GB/T 36244-2018Inductively coupled plasma atomic emission spectrometer (English PDF)

电感耦合等离子体原子发射光谱仪

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 36244-2018 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 7, 2018

Implementation date

November 1, 2018

Scope

GB/T 36244-2018 is the English-translated version of 电感耦合等离子体原子发射光谱仪.

GB/T 36244-2018 deals with inductively coupled plasma atomic emission spectrometers, instruments in which an aerosol of the sample is carried into a plasma and excited, and the elements are identified and measured from the wavelength and relative intensity of the characteristic radiation they emit.

It specifies the terms and definitions, composition and classification, requirements, test methods, inspection rules, and marking, packaging, transport and storage of these instruments, and it defines multi-channel simultaneous instruments.

Among its references are GB 4793.1-2007 and GB/T 34065-2017 for safety, GB/T 18268.1-2010 for electromagnetic compatibility, GB/T 11606-2007 for environmental tests and JJG 768-2005, the verification regulation for emission spectrometers.

It applies to instruments used for qualitative and quantitative elemental analysis. It was issued on 7 June 2018 and has applied since 1 November 2018.

Found what you need?

Document preview — GB/T 36244-2018

National Standard of the People's Republic of China

ICS
71.040.10
Classification
N 53

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This standard specifies the terms and definitions, composition and classification of inductively coupled plasma atomic emission spectrometers, requirements, test methods, and inspections. Rules, signs, packaging, transportation and storage.

This standard applies to qualitative and quantitative analysis of elements using inductively coupled plasma as an excitation source combined with atomic emission spectrometry Inductively coupled plasma atomic emission spectrometry (hereinafter referred to as "instrument").

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest version (including all amendments) applies to this document.

GB/T 191-2008 packaging, storage and transportation logo

Preparation of preparations and products used in GB/T 603 chemical reagent test methods

GB/T 4470 Flame Emission, Atomic Absorption and Atomic Fluorescence Spectrometry Terms

GB 4793.1-2007 Safety requirements for electrical equipment for measurement, control and laboratory use Part 1. General requirements

GB/T 6682 Analysis Laboratory Water Specifications and Test Methods

GB 8702 electromagnetic environmental control limit

GB/T 11606-2007 Analytical instrument environmental test method

GB/T 13384 general technical conditions for mechanical and electrical product packaging

GB/T 18268.1-2010 Electromagnetic Compatibility Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use Part 1. General Requirements

GB/T 23942 Chemical reagents General principles of inductively coupled plasma atomic emission spectrometry

GB/T 34065-2017 Safety requirements for analytical instruments

JJG 768-2005 emission spectrometer verification procedures

3 Terms and Definitions

The following terms and definitions as defined in GB/T 23942, GB/T 4470 and JJG 768-2005 apply to this document.

3.1 Inductively coupled plasma; ICP

The plasma generated by induction excitation by the high-frequency electromagnetic field uses the high-temperature and non-electric field gas regions as the observation area.

3.2 Inductively coupled plasma atomic emission spectrometer

The sample is atomized by an atomizer to form an aerosol, which is carried by the carrier gas into the plasma and evaporated, atomized, excited in a high-temperature inert gas atmosphere. Hair and ionization. When an atom or ion of a measured element is excited, the electron transitions at different energy levels within the atom, and when transitioning from a high energy state to a low energy state Generates characteristic radiation. An instrument for qualitative or quantitative analysis of elements by determining the wavelength and relative intensity of such characteristic radiation.

3.3 Multi-channel simultaneous inductively coupled plasma atomic emission spectrometer

Multi-wavelength channel instrument for simultaneous single line detection.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 36244-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 36244-2018

$205.00