GB/T 33260.1-2016Capability of detection -- Part 1: Terms and definitions (English PDF)
检出能力 第1部分:术语和定义
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for GB/T 33260.1-2016 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Recommended
Issue date
December 13, 2016
Implementation date
July 1, 2017
Scope
GB/T 33260.1-2016 is the English-translated version of 检出能力 第1部分:术语和定义.
GB/T 33260.1-2016 — This part of GB/T 33260 gives the terms and definitions used to detect the difference between the actual state and the underlying state of the system.
This part is suitable for continuous measurement of continuous scale, as well as the measurement process and a variety of measurement equipment to detect the ability to obtain.
Found what you need?
Document preview — GB/T 33260.1-2016
National Standard of the People's Republic of China
- ICS
- 03.120.30
- Classification
- A 41
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Out of the concept of the concept of capacity
- 2.1 Check out the capacity of the icon
- 2.2 Symbols
Foreword
GB/T 33260 "Detection capability" is divided into the following parts.
Part 1. Terms and definitions;
Part 2. Method for determining the detection limit of linear calibration cases;
- Part 3. Method for determining the critical value of response variables without calibration data;
- Part 4. Comparison of minimum detectable values and given values;
Part 5. Method for determining the detection capability of linear and non - linear calibration cases.
This part is part 1 of GB/T 33260.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part uses the re-drafting method to modify ISO 11843-1.:1997, "Detection Capability Part 1. Terms and Definitions". versus ISO 11843-1.:1997, the main technical content changes as follows.
--- the vertical line in Figure 1 in the basic state and the actual state between the solid line into a dotted line;
--- the scope of the simplified, ISO 11843-1.:1997 in the scope of the text into the standard introduction;
- Define the concept of capability in ISO 11843-1.:1997 as standard Chapter 2, the terms and definitions as Chapter 3 content.
This part of the National Statistical Methods Applied Standardization Technical Committee (SAC/TC21) proposed and centralized.
This part of the drafting unit. China Institute of Standardization, China Testing and Certification Group Co., Ltd., Xiamen Standard & Poor's standardized service limited Company, Beijing University of Technology, Hefei Teachers College, CITIC Daika Co., Ltd.
Introduction
The general concept given in this section, the critical value of the response variable, the critical value of the net state variable, and the minimum detectable value of the net state variable (See 3.9 to 3.11) for a variety of situations, such as the presence or absence of a substance in the material, whether there is fuel in the sample or device, or Geometric deformation in distorted static systems.
The threshold can be obtained from the actual measurement sequence in order to evaluate the unknown state of the system in this sequence, whereas the minimum of the net state variables the detected value as a characteristic value of the measurement method is used to select the appropriate measurement process. To characterize a measurement process, a laboratory or a measurement method, if each correlation level (ie, a measurement sequence, measurement process, laboratory or measurement method) has Appropriate measurement data, you can determine the minimum detectable value. Different measurement sequence, measurement process, laboratory or measurement method of the smallest detectable the value is different.
This part is suitable for continuous measurement of continuous scale and is suitable for the detection process and the detection capability of various measuring devices.
The relationship between the expected value of the response variable and the state variable value can be described by the calibration function. If the response variable or state variable is a vector Value, then this part can be applied to the vector component or component function.
There may be some differences between the terms used in the chemical analysis and the terms in this section. Appendix A gives the general terms and chemical the correspondence between the terms used.
Detection Capability Part 1. Terminology and Definitions
1 Scope
This part of GB/T 33260 gives the terms and definitions used to detect the difference between the actual state and the underlying state of the system.
This part is suitable for continuous measurement of continuous scale, as well as the measurement process and a variety of measurement equipment to detect the ability to obtain.
2 Out of the concept of the concept of capacity
2.1 Check out the capacity of the icon
This section assumes that the net state variable (see 3.4) is not negative and that the calibration function (see 3.6) is strictly monotonically increasing, with no applicability restrictions. Senate See note 1 of 3.9.
Figure 1 shows some of the concepts. The distribution of the response variables in the figure and the calibration function are examples only and do not represent the distribution
There are any restrictions on the particular type. The symbols used in this part of Figure 1 are examples only and do not constitute a normative document in this section.
Figure 1 Calibration function, the critical value of the response variable, the critical value of the net state variable, and the minimum detectable value of the net state variable
2.2 Symbols
Z. state variable.
z0. State variable value in base state.
X. net state variable, X = Z-z0.
xC. the critical value of the net state variable.
xD. the minimum detectable value of the net state variable.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 33260.2-2018Capability of detection -- Part 2: Methodology in the linear calibration case
- GB/T 33260.3-2018Capability of detection -- Part 3: Methodology for determination of the critical value for the response variable when no calibration data are used
- GB/T 33260.4-2018Capability of detection -- Part 4: Methodology for comparing the minimum detectable value with a given value
- GB/T 33260.5-2018Capability of detection -- Part 5: Methodology in the linear and nonlinear calibration cases
How to Download GB/T 33260.1-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 33260.2-2018 — Capability of detection -- Part 2: Methodology in the linear calibration case
GB/T 33260.3-2018 — Capability of detection -- Part 3: Methodology for determination of the critical value for the response variable when no calibration data are used
GB/T 33260.4-2018 — Capability of detection -- Part 4: Methodology for comparing the minimum detectable value with a given value
Secure payment via Stripe
Payments accepted
GB/T 33260.1-2016
$145.00