GB/T 35211-2017Measurement of nature gas calorific value - Continuous combustion (English PDF)
天然气发热量的测量 连续燃烧法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 35211-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 29, 2017
Implementation date
July 1, 2018
Scope
GB/T 35211-2017 is the English-translated version of 天然气发热量的测量 连续燃烧法.
GB/T 35211-2017 is the Chinese standard "Measurement of nature gas calorific value - Continuous combustion". Its scope clause reads: This standard specifies the continuous combustion gas calorimeter measurement of natural gas calorific value.
This standard applies to 30MJ/m3 ~ 40MJ/m3 high calorific value of natural gas measurement. Note. When there is a suitable standard gas, the measurement range of high calorific value of natural gas can be expanded. Its clauses include measurement principle; test conditions; material.
Found what you need?
Document preview — GB/T 35211-2017
National Standard of the People's Republic of China
- ICS
- 75.060
- Classification
- E 24
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 measurement principle
- 4 test conditions
- 5 material
- 5.1 standard gas
- 5.2 verification gas
- 6 instruments and equipment
- 6.1 calorific value direct measurement system
- 6.2 gas decompression unit
- 6.3 calorimeter
- 6.4 signal acquisition and processing unit
- 7 Test
- 7.1 Instrument Calibration
- 7.2 Sample Test
- 8 data processing
- 9.1 Repeatability
- 9.2 Uncertainty
- Appendix A (Informative) Standard gas and standard curve example
- Appendix B (informative) Verification gas example
- Appendix C (informative) calorific value example
1 Scope
This standard specifies the continuous combustion gas calorimeter measurement of natural gas calorific value.
This standard applies to 30MJ/m3 ~ 40MJ/m3 high calorific value of natural gas measurement.
Note. When there is a suitable standard gas, the measurement range of high calorific value of natural gas can be expanded.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 5274 Gas analysis Calibration Preparation of mixed gases Weighing
GB/T 11062-2014 Method of calculating calorific value, density, relative density and Wobbe index of natural gas
3 measurement principle
A certain amount of gas, through the wet gas flow meter into the combustion chamber completely burned, and then through the heat exchanger, the heat generated by the combustion
Hand to the absorption medium, making the medium temperature increases. The amount of heat generated by the gas is obtained from the temperature at which the test medium is raised.
In the combustion measurement process, using the same motor driven with a gas and thermal adsorption medium wet flow meter. Flow meter placed in constant
Temperature tank, the water remained stable and controlled at a certain temperature, by regulating the water temperature control gas and combustion air temperature, gas combustion generated
Water vapor condensation into liquid, measured the value of high-calorific gas.
4 test conditions
4.1
Ambient temperature Maintain the room temperature 22.5 °C ~ 24.5 °C, temperature fluctuations of not more than 0.3 °C.
4.2
Water temperature .22.0 °C ~ 23.0 °C, temperature fluctuations of not more than 0.3 °C.
4.3 Relative humidity environment
The range of 40% to 60%, every 4h change of not more than 5%.
5 material
5.1 standard gas
5.1.1 Methane
Purity (mole fraction) is not less than 99.995%.
5.1.2 Determination of calorific value of the standard gas
Prepared according to GB/T 5274 or purchased from the nationally accredited production unit.
Two kinds of standard gases with a heating value greater than that of methane, HH and HL, are required, each of which is a mixture of methane and ethane, where HH is methane (Mole fraction, the same below) 87.7%, ethane 12.3%; HL 93.4% of methane, ethane 6.6%.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 35211-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 35211-2017
$205.00