Valid

GB/T 35090-2018Non-destructive testing—Test method for weak magnetic testing of pipeline (English PDF)

无损检测 管道弱磁检测方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 35090-2018 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 14, 2018

Implementation date

December 1, 2018

Scope

GB/T 35090-2018 is the English-translated version of 无损检测 管道弱磁检测方法.

GB/T 35090-2018 is the Chinese national method for weak magnetic testing of pipelines, a non-destructive technique that reads the magnetic field signals, below 0.1 mT, produced by damage in ferromagnetic pipes.

It is used to find cracks, material loss, perforation and other damage, both by direct inspection of pipes without surface protection or covering layers and by non-excavation inspection of buried pipelines.

It does not cover damage at spiral welds or pipes with a metal coating.

The method summary describes how interference is removed and the data analysed to locate and classify damage, and lists the factors that affect the result, such as operating conditions, regional geomagnetic differences, magnetisation of the pipe, nearby magnetic sources and the distance and attitude of the instrument. It was issued on 14 May 2018 and has applied since 1 December 2018.

Found what you need?

Document preview — GB/T 35090-2018

National Standard of the People's Republic of China

ICS
19.100
Classification
J 04

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Method summary

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This standard specifies a method of pipeline weak magnetic detection, which is used for the magnetic field signal strength of the ferromagnetic material pipeline below 0.1mT. Damage detection, cracks, material loss, perforation and other damage detection.

This standard is applicable to the direct detection of pipelines that do not handle surface protection or cover layers and the non-excavation inspection of buried pipelines. This standard does not apply It is used to detect damage at the spiral weld and is not suitable for pipes with metal coating.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 20737 General Terms and Definitions for Nondestructive Testing

3 Terms and definitions

The terms and definitions defined in GB/T 20737 apply to this document.

4 Method summary

4.1 Detection of weak spatial magnetic field distribution signals caused by pipeline damage during operation, through interference removal, data processing and analysis, the pipeline can be judged The location and type of damage is assessed for damage to the pipeline.

4.2 Features and advantages are as follows.

a) non-contact detection;

b) no need to stop the operation, no need for pigging and other pre-treatment, no need to apply external incentives;

c) have early warning capabilities;

d) Easy to operate and simple, not subject to pipe specs.

4.3 The factors affecting the detection effect are as follows.

a) Pipeline operating conditions, such as pipe size, operating pressure, and time of use, affecting the strength of the magnetic field signal;

b) the difference in geomagnetic fields in different regions;

c) artificial magnetization or degaussing of the pipeline, affecting the accuracy of damage detection;

d) Magnetic field interference outside the pipeline being inspected, such as high voltage lines, ferromagnetic signs, parallel pipes, cross pipes, etc. Field signal extraction difficulty;

e) detecting the own components of the instrument, such as electronic components, ferromagnetic components, etc., to increase the difficulty of extracting the magnetic field signal induced by the damage;

f) the distance between the detecting instrument and the pipe to be inspected, including the vertical lifting distance, the horizontal offset distance, etc., affecting the strength of the measured magnetic field signal;

g) The change of the relative position of the detecting instrument and the pipe to be inspected, such as the change of the buried depth of the pipe, the change of the attitude of the instrument, etc. Quantity accuracy.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 35090-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 35090-2018

$195.00