GB/T 34602-2017Ships and marine technology -- Lifesaving and fire protection -- Atmospheric oil mist detectors for ships (English PDF)
船舶与海上技术 救生与消防 船舶油雾探测器
This is a limited preview
Buy now to download the full PDF (38 pages)
Need quotation for your management?
Get a formal quotation for GB/T 34602-2017 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
October 14, 2017
Implementation date
May 1, 2018
Scope
GB/T 34602-2017 is the English-translated version of 船舶与海上技术 救生与消防 船舶油雾探测器.
GB/T 34602-2017 — This standard specifies the performance requirements, test methods and indicators required for oil mist detectors for marine fire alarm systems.
This standard Fixed oil mist detectors are mainly installed in hydraulic oil, fuel and lubricating oil systems and other premises may cause flammable liquid leaks.
This standard applies to the ship point, inhalation, open or beam oil mist detector design, manufacture and testing, based on other working principles the oil mist detector can be used for reference.
This standard does not apply to specific hazards and explosive environment special detectors.
Found what you need?
Document preview — GB/T 34602-2017
National Standard of the People's Republic of China
- ICS
- 47.020.50
- Classification
- U 23
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Requirements
- 4.1 General Requirements
- 4.2 Consistency
- 4.3 Detector calibration
- 4.4 Cleaning alarm
- 4.5 Display device
- 4.6 Independent detection indicator
- 4.7 Connection with auxiliary equipment
- 4.8 Detachable detector monitoring
- 4.9 Producer adjustment
- 4.10 Site adjustment
- 4.11 Slowly increase the oil mist concentration response
- 4.12 Logo
- 4.13 Operation Manual
- 4.14 Data
- 4.15 Software Control Probe Requirements
- 4.16 Storage content monitoring --- optional features
- 4.17 Suction probe additional requirements
- 5 Test methods
- 5.1 General Requirements
- 5.2 Repeatability
- 5.3 High temperature (operation)
- 5.4 Low temperature (operation)
- 5.5 Alternating hot and humid
- 5.6 Sine vibration (operation)
- 5.7 High pressure
- 5.8 Power parameters fluctuate
- 5.9 Power Transient
- 5.10 Insulation resistance
- 5.11 Electrostatic discharge immunity
- 5.12 RF electromagnetic field radiation immunity
- 5.13 Low frequency conducted immunity
- 5.14 RF field induced conduction disturbance immunity
- 5.15 Electrical Fast Transient Immunity
- 5.16 Surge (impact) immunity
- 5.17 Inhalation detector additional test
- 6 Install
- 7 Test Report
- Appendix A (Normative) Main detector and detector function test calibration
- Appendix B (informative) detector replacement test method example
- Appendix C (Informative) Oil mist generator example
- Appendix D (Informative) Oil mist detector location and installation
- References
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the translation method identical with ISO 16437:2012 "ship and marine life-saving and fire-fighting oil mist detectors." the documents of our country that are consistent with the corresponding international documents that are normative references in this standard are as follows.
--- GB/T 2421.1-2008 Electrical and Electronic Products Environmental Testing Overview and Guidelines (IEC 60068-1:1988, IDT)
--- GB/T 2423.1-2008 Environmental testing for electric and electronic products Part 2. Test methods Test A. Low temperature (IEC 60068-2-1:2007, IDT)
--- GB/T 2423.2-2008 Environmental testing for electric and electronic products Part 2. Test methods Test B. High temperature (IEC 60068-2-2:2007, IDT)
--- GB/T 2423.4-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Db. Alternating hot and humid (12h 12h cycle) (IEC 60068-2-30:2005, IDT)
--- GB/T 2423.10-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal) (IEC 60068-2-6:1995, IDT) Electromagnetic compatibility test and measurement techniques Electrostatic discharge immunity test (IEC 61000-4-2).
