GB/T 37637-2019Performance requirements for LED floodlights (English PDF)
LED投光灯具性能要求
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 37637-2019 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
June 4, 2019
Implementation date
January 1, 2020
Scope
GB/T 37637-2019 is the English-translated version of LED投光灯具性能要求.
GB/T 37637-2019 is the Chinese standard "Performance requirements of LED floodlights". Its scope clause reads: This Standard specifies performance requirements for floodlights of which power supply voltage does not exceed 1000V, and LED is used as light source (hereinafter referred to as "lights").
This Standard is applicable to lights that are used in architecture, landscapes, works of art, public places, sports venues. This Standard is not applicable to lights of which half peak angle is less than 2° (such as searchlight).
This Standard does not involve lights that use LED lights covered in GB/T 31897.1-2015. Its clauses include terms and definitions; classification of lights; general requirements; general test requirements and conditions; technical requirements; test methods.
It was issued by the State Administration for Market Regulation on JUNE 04, 2019 and took effect on JANUARY 01, 2020.
Found what you need?
Document preview — GB/T 37637-2019
National Standard of the People's Republic of China
- ICS
- 29.140.40
- Classification
- K 73
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions5
- 4 Classification of lights6
- 5 General requirements7
- 6 General test requirements and conditions7
- 7 Technical requirements10
- 8 Test methods15
1 Scope
This Standard specifies performance requirements for floodlights of which power supply voltage does not exceed 1000V, and LED is used as light source (hereinafter referred to as "lights").
This Standard is applicable to lights that are used in architecture, landscapes, works of art, public places, sports venues.
This Standard is not applicable to lights of which half peak angle is less than 2° (such as searchlight).
This Standard does not involve lights that use LED lights covered in GB/T 31897.1-2015.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 2423.17, Environmental testing for electric and electronic products - Part 2: Test method - Test Ka: Salt mist (GB/T 2423.17-2008, IEC 60068-2-11:1981, IDT)
GB 7000.1-2015, Luminaires - Part 1: General requirements and tests (IEC 60598-1:2014, IDT)
GB/T 7002, Photometry for floodlight
GB/T 10682-2010, Double-capped fluorescent lamps - Performance specifications
GB 17625.1, Electromagnetic compatibility - Limits - Limits for harmonic current emissions (equipment input current <=16 A per phase) (GB 17625.1-2012, IEC 61000-3-2:2001, IDT)
GB/T 17743, Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment (GB 17743-2017, CISPR 15:2015, IDT) GB/T 24823-2017.
4 Classification of lights
4.2 Lights can be classified into white lights and color lights (non-white lights).
4.3 Lights can be classified into light-output non-adjustable lights (hereinafter referred to as "non-adjustable lights") and light-output adjustable lights (hereinafter referred to as "adjustable lights").
NOTE: Light-output adjustable lights might be dynamic dimming.
4.4 White lights can be classified into color-temperature non-adjustable lights and color-temperature adjustable lights.
4.5 Color lights can be classified into color non-adjustable lights and color adjustable lights.
NOTE: Color adjustable lights might be dynamic coloring.
5 General requirements
5.1 Lights shall meet safety requirements and electromagnetic compatibility requirements specified in IEC 60598-2-5:2015, GB/T 17743, GB 17625.1 and GB/T 18595.
5.2 Lights shall provide claimed functions and achieve claimed performances under rated conditions.
6 General test requirements and conditions
6.1 General test requirements
6.1.1 All tests in this Standard are type tests.
6.1.2 All samples that each test item specifies number of samples shall meet requirements of this Standard. In order to shorten test time, producer (manufacturer) or responsible seller can additionally submit lights or light components that have same material and same design with lights under test.
The premise is that test results are same as those on same lights.
6.2 General test conditions
6.2.1 This Standard follows test conditions for photoelectric characteristics of lights given in Annex A of GB/T 31897.201-2016.
6.2.2 Burn-in time before testing is 0h or burn-in time is not less than 500h that is put forward by manufacturer.
- replacement method.
7 Technical requirements
7.1.2.3 Rated luminous flux or rated luminous flux at maximum input power (such as dimming and coloring lights and dynamic dimming and coloring lights).
7.1.2.4 For color lights, following information shall be provided:
- about initial rated color coordinate value, for dynamic coloring and (or) dynamic coloring lights, it shall mark rated color coordinate value under maximum rated input power;
- for color lights of which color remains unchanged, it shall indicate light color, for example, green light or red light.
7.1.2.5 For white lights, following information shall be provided:
- rated correlated color temperature (CCT, K) and claimed color tolerance.
For lights that color temperature is adjustable, it shall claim that one or more color temperature values required by color tolerance can be met;
- rated color rendering index Ra and R9. For lights that color temperature is adjustable, if color rendering index changes with color temperature, it needs to indicate color rendering index corresponding to correlated color temperature.
7.1.2.6 It shall provide beam spread or one half-peak divergence, peak light intensity and light intensity distribution map of lights.
