Scope

GB/T 33708.2-2025 is the English-translated version of 直流电能测量设备 第2部分:间接接入静止式电能表(0.2级、0.5级和1级).

GB/T 33708.2-2025 is the Chinese standard "Electricity metering equipment (DC) - Part 2: Indirect-connected static meters (classes 0.2, 0.5 and 1)". Its scope clause reads: This document specifies newly manufactured indirect current measuring devices for measuring DC power in a DC power grid, with accuracy classes of 0.2, 0.5, and 1.

Type test requirements and test methods for connected static DC energy meters (hereinafter referred to as "meters"). Note 1.Indirect access instruments include two types. voltage and current indirect access and current indirect access.

Note 2.The instruments covered in this document are used to measure DC power in the following fields or similar applications. ---In electric vehicle (EV) charging stations or EV charging infrastructure (e.g., when measured on the DC side); ---In the information technology (IT) server cluster group; ---In low-voltage DC networks in residential or commercial areas (e.g., when measured on the DC side); ---In solar photovoltaic (PV) systems that measure DC power generation; ---DC power supply point for public transportation networks (such as trolleybuses).

This document applies to the following electrical energy measuring equipment. ---A device for measuring and controlling DC power with a voltage not exceeding 1500V; Note 3.For instruments indirectly connected via a DC sensor (voltage divider), if the rated input voltage of the voltage divider is greater than 1500V, only the measuring device is considered as such.

Low-voltage measuring equipment, including combined devices consisting of DC sensors and measuring equipment, is not considered low-voltage measuring equipment. ---Use integrated or separate indicator displays, or meters without indicator displays; ---Except for the indicator display, all functional units (including additional modules) are encapsulated within the same watch case or form a separate watch case. meter; ---Instruments installed on matching sockets or racks. ---Electrical energy measurement is a mandatory function of the instrument, with additional functions being optional.

Note 4.Additional functions typically included in electricity meters include voltage, current, power, power quality parameter measurement, and measurement of other forms of electricity such as water, gas, and heat.

Parameter measurement interface and load control, communication data interface. Requirements for these functions are not covered in this document.

This document does not apply to. ---Instruments with a nominal voltage exceeding 1500V; ---Electromechanical instruments; ---Portable instrument; Note 5.Portable instruments refer to instruments that are not permanently connected. ---Instruments used in locomotives, rolling stock, ships, and aircraft; ---Laboratory and instrumentation testing equipment; ---DC standard energy meter; ---Data interface for instrument registers; ---A matching socket or rack for mounting instruments; --- Additional features provided in the instrument.

Found what you need?

Document preview — GB/T 33708.2-2025

National Standard of the People's Republic of China

ICS
17.220.20
Classification
N 22
Replacing
GB/T 33708-2017

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Preface
  • Introduction
  • 1.Scope
  • 2 Normative References
  • 3.Terms and Definitions
  • 4.Nominal power value
  • 4.1 Voltage
  • 4.2 Current
  • 4.3 Power Consumption
  • 5.Structural Requirements
  • 5.1 General Requirements
  • 5.2 Mechanical Testing
  • 5.3 Window
  • 5.4 Terminals - Terminal Sockets - Protective Conductor Terminals
  • 5.5 Seal
  • 5.6 Measurement value display
  • 5.7 Measurement Value Storage
  • 5.8 Pulse Output
  • 5.9 Electrical Pulse Input
  • 5.10 Auxiliary power supply
  • 5.11 Communication Port
  • 5.12 Voltage Port and Current Port
  • 6.Instrument Identification and Documentation
  • 7.Metrological performance requirements and tests
  • 7.1 General Test Conditions
  • 7.2 Accuracy Verification Method
  • 7.3 Measurement Uncertainty
  • 7.4 Instrument constant test
  • 7.5 Initial Startup Test
  • 7.6 No-load test
  • 7.7 Starting Current Test
  • 7.8 Repeatability Test
  • 7.9 Basic Error
  • 7.10 Error Deviation Limit Caused by Influencing Quantity
  • 7.11 Timing accuracy
  • 7.12 Load current rise and fall variation test
  • 7.13 Repeated Power-On Variation Test
  • 8.Climate and Environmental Requirements
  • 10 Safety Requirements and Tests
  • 11.Measurement performance protection
  • 12 Type Testing

1 Scope

This document specifies newly manufactured indirect current measuring devices for measuring DC power in a DC power grid, with accuracy classes of 0.2, 0.5, and 1.

Type test requirements and test methods for connected static DC energy meters (hereinafter referred to as "meters").

Note 1.Indirect access instruments include two types. voltage and current indirect access and current indirect access.

Note 2.The instruments covered in this document are used to measure DC power in the following fields or similar applications.

---In electric vehicle (EV) charging stations or EV charging infrastructure (e.g., when measured on the DC side);

---In the information technology (IT) server cluster group;

---In low-voltage DC networks in residential or commercial areas (e.g., when measured on the DC side);

---In solar photovoltaic (PV) systems that measure DC power generation;

---DC power supply point for public transportation networks (such as trolleybuses).

This document applies to the following electrical energy measuring equipment.

---A device for measuring and controlling DC power with a voltage not exceeding 1500V;

Note 3.For instruments indirectly connected via a DC sensor (voltage divider), if the rated input voltage of the voltage divider is greater than 1500V, only the measuring device is considered as such.

Low-voltage measuring equipment, including combined devices consisting of DC sensors and measuring equipment, is not considered low-voltage measuring equipment.

---Use integrated or separate indicator displays, or meters without indicator displays;

---Except for the indicator display, all functional units (including additional modules) are encapsulated within the same watch case or form a separate watch case.

meter;

---Instruments installed on matching sockets or racks.

---Electrical energy measurement is a mandatory function of the instrument, with additional functions being optional.

Note 4.Additional functions typically included in electricity meters include voltage, current, power, power quality parameter measurement, and measurement of other forms of electricity such as water, gas, and heat.

Parameter measurement interface and load control, communication data interface. Requirements for these functions are not covered in this document.

This document does not apply to.

---Instruments with a nominal voltage exceeding 1500V;

---Electromechanical instruments;

---Portable instrument;

Note 5.Portable instruments refer to instruments that are not permanently connected.

---Instruments used in locomotives, rolling stock, ships, and aircraft;

---Laboratory and instrumentation testing equipment;

---DC standard energy meter;

---Data interface for instrument registers;

---A matching socket or rack for mounting instruments;

--- Additional features provided in the instrument.

2 Normative references

The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are listed below.

For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.

GB/T 15284 | GB/T 17215.321 | GB/T 34067.2 | GB/T 13850 | GB/T 33708.3 | GB/T 33708.1 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Editions of GB/T 33708.2

EditionTitleRevisionStatus
GB/T 33708.2-2025Electricity metering equipment (DC) - Part 2: Indirect-connected static meters (classes 0.2, 0.5 and 1)current editionCurrent
GB/T 33708-2017Electricity metering equipment (DC) - Part 2: Indirect-connected static meters (classes 0.2, 0.5 and 1)previous editionSuperseded

This page sells the current edition, GB/T 33708.2-2025. Earlier editions are listed for reference only.

How to Download GB/T 33708.2-2025

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 33708.2-2025

$240.00