2001, IDT)
--- GB/T 17626.4-2008 Electromagnetic compatibility test and measurement techniques Fast transient impulse group immunity test (IEC 61000-4-4:2004, IDT)
--- GB/T 17626.5-2008 Electromagnetic compatibility test and measurement techniques surge (impact) immunity test (IEC 61000-4-5:2005, IDT)
--- GB/T 17626.6-2008 electromagnetic compatibility test and measurement techniques RF field induced conduction disturbances immunity (IEC 61000-4-6:2006, IDT) this standard proposed by China State Shipbuilding Corporation.
This standard by the National Marine Machinery Standardization Technical Committee (SAC/TC137) centralized.
This standard was drafted unit. China Shipbuilding Industry and Technology Institute of Integrated Technology, Fujian Tianguang Fire Co., Ltd., but Beijing Thai safety equipment Co., Ltd., Guangzhou Yonghong Fire Equipment Co., Ltd., Jianyang Baoxing Power Machinery Co., Ltd., Xi'an Rio Tinto Fire Technology Co., Ltd., Zhoushan City of Quality and Technical Supervision, Inspection and Research Institute, Weichai Heavy Machinery Co., Ltd.
1 Scope
This standard specifies the performance requirements, test methods and indicators required for oil mist detectors for marine fire alarm systems. This standard Fixed oil mist detectors are mainly installed in hydraulic oil, fuel and lubricating oil systems and other premises may cause flammable liquid leaks.
This standard applies to the ship point, inhalation, open or beam oil mist detector design, manufacture and testing, based on other working principles the oil mist detector can be used for reference. This standard does not apply to specific hazards and explosive environment special detectors.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document.
ISO 7240-2 fire detection alarm system Part 2. Control and indicating equipment (Firedetectionandalarmsystems-Part 2: Controlandindicatingequipment) ISO 7240-4 fire detection alarm system Part 4. Energy supply equipment (Firedetectionandalarmsystems-Part 4: Powersupplyequipment) IEC 60068-1 Environmental testing for electric and electronic products Part 1. Overview and guidance (Environmentaltesting - Part 1.
Generalandguidance)
IEC 60068-2-1 Environmental testing for electric and electronic products Part 2. Test methods Test A. Low temperature (Environmentaltes-ting-Part 2-1.Tests-TestA.Cold) IEC 60068-2-2 Environmental testing for electric and electronic products Part 2. Test methods Test B. High temperature (Environmentaltes-ting-Part 2-2.Tests-TestB.Dryheat) IEC 60068-2-6 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal) [Environ-mentaltesting-Part 2-6.Tests-TestFc.Vibration (sinusoidal)] IEC 60068-2-30 Environmental testing for electric and electronic products Part 2. Test methods Test Db. Alternating hot and humid (12h 12h Cycle) [Environmentaltesting-Part 2-30.Tests-TestDb.Dampheat, cyclic (12h 12hcycle)] IEC 61000-4-2 Electromagnetic compatibility test and measurement techniques Electrostatic discharge immunity test compatibility (EMC) -Part 4-2.Testing and measuringtechniques-Electrostaticdischargeimmu-nitytest) IEC 61000-4-4 Electromagnetic compatibility test and measurement techniques Electrical fast transient burst immunity test [Electromagnetic compatibility (EMC) -Part 4-4.Testingandmeasurementtechniques -Electricfasttransient/burst immunitytest] IEC 61000-4-5 Electromagnetic compatibility Test and Measurement Technique Surge (Shock) Immunity Test [Electromagneticcompati-bility (EMC) -Part 4-5.Testingandmeasurementtechniques-Surgeimmunitytest] IEC 61000-4-6 Electromagnetic compatibility Testing and measurement techniques Immunity to conducted disturbances induced by radio-frequency fields [Electromagnetic compatibility (EMC) -Part 4-6.Testing and measuringtechniques-Immunitytoconducteddis-turbances, inducedbyradio-frequencyfields] EN50086-1:1994 Conduit system electrical equipment provisions Part 1. General requirements (Specificationforconduit
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 38 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 7240 · IEC 60068 · IEC 61000
How to Download GB/T 34602-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 34602-2017
$510.00