7.1.2.7 Use lights of control device of independent light that is separated from light source chamber. It shall provide electrical parameters of driving light source or model specifications of applicable control device as well as corresponding producer (manufacturer). For lights that use control device of built-in light, it shall provide model specifications of control device used as well as corresponding producer (manufacturer).
7.1.2.8 For lights that use replaceable LED module, following information shall be provided:
- applicable LED module model specifications, photometric codes and their corresponding producers (manufacturers);
7.1.2.9 For dimming lights, it shall provide relevant information such as dimming control mode.
7.1.2.10 For lights that angle is adjustable, it shall indicate adjustment range of horizontal and/or vertical direction angle.
7.2 Input power
Protection level of enclosures of outdoor lights and external electrical cavity shall reach IP65.
7.6 Salt-spray corrosion resistance
For outdoor lights, after salt-spray corrosion resistance test, metal enclosures and external components shall not show any signs of damage, rust, erosion or corrosion.
7.7 Luminous maintenance rate
Type A lights do not have to provide sample for this test. Maintenance value under rated value claimed by module tp can be also called as maintenance value of lights under tq.
Type B lights need to carry out this test. Test cycle is 25% of rated life, not exceeding 6000h at most.
In addition to following requirements, lights shall meet requirements of 10.2 in GB/T 24823-2017.
- Ambient temperature of maintenance rate test shall be within performance temperature range (rated tq-2, rated tq).
- During testing, LED module in lights shall not exceed maximum rated temperature tp.
Measured lumen maintenance rate shall not be less than rated lumen maintenance rate code corresponding to lumen maintenance rate.
For dynamic dimming and coloring lights, luminous maintenance rate is not required.
7.8 Correlated color
temperature, color rendering index and chromaticity coordinates
7.8.1 Correlated color temperature (white lights)
Deviation BETWEEN measured chromaticity coordinate initial value and 6000h maintenance value AND standard chromaticity coordinate value of rated correlated color temperature shall not exceed claimed color tolerance. Annex D of GB/T 10682-2010 specifies calculation methods for standard chromaticity coordinate values of 7 sets specific chromaticity coordinates as well as tolerance range. Producer (manufacturer) may manufacture lights of other chromaticity coordinates according to user or market demand. However, it shall also give chroma coordinate target values and tolerance ranges for non-standard colors simultaneously.
NOTE: Annex A of GB/T 31897.1-2015 gives regional standard information of acceptable photometric data format.
8 Test methods
8.3.3 Angle of spread
Measure according to requirements of GB/T 7002.
8.3.4 Peak light intensity
Measure according to requirements of GB/T 7002.
8.4 Angle positioning
8.4.1 Reproducibility
Use the method that positions laser sighting device on lights to inspect compliance. Place light exit surface of laser on center line of illuminating surface of lights (parallel to axis of rotation of lights). Spot angle of laser spot of laser sighting device falling on wall shall not exceed 6 mrad.
Place light exit surface of lights facing the wall. Light exit surface is 3m away from wall surface. Keep lights in a freely rotating state. Use angle positioning device to arbitrarily position on some rotation angle scale. Mark center position A of laser point on wall. Unlock positioning device. Rotate lights within entire adjustable range. Then make positioning device position once more. Do nothing else. Mark center position B of laser point. Measure AB spacing that shall not exceed 1cm. Respectively test in horizontal and vertical rotation directions.
8.4.2 Torsion resistance
Test according to 6.5 of IEC 60598-2-5:2015. After test, mark center position C of laser point. Distance between point A and point C in 8.4.1 shall not exceed 1cm.
8.5 Protection level of light enclosure
Visually inspect protection level of light mark's enclosure. After durability test of 12.3 in GB 7000.1-2015, carry out test specified in Clause 9 of GB 7000.1-2015 to inspect its compliance.
NOTE: Example needs to be tested is the case where IP rating verified in safety inspection report of lights is not IP65.
8.6 Salt-spray corrosion resistance
Carry out test according to provisions of GB/T 2423.17. Test period is 48h. […]
8.7 Luminous maintenance rate
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.17Environmental testing - Part 2: Test methods - Test Ka: Salt mist
- GB 7000.1-2015Luminaires -- Part 1: General requirements and tests
- GB/T 7002Photometry for floodlight
- GB/T 10682-2010Double-capped fluorescent lamps -- Performance specifications
- GB 17625.1Electromagnetic compatibility - Limits - Part 1: Limits for harmonic current emissions(equipment input current <=16 A per phase)
- GB/T 17743Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
Similar standards
How to Download GB/T 37637-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 17625.1-2022 — Electromagnetic compatibility - Limits - Part 1: Limits for harmonic current emissions(equipment input current <=16 A per phase)
GB 7000.1-2015 — Luminaires -- Part 1: General requirements and tests
GB/T 10682-2010 — Double-capped fluorescent lamps -- Performance specifications
Secure payment via Stripe
Payments accepted
GB/T 37637-2019
$135.00