GB/T 37751.33-2019Residual current operated circuit-breakers for household and similar use -- Part 3-3: Specific requirements for RCDs with screw-type terminals for external untreated aluminium conductors and with aluminium screw-type terminals for use with copper or with (English PDF)
Also coversGBT37751.33-2019
Open the GB/T 37751.33-2019 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
June 4, 2019
Implementation date
January 1, 2020
Scope
GB/T 37751.33-2019 (Residual current operated circuit-breakers for household and similar use -- Part 3-3: Specific requirements for RCDs with screw-type terminals for external untreated aluminium conductors and with aluminium screw-type terminals for use with copper or with) is available as an English-translated PDF.
GB/T 37751.33-2019 — This part of GB/T 37751 applies to threaded terminals with untreated aluminum conductors or aluminium with copper or aluminium conductors. The RCD of the threaded terminal block. Threaded terminal blocks for connecting untreated aluminum conductors are made of copper or contain at least 58% Made of copper (cold worked) or copper alloy containing at least 50% copper (other processed), or with corrosion resistance not lower than copper and with suitable machine Mechanical properties of other metals or coated metals. This part cannot be used alone and must be used in conjunction with the RCD product standard (IEC 61008-1 or IEC 61009-1) for external connection. Threaded terminal block for untreated aluminum wire and aluminum threaded terminal block for connecting copper or aluminum wire. In this section, copper-plated, nickel-plated aluminum conductors are considered aluminum conductors.
Document preview — GB/T 37751.33-2019
National Standard of the People's Republic of China
- ICS
- 29.120.50
- Classification
- K 31
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
Foreword
GB/T 37751 "Residual current operated circuit breakers for household and similar purposes" is divided into the following sections.
--- Part 1. Overview of independent modules and unit modules for residual current electrical standards (GB/T 37751.1);
--- Part 2. Residual current electrical appliances (RCD) vocabulary (GB/T 37751.2);
--- Part 3-1. Particular requirements for RCDs with non-threaded terminals to be connected to external copper conductors (GB/T 37751.31);
--- Part 3-2. Particular requirements for RCDs with flat quick-connect ends (GB/T 37751.32);
---Part 3-3. Threaded terminal blocks with external untreated aluminium conductors and aluminium threaded connection to copper or aluminium conductors
Special requirements for type terminal block RCD (GB/T 37751.33).
This part is part 3-3 of GB/T 37751.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This section uses the translation method equivalent to IEC 62873-3-3.2016 "Residual current operated circuit breakers for household and similar purposes"
Part 3-3. Threaded terminal blocks with external untreated aluminum conductors and aluminium threaded terminals with copper or aluminium conductors
Special requirements for sub-RCD.
The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows.
---GB/T 16916.1-2014 Residual current operated circuit breaker (RCCB) without overcurrent protection for household and similar purposes
Part 1. General rules (IEC 61008-1.2012, MOD);
---GB/T 16917.1-2014 Residual current operated circuit breaker (RCBO) with overcurrent protection for household and similar purposes
Part 1. General rules (IEC 61009-1.2012, MOD);
--- GB/T 37751.2-2019 Residual current operated circuit breakers for household and similar purposes - Part 2
(RCD) vocabulary (IEC 62873-2.2016, IDT).
This section has made the following editorial changes.
--- Deleted the original note in Chapter 1, the content of which has nothing to do with China;
--- Table 4 "Connectable wires and their theoretical diameter" Note in the reference file "ASTM B172-01a" is incorrect, changed to
"ASTMB172-17" is also modified accordingly in the references.
This part was proposed by China Electrical Equipment Industry Association.
This part is under the jurisdiction of the National Low Voltage Electrical Appliance Standardization Technical Committee (SAC/TC189).
This section drafted by. Shanghai Electric Apparatus Research Institute, Zhejiang Zhengtai Electric Co., Ltd., Zhongshan Kaipu Electric Co., Ltd., Su
State Shangdian Electric Equipment Co., Ltd.
1 Scope
This part of GB/T 37751 applies to threaded terminals with untreated aluminum conductors or aluminium with copper or aluminium conductors.
The RCD of the threaded terminal block. Threaded terminal blocks for connecting untreated aluminum conductors are made of copper or contain at least 58%
Made of copper (cold worked) or copper alloy containing at least 50% copper (other processed), or with corrosion resistance not lower than copper and with suitable machine
Mechanical properties of other metals or coated metals.
This part cannot be used alone and must be used in conjunction with the RCD product standard (IEC 61008-1 or IEC 61009-1) for external connection.
Threaded terminal block for untreated aluminum wire and aluminum threaded terminal block for connecting copper or aluminum wire.
In this section, copper-plated, nickel-plated aluminum conductors are considered aluminum conductors.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
IEC 61008-1 Residual current operated circuit-breakers (RCCB) without overcurrent protection for household and similar purposes - Part 1. 1
General rule [Residualcurrentoperatedcircuit-breakers without integralovercurrentprotectionfor
Householdandsimilaruses(RCCBs)-Part 1.Generalrules]
IEC 61009-1 Residual current operated circuit breakers (RCBO) with overcurrent protection for household and similar purposes - Part 1. General
Rule [Residualcurrentoperatedcircuit-breakerswithintegralovercurrentprotectionforhouseholdand
Similaruses(RCBOs)-Part 1.Generalrules]
Residual current operated circuit breakers for household and similar purposes - Part 2. Residual current electrical appliances (RCD) vocabulary [Re-
Sidualcurrentoperatedcircuit-breakersforhouseholdandsimilaruses-Part 2.Residualcurrentde-
Vices(RCDs)-Vocabulary]
3 Terms and definitions
The following terms and definitions as defined by IEC 62873-2 apply to this document.
3.1
Treated wire treatedconductor
The contact portion of the wire, the oxide layer on the outer layer of the strand is erased, and/or the compound is added to improve the bonding ability and/or corrosion resistance.
ability.
3.2
Untreated wire untreated/unpreparedconductor
A wire that has been cut and stripped of the insulating layer in order to insert the terminal.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
IEC 61008 · IEC 61009
How to Buy GB/T 37751.33-2019
- 1Add to cart. Click the "Buy GB/T 37751.33-2019" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 37751.1-2019 — Residual current operated circuit-breakers for household and similar use -- Part 1: Outline of blocks and modules for residual current devices standard
GB/T 37751.2-2019 — Residual current operated circuit-breakers for household and similar use -- Part 2: Residual current devices (RCDs) -- Vocabulary
GB/T 37751.31-2019 — Residual current operated circuit-breakers for household and similar use -- Part 3-1: Particular requirements for RCDs with screwless-type terminals for external copper conductors
Secure payment via Stripe
Payments accepted
GB/T 37751.33-2019
$190.00