GB/T 37015.1-2018Performance of high-voltage direct current power transmission system using voltage sourced converters (VSC-HVDC)—Part1: Steady-state (English PDF)
柔性直流输电系统性能 第1部分:稳态
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 37015.1-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 28, 2018
Implementation date
July 1, 2019
Scope
GB/T 37015.1-2018 is the English-translated version of 柔性直流输电系统性能 第1部分:稳态.
GB/T 37015.1-2018 is Part 1 of the Chinese standard on the performance of HVDC transmission systems using voltage sourced converters (VSC-HVDC), and deals with steady-state performance from the point of view of power system safety and stability.
It covers adaptability to the AC system (AC voltage, negative sequence current, frequency, power quality, grid strength and short-circuit current), basic design requirements for the converter topology, main wiring and AC and DC field equipment, converter and DC system operating modes, the control system, reliability and losses.
It applies to back-to-back, point-to-point and multi-terminal systems built only with modular multilevel converters, and can guide the planning, design, construction and operation of such systems.
Annexes show typical submodule structures, the main station equipment and the control system. It was issued on 28 December 2018 and has applied since 1 July 2019.
Found what you need?
Document preview — GB/T 37015.1-2018
National Standard of the People's Republic of China
- ICS
- 29.240.01
- Classification
- F 21
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 operational adaptability
- 4.1 General requirements
- 4.2 AC voltage
- 4.3 Negative sequence current
- 4.4 AC frequency
- 4.5 Power Quality
- 4.6 AC grid strength
- 4.7 AC side short circuit current
- 5 Basic design requirements
- 5.1 General requirements
- 5.2 Requirements for the converter topology
- 5.3 Requirements for Primary System Main Wiring
- 5.4 Requirements for AC and DC field equipment
- 6 mode of operation
- 6.1 General requirements
- 6.2 Inverter operation mode
- 6.3 DC system operation mode
- 7 control system
- 7.1 General requirements
- 7.2 Function
- 7.3 Performance
- 7.4 Structure
- 8 Reliability
- 9 loss
- Appendix A (informative) Modular multilevel converter and its submodule typical structure
- Appendix B (informative) Main equipment of flexible DC converter station
- Appendix C (informative) Flexible DC transmission control system structure
Foreword
GB/T 37015 "Flexible DC Transmission System Performance" is divided into two parts.
--- Part 1. Steady state;
--- Part 2. Transient.
This part is the first part of GB/T 37015.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This part of GB/T 37015 specifies the requirements for the steady-state performance of flexible DC transmission systems from the perspective of safety and stability of the power system.
It includes requirements for operational adaptability, basic design requirements, operating methods, control systems, reliability and loss.
This section applies to the steady-state performance of DC back-to-back, end-to-end, multi-end systems using only modular multi-level voltage source converters.
This section can be used for DC transmission systems using current source converters.
This section can be used to guide the planning, design, construction and operation of flexible HVDC systems.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 13498 HVDC transmission terminology
Determination of GB/T 20989 high voltage DC converter station loss
GB/T 30553 high voltage direct current transmission based on voltage source converter
GB/T 34118 voltage source converter terminology for high voltage DC systems
GB/T 34139 flexible DC transmission converter technical specification
GB/T 35702.1 Voltage source converters for high-voltage DC systems - Part 1. General requirements
GB/T 35702.2 Voltage source converter valve losses for high-voltage DC systems - Part 2: Modular multi-level converters
IEEE1204 DC Access Weak AC System Design Guidelines (GuideforPlanningDCLinksTerminatingatACLo-cationsHavingLowShort-CircuitCapacities)
3 Terms and definitions
GB/T 13498, GB/T 30553, GB/T 34118, GB/T 34139, IEEE1204 and the following terms and definitions apply Used in this document.
3.1 Half-bridge submodule
A submodule consisting of two series switching units and a DC capacitor in parallel.
Note: See Figure A.1 in Appendix A.
3.2 Full bridge submodule
A sub-module consisting of a half-bridge sub-module in parallel with two series-connected switching units.
Note: See Figure A.2.
3.3 Half-bridge modular multilevel converter
The bridge arm is a multi-level converter composed of a plurality of half-bridge sub-modules connected in series.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 13498Terminology for high-voltage direct current (HVDC) transmission
- GB/T 20989Determination of power losses in high-voltage direct current (HVDC) converter stations
- GB/T 30553High-voltage direct current (HVDC) power transmission using voltage sourced converters (VSC)
- GB/T 34118Terminology for voltage-sourced converters ( VSC) for high voltage direct current (HVDC) systems
- GB/T 34139Technical specification of converters for high-voltage direct current (HVDC) transmission using voltage sourced converters (VSC)
- GB/T 35702.1Power losses in voltage sourced converter (VSC) valves for high-voltage direct current (HVDC) systems -- Part 1: General requirements
Similar standards
How to Download GB/T 37015.1-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 13498-2017 — Terminology for high-voltage direct current (HVDC) transmission
GB/T 20989-2017 — Determination of power losses in high-voltage direct current (HVDC) converter stations
GB/T 30553-2023 — High-voltage direct current (HVDC) power transmission using voltage sourced converters (VSC)
Secure payment via Stripe
Payments accepted
GB/T 37015.1-2018
$235.00