GB/T 37751.31-2019Residual current operated circuit-breakers for household and similar use -- Part 3-1: Particular requirements for RCDs with screwless-type terminals for external copper conductors (English PDF)
Also coversGBT37751.31-2019
Open the GB/T 37751.31-2019 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
June 4, 2019
Implementation date
January 1, 2020
Scope
GB/T 37751.31-2019 (Residual current operated circuit-breakers for household and similar use -- Part 3-1: Particular requirements for RCDs with screwless-type terminals for external copper conductors) is available as an English-translated PDF.
GB/T 37751.31-2019 — This part of GB/T 37751 is applicable to RCDs with unthreaded terminals with rated current not exceeding 20A. The terminal blocks are mainly used to connect untreated (see 3.5) copper conductors with a cross-sectional area of 4 mm2. This section cannot be used alone. For RCDs with unthreaded terminals, this part and the RCD product standard (IEC 61008-
Document preview — GB/T 37751.31-2019
National Standard of the People's Republic of China
- ICS
- 29.120.50
- Classification
- K 31
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 1 Scope
- 1 or IEC 61009-1) used together.
- 2 Normative references
- 3 Terms and definitions
Foreword
GB/T 37751 "Residual current operated circuit breakers for household and similar purposes" is divided into the following sections.
--- Part 1. Overview of independent modules and unit modules for residual current electrical standards (GB/T 37751.1);
--- Part 2. Residual current electrical appliances (RCD) vocabulary (GB/T 37751.2);
--- Part 3-1. Particular requirements for RCDs with non-threaded terminals to be connected to external copper conductors (GB/T 37751.31);
--- Part 3-2. Particular requirements for RCDs with flat quick-connect ends (GB/T 37751.32);
---Part 3-3. Threaded terminal blocks with external untreated aluminium conductors and aluminium threaded connection to copper or aluminium conductors
Special requirements for type terminal block RCD (GB/T 37751.33).
This part is part 3-1 of GB/T 37751.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This section uses the translation method equivalent to IEC 62873-3-1.2016 "Residual current operated circuit breakers for household and similar purposes 3-1"
Part. Special requirements for RCDs with unthreaded terminal blocks for external copper conductors.
The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows.
---GB/T 16916.1-2014 Residual current operated circuit breaker (RCCB) without overcurrent protection for household and similar purposes
Part 1. General rules (IEC 61008-1.2012, MOD);
---GB/T 16917.1-2014 Residual current operated circuit breaker (RCBO) with overcurrent protection for household and similar purposes
Part 1. General rules (IEC 61009-1.2012, MOD);
--- GB/T 37751.2-2019 Residual current operated circuit breakers for household and similar purposes - Part 2
(RCD) vocabulary (IEC 62873-2.2016, IDT).
This section has made the following editorial changes.
--- Deleted the original note in the first note in Chapter 1, the original note in 3.2, and the second half of the original note 2 in 9.3.2, whose content has nothing to do with China;
--- Table 1 "Connectable wires" Note in the reference file "ASTMB172-01a" is incorrect, changed to "ASTMB172-17", the same
It is modified accordingly in the reference.
This part was proposed by China Electrical Equipment Industry Association.
This part is under the jurisdiction of the National Low Voltage Electrical Appliance Standardization Technical Committee (SAC/TC189).
This section drafted by. Shanghai Electric Apparatus Research Institute, Zhejiang Zhengtai Electric Co., Ltd., Zhongshan Kaipu Electric Co., Ltd., Shi
Ned Electric (China) Co., Ltd. Shanghai Branch.
1 Scope
This part of GB/T 37751 is applicable to RCDs with unthreaded terminals with rated current not exceeding 20A.
The terminal blocks are mainly used to connect untreated (see 3.5) copper conductors with a cross-sectional area of 4 mm2.
This section cannot be used alone. For RCDs with unthreaded terminals, this part and the RCD product standard (IEC 61008-
1 or IEC 61009-1) used together.
In this section, the non-threaded terminal block is called a terminal block, and the copper wire is called a wire.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
IEC 61008-1 Residual current operated circuit-breakers (RCCB) without overcurrent protection for household and similar purposes - Part 1. 1
General rule [Residualcurrentoperatedcircuit-breakers without integralovercurrentprotectionfor
Householdandsimilaruses(RCCBs)-Part 1.Generalrules]
IEC 61009-1 Residual current operated circuit breakers (RCBO) with overcurrent protection for household and similar purposes - Part 1. General
Rule [Residualcurrentoperatedcircuit-breakerswithintegralovercurrentprotectionforhouseholdand
Similaruses(RCBOs)-Part 1.Generalrules]
Residual current operated circuit breakers for household and similar purposes - Part 2. Residual current electrical appliances (RCD) vocabulary [Re-
Sidualcurrentoperatedcircuit-breakersforhouseholdandsimilaruses-Part 2.Residualcurrentde-
Vices(RCDs)-Vocabulary]
3 Terms and definitions
The following terms and definitions as defined by IEC 62873-2 apply to this document.
3.1
Clamping unit clampingunits
The components necessary for mechanical clamping and electrical connection of the conductors in the terminals, including the components necessary to ensure normal contact pressure.
3.2
Universal terminal block universalterminal
Terminal block for connecting and removing all type conductors (hard and soft).
3.3
Non-universal terminal block non-universalterminal
Used only to connect and disconnect certain wires [for example, only for hard solid wires or terminals for hard (solid or stranded) wires only].
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
IEC 61008 · IEC 61009
How to Buy GB/T 37751.31-2019
- 1Add to cart. Click the "Buy GB/T 37751.31-2019" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 37751.1-2019 — Residual current operated circuit-breakers for household and similar use -- Part 1: Outline of blocks and modules for residual current devices standard
GB/T 37751.2-2019 — Residual current operated circuit-breakers for household and similar use -- Part 2: Residual current devices (RCDs) -- Vocabulary
GB/T 37751.32-2019 — Residual current operated circuit-breakers for household and similar use -- Part 3-2: Particular requirements for RCDs with flat quick-connect terminations
Secure payment via Stripe
Payments accepted
GB/T 37751.31-2019
$190.00