering the geographical position of our country

Location, actual natural climate and environmental temperature distribution, the south of the Yangtze River is located in the sub-humid tropical zone and the annual average temperature

And the highest temperature is higher and the humidity is greater. Therefore, the operating environment temperature is changed to. "The indicator device that meets the requirements of this section is suitable for

It is used in an environment that usually does not exceed 35 degrees C and occasionally reaches 40 degrees C. "

--- For additional testing of thermoplastic materials or elastic materials, 10.1 of IEC 62094-1..2002 stipulates. "The shell or cover is a thermoplastic material

The indicator device of plastic or elastic material shall also be subjected to the following additional tests. The test is carried out at an ambient temperature of 35 ° C +/- 2 ° C.

OK, the switch should also be at this temperature. Taking into account the harsh conditions of the use of ambient temperature in China and the use of ambient temperature in Chapter 1

It is stipulated that "35 ° C +/- 2 ° C" be changed to "(40 +/- 2) ° C" correspondingly.

--- Regarding the moisture-proof test, 14.3 of IEC 62094-1..2002 stipulates. "Any temperature of

Convenient value t +/- 1K. Before putting the sample in the humidity chamber, make the sample reach t ~ t 4 degrees C. "Considering that parts of our country are wet

The tropical climate, and the electrical and electronic products in China all use (40 +/- 2) degrees C for humid heat test, so this section provides. "Test chamber

The temperature should be maintained at (40 +/- 2) degrees C. Allow the sample to reach this temperature before placing it in the humid chamber. "This provision is related to

GB/T 2423.3 "Environmental test Part 2. Test method Test Cab. Constant damp heat test" is consistent.

--- 12.2.1 According to the current situation of the product, change the conductor wiring capacity from "1mm2 ~ 2.5mm2" to "0.5mm2 ~

2.5mm2 ".

The following editorial changes have been made in this section.

--- According to the provisions of GB/T 1.1-2009, the "Scope" in Chapter 1 was supplemented by "this part of GB/T 38281 specifies household and

Technical requirements for the structure, electrical performance, and mechanical performance of indicator light devices of similar uses for fixed electrical installations. "

--- Removed notes containing requirements from other countries, such as 12.2.6, 13.23.2 notes.

This section is proposed by China Electrical Equipment Industry Association.

This section is under the jurisdiction of the National Electrical Accessories Standardization Technical Committee (SAC/TC67).

This section was drafted by. China Electrical Appliance Research Institute Co., Ltd., Ningbo Bull Bull Electrical Co., Ltd., Guangdong Honghelang Electric

Co., Ltd., Honeywell Langneng Electrical System Technology (Guangdong) Co., Ltd., Hangzhou Hongyan Electrical Co., Ltd., Tianji Electric (Shenzhen) Co., Ltd.

Division, Guangdong Foton Electric Co., Ltd., Siemens (China) Co., Ltd. Shanghai Branch, Feidiao Electric Group Co., Ltd., TCL-Legrand

International Electric (Huizhou) Co., Ltd., Weikai Testing Technology Co., Ltd., Zhejiang Zhongxun Electronics Co., Ltd., Zhejiang Fangyuan Testing Group

Co., Ltd., Beijing Zhongke Kelaibo Electronic Technology Co., Ltd.

1 Scope

This part of GB/T 38281 specifies the structure, electrical performance, and mechanical characteristics of indicator lamps for household and similar fixed electrical installations.

Mechanical performance and other technical requirements.

This section applies to a stand-alone indicator device intended to provide a visible signal. The device is designed for indoor or outdoor use in homes.

Use and similar fixed electrical devices, only for alternating current, rated voltage does not exceed 440V, rated power does not exceed 10W.

Note 1. The indicator devices within the scope of this section are not used as light sources for lighting [see GB 7000].

This section also applies to installation boxes with indicator units, except for concealed installation boxes with concealed indicator units [according to

GB/T 17466].

This section does not apply to indicators installed on products that meet their own standards, they are to be tested as part of the product.

The indicator device conforming to this section is suitable for use in an ambient temperature that normally does not exceed 35 ° C and occasionally reaches 40 ° C.

Special structures may be required in places with special conditions, such as ships, vehicles, and dangerous places where explosions may occur.

Note 2. LEDs and lights are not considered as indicator devices, only as components.

2 Normative references

The following documents are essential for the application of this document. For dated references, only the dated version applies to this article

Pieces. For undated references, the latest version (including all amendments) applies to this document.

GB/T 4207 Method for determination of tracking resistance index and comparative tracking index of solid insulation materials (GB/T 4207-2012,

(IEC 60112..2009, IDT)

GB/T 4208-2017 enclosure protection level (IP code) (IEC 60529..2013, IDT)

GB/T 5169.10 Fire hazard test for electric and electronic products-Part 10. Basic test method for glow wire/hot wire

And general test methods (GB/T 5169.10-2017, IEC 60695-2-10..2013, IDT)

GB/T 5169.11 Fire hazard test for electric and electronic products. Part 11. Glow wire/hot wire basic test method.

Hot Wire Flammability Test Method (GWEPT) (GB/T 5169.11-2017, IEC 60695-2-11..2014, IDT)

GB/T 10580 Standard conditions used before and during testing of solid insulation materials (GB/T 10580-2015, IEC 60212.

(2010, IDT)

GB/T 13140 (all parts) Connecting devices for household and similar low-voltage circuits [IEC 60998 (all parts)]

GB/T 16842-2016 Test tool for protection and inspection of housing and people (IEC 61032..1997, IDT)

GB/T 19148 (all parts) Type and size of lamp holder [IEC 60061 (all parts)]

3 terms and definitions

The following terms and definitions apply to this document.

Note. Unless otherwise specified, where the terms "voltage" and "current" are used, they refer to their rms value (root mean square value).

3.1

Indicator light unit indicatorlightunit

A device with a terminal or end (such as a connector) that is not used as a light source and gives a visible signal with weak light.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

IEC 60112 · IEC 60529 · GB/T 5169.10 · GB/T 5169.10-2017 · IEC 60695 · GB/T 5169.11 · GB/T 5169.11-2017 · GB/T 10580 · GB/T 10580-2015 · IEC 60212 · GB/T 13140 · IEC 60998 · GB/T 16842-2016 · IEC 61032 · GB/T 19148 · IEC 60061

How to Buy GB/T 38281.1-2019

  1. 1Add to cart. Click the "Buy GB/T 38281.1-2019" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 38281.1-2019

$810.00

$690.00for partners