Valid

GB/T 34387-2017General function test method for valves used with refrigerant (English PDF)

制冷剂用阀门通用性能试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 34387-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

September 29, 2017

Implementation date

April 1, 2018

Scope

GB/T 34387-2017 is the English-translated version of 制冷剂用阀门通用性能试验方法.

GB/T 34387-2017 sets out the general performance test methods for refrigerant valves.

Clause 1 states that the standard specifies the test items, test conditions, equipment, samples, test preparation, test procedures and data processing for the general performance testing of refrigerant valves, which it calls the valve throughout, and that it applies to valves for refrigerants R22, R134a, R407C, R410A, R32, R404A, R290 and other refrigerants.

Clause 3 lists the test items in Table 1: tightness test, internal leakage test, moisture content test, impurity content test, mineral oil content test, chloride content test, flow coefficient C value test, high temperature test, low temperature test, temperature change resistance test, humidity resistance test, salt spray test, brass ammonia resistance test, stainless steel stress corrosion resistance test, vibration test, drop impact test, hydraulic strength test, minimum destructive pressure test and fatigue durability test.

The draft stops immediately after that table and the page gives no table of contents, so the clauses that set the test conditions, the equipment, the samples, the procedures and the data processing are not shown.

Clause 2 cites GB/T 2423.1, GB/T 2423.2, GB/T 2423.3, GB/T 2423.5, GB/T 2423.10, GB/T 2423.17, GB/T 2423.22, GB/T 6283, GB/T 10567.2 and GB/T 17213.9.

The standard carries ICS 27.200 and Chinese classification J73, was proposed by the China Machinery Industry Federation and is kept by the National Refrigeration and Air Conditioning Equipment Standardization Technical Committee (SAC/TC238). It was issued on 29 September 2017 and has applied since 1 April 2018.

Found what you need?

Document preview — GB/T 34387-2017

National Standard of the People's Republic of China

ICS
27.200
Classification
J 73

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Pilot project
  • 6 Chloride content test 13 Brass ammonia resistance test

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This standard specifies the refrigerant valve (hereinafter referred to as the "valve") general performance test pilot projects, test conditions, equipment, Samples, test preparation, test procedures and data processing.

This standard applies to refrigerant R22, R134a, R407C, R410A, R32, R404A, R290 and other refrigerant valves.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 2423.1 Environmental testing for electric and electronic products Part 2: Test methods Test A. Low temperature

GB/T 2423.2 Environmental testing for electric and electronic products Part 2: Test methods Test B. High temperature

GB/T 2423.3 Environmental testing Part 2: Test methods Test Cab. Constant hot and humid test

GB/T 2423.5 Environmental testing for electric and electronic products Part 2: Test methods Test Ea and Guidelines Impact

GB/T 2423.10 Environmental testing for electric and electronic products Part 2: Test methods Test Fc. Vibration (sinusoidal)

GB/T 2423.17 Environmental testing for electric and electronic products Part 2: Test methods Test Ka. Salt spray

GB/T 2423.22 Environmental testing Part 2: Test methods Test N. Temperature changes

GB/T 6283 Determination of moisture content of chemical products Karl Fischer (General Methods)

GB/T 10567.2 copper and copper alloy processing materials residual stress test method Ammonia smoked test method

GB/T 17213.9 industrial process control valves Part 2-3. Flow capacity test procedures

3 Pilot project

The valve general performance test items in Table 1.

Table 1 Test items: 1 tightness test; 2 internal leakage test; 3 moisture content test; 4 impurity content test; 5 mineral oil content test; 6 chloride content test; 7 flow coefficient C value test; 8 high temperature test; 9 low temperature test; 10 temperature change resistance test; 11 humidity resistance test; 12 salt spray test; 13 brass ammonia resistance test; 14 stainless steel stress corrosion resistance test; 15 vibration test; 16 drop impact test; 17 hydraulic strength test; 18 minimum destructive pressure test; 19 fatigue durability test.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 34387-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 34387-2017

$165.00