Valid

GB/T 35550-2017Freight thermal containers -- Remote condition monitoring (English PDF)

保温集装箱 远程状态监控

Preview PDF

This is a limited preview

Buy now to download the full PDF (59 pages)

Need quotation for your management?

Get a formal quotation for GB/T 35550-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

December 29, 2017

Implementation date

July 1, 2018

Scope

GB/T 35550-2017 is the English-translated version of 保温集装箱 远程状态监控.

GB/T 35550-2017 — This standard stipulates the information and interface requirements for the remote monitoring of thermal insulation containers so that the central monitoring station can be used by carriers or terminals.

The control system is capable of connecting and exchanging information with remote communication devices manufactured by different manufacturers and configured by other carriers or terminals.

The data recording format and message protocol covered by this standard are applicable to all existing data transmission technologies and also applicable to all ISO standards.

Future technologies for quasi-compatible systems. Chapter 4 of this standard specifies the performance requirements for a remote monitoring system for thermal insulation containers.

Chapter 5 specifies the compatibility requirements for the system. except Unless otherwise specified, all insulation container remote monitoring systems shall comply with the provisions of the various parts of this standard.

Found what you need?

Document preview — GB/T 35550-2017

National Standard of the People's Republic of China

ICS
55.180.10
Classification
A 85

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Remote Status Monitoring System Performance Requirements
  • 4.1 Overview
  • 4.2 Remote Status Monitoring System Requirements
  • 4.2.1 System Configuration
  • 4.2.2 System Function
  • 4.2.3 System Performance
  • 5 System Compatibility Requirements
  • 5.1 Overview
  • 5.2 Communication Protocol
  • 5.2.1 System Interface
  • 5.2.2 Communication Between MMU and MDCU
  • 5.2.3 Communication between MDCU and LRCD
  • 5.2.4 Communication between MDCU and HRCD
  • 5.3 MMU/device communication
  • 5.3.1 Data Head
  • 5.3.2 Other MMU/Device Messages
  • 5.4 Low Rate Physical Requirements - From LDCU to LRCD
  • 5.4.1 Frequency
  • 5.4.2 Modulation Method
  • 5.4.3 Baud Rate
  • 5.4.4 Transmission Mode
  • 5.4.5 Coupling Methods
  • 5.4.6 Receiver Sensitivity
  • 5.4.7 Non-transmitting impedance
  • 5.4.8 Bit Synchronization
  • 5.4.9 Carrier preparation time
  • 5.4.10 LDR Compatibility Out-of-band Filtering
  • 5.5 High Rate Physical Requirements - From HDCU to HRCD
  • 5.5.1 Modulation Method --- Broadband
  • 5.5.2 Transmission Method
  • 5.5.3 Coupling Method
  • 5.5.4 Output/Input Impedance
  • 5.5.5 Power Density Function
  • 5.5.6 Synchronization Method
  • 5.5.7 Demodulation Method
  • 5.5.8 Receiver Sensitivity
  • 5.5.9 Data Link Protocol
  • 5.5.10 "HDR" Compatibility Out-of-Band Filtering Requirements
  • Reference

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard uses the translation method equivalent to the use of ISO 10368:2006 "insulated container remote status monitoring." this standard has made the following editorial changes.

a) For the convenience of use, the title adjustments have been made to 5.2.1;

b) Figure 2, Figure 7, Figure 8, Figure 21, Figure 22, Figure 23, Table 7, Table 18, and 5.4.10, with obvious editorial errors in the source text,

5.5.10 The title has been modified;

c) For the sake of convenience, some of the diagrams retain part of the original English form. Figure 3 retains more English.

This standard is proposed and managed by the National Container Standardization Technical Committee (SAC/TC6).

Introduction

The issuing authority of this document draws attention to the fact that, when the statement is in compliance with this document, it may involve low-rate and high-rate systems as referred to in 5.4 and 5.5.

Use of related patents.

The issuing agency of this document has no position on the authenticity, validity and scope of the patent.

The patent holder has assured the issuing agency of this document that he is willing to work with any applicant on reasonable and non-discriminatory terms and conditions.

Negotiate on licensing of patents. The description of the patent holder has been filed with the issuing agency of this document. Related information can be passed below Contact information is obtained.

For low-rate systems, you can get information from the following companies.

Patent holder. ThermoKing Corporation, Address. 314W90thStreetMinneapolis,Minnesota55420USA for high-speed systems, information can be obtained from the following companies.

Patent Holder. AdaptiveNetworksIncorporated Address. 1505 CommonwealthAve.Suite30Brighton, Massachusetts02135USA Please note that in addition to the above patents, some of the contents of this document may still involve patents. The issuing agency of this document does not undertake to identify these Lee's responsibility.

When the international standard corresponding to this document is revised as the second edition, the material related to the RCD/controller interface has been deleted due to its Line interface has nothing to do. In addition, the data recording format has been omitted in part because it is not used by the industry. Other aspects, in the international standards Based on the first edition, minor additions, deletions, and corrections were made as needed.

Insulation container remote status monitoring

1 Scope

This standard stipulates the information and interface requirements for the remote monitoring of thermal insulation containers so that the central monitoring station can be used by carriers or terminals.

The control system is capable of connecting and exchanging information with remote communication devices manufactured by different manufacturers and configured by other carriers or terminals.

The data recording format and message protocol covered by this standard are applicable to all existing data transmission technologies and also applicable to all ISO standards.

Future technologies for quasi-compatible systems.

Chapter 4 of this standard specifies the performance requirements for a remote monitoring system for thermal insulation containers. Chapter 5 specifies the compatibility requirements for the system. except Unless otherwise specified, all insulation container remote monitoring systems shall comply with the provisions of the various parts of this standard.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article Pieces. For undated references, the latest version (including all amendments) applies to this document.

GB/T 7392-1998 Series 1. Technical requirements and test methods for containers Thermal insulation containers (idtISO 1496-2.1996) Information on ISO 9711-2 container ships Part 2. Telecontainers-Information relatedtocontainersonboardvessels-Part 2: Telexdatatransmission)

3 Terms and Definitions

The following terms and definitions apply to this document.

Remote Communication Devices remotecommunicationsdevice;RCD Part of the refrigerator, using the distribution system of the refrigerator as a data transmission medium, interacts with the central monitoring system (CMCS).

Note 1. See Figure 1 and Figure 2.

Note 2. There are two different types of RCD.

a) sRCD (Discrete Telecommunication Equipment) (see 3.9);

b) iRCD (Integrated Telecommunication Equipment) (see 3.10).

Central monitoring system centralmonitoringandcontrolsystem;CMCS Consists of hardware and software to monitor one or more remote communication devices (RCDs).

Note. A typical system includes at least.

a) operation interface;

b) Main Supervisor (MMU);

c) Power line data connection equipment, such as a multi-rate central controller (MDCU).

Master monitor mastermonitoringunit; MMU A central processor, similar to a computer that contains specific hardware and software, controls the entire remote status monitoring system.

Note. This is an interface between the operator and the network.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 59 pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 7392-1998 · ISO 9711

How to Download GB/T 35550-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
59 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 35550-2017

$800.00