GB/T 32910.6-2025Data center — Resource utilization — Part 6: Water usage effectiveness (English PDF)

数据中心 资源利用 第6部分:水资源使用效率

Open the GB/T 32910.6-2025 preview as PDF

Preview — first pages of GB/T 32910.6-2025 (full document: 15 pages)

This is a limited preview

Buy now to download the full PDF (15 pages)

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 30, 2025

Implementation date

December 1, 2025

Scope

GB/T 32910.6-2025 is the English-translated version of 数据中心 资源利用 第6部分:水资源使用效率.

GB/T 32910.6-2025 is the Chinese national standard covering how much water a data centre uses for each kilowatt-hour its IT equipment consumes — the boundary that decides which water counts, the split between municipal supply, reclaimed water and the rainwater or condensate recovered on site, the metering of the water and of the IT equipment electricity, the WUE and the evaluation value calculated from them, the efficiency grades, and the disclosure that makes one operator's figure comparable with another's. Part 6 of the series, first edition, with the electrical energy efficiency part GB/T 32910.3-2016 that supplies the IT power term. In force from 1 December 2025. Issued on 30 May 2025, it has been in force since 1 December 2025.

Document preview — GB/T 32910.6-2025

National Standard of the People's Republic of China

ICS
35.020
Classification
L 60

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • PrefaceIII
  • IntroductionIV
  • 1 Scope1
  • 2 Normative references1
  • 3 Terms and Definitions1
  • 4 Abbreviations2
  • 5 Data Center Water Efficiency Level2
  • 6 Data Center Water Use Boundaries2
  • 7 Measurement of WUE and WUEev calculation parameters2
  • 8 Calculation method3
  • 9 Disclosure requirements4
  • References5

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.

This document is part 6 of GB/T 32910 Data Center Resource Utilization. GB/T 32910 has published the following parts.

— Part 1: Terminology;

— Part 2: Key performance indicator setting requirements;

— Part 3: Electrical energy efficiency requirements and measurement methods;

— Part 4: Utilization rate of renewable energy;

— Part 6: Water use efficiency.

Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents.

This document was proposed and coordinated by the National Information Technology Standardization Technical Committee (SAC/TC28).

This document was drafted by: China Electronics Technology Standardization Institute, China Science and Technology (Beijing) Technology Co., Ltd., China Electronics Technology Standards East China Branch of the Institute of Chemical Engineering, Kailuan Construction (Group) Co., Ltd., Qinghai Provincial Development and Reform Commission, Beijing University of Technology, Beijing CESI Technology Development Co., Ltd., China Unicom Qinghai Branch, Huawei Digital Energy Technology Co., Ltd., China Beijing Branch of United Network Communications Co., Ltd., China Electronics Technology Group Corporation, PetroChina Exploration Co., Ltd.

Exploration and Development Research Institute, Yangxin Hongsheng Copper Co., Ltd., China Institute of Metrology, Beijing Tonghe Shiyi Telecommunications Science and Technology Research Institute Co., Ltd.

Company, Zhongguancun Association for the Promotion of Information Industry, Nanjing Jialitu Computer Room Environment Technology Co., Ltd., Zhongtongfu Construction Co., Ltd., Shenzhen Langgerui Industrial Development Co., Ltd., Shanghai Huarui Zhongxin Technology Co., Ltd., State Grid Hubei Electric Power Co., Ltd., Alibaba Cloud Computing Co., Ltd., Zhongshui Zhujiang Planning, Surveying and Design Co., Ltd., Zhonglian Yungang Data Technology Co., Ltd., China Electronics Engineering Design Institute Co., Ltd. LIMITED.

The main drafters of this document are: Zhang Junhua, Lin Li, Yan Wang, Gao Shuchen, Xiao Yang, Liu Haishan, Zhou Feng, Liu Yu, Wei Limei, Jin Chi, Ran Yongming, Li Baoyu, Zhang Jia, Zhou Zhen, Yu Qingyou, Luo Yi, Wang Bin, Yuan Yudong, Lü Tianwen, Xu Haijin, Liu Yibin, Zhu Chen, Deng Zhifu, Tian Haitao, Dai Dangdang, Wang Chuang, Wu Zheng, Zhou Kang, Xiao Tianli, Zhang Xu, Shi Ye.

Introduction

GB/T 32910 “Data Center Resource Utilization” is intended to consist of the following parts.

— Part 1: Terminology. The purpose is to specify common terms and definitions in the field of data center resource utilization.

— Part 2: Key performance indicator setting requirements. The purpose is to specify the setting requirements and description methods of key performance indicators of data centers. Method and use.

— Part 3: Electric energy efficiency requirements and measurement methods. The purpose is to define, measure and calculate the efficiency of electric energy use in data centers. Calculation method, etc.

— Part 4: Renewable energy utilization rate. The purpose is to define and calculate the renewable energy utilization rate of data centers. Law, etc.

— Part 5: Carbon efficiency. The purpose is to specify the definition, measurement method and calculation method of carbon efficiency of data centers.

— Part 6: Water resource efficiency. The purpose is to specify the definition, calculation method and water efficiency of data center water resource efficiency. Grading methods, etc.

Data Center Resource Utilization Part 6: Water use efficiency

1 Scope

This document establishes the water efficiency level and water resource boundary of data centers, and stipulates the relationship between water resource utilization efficiency and water resource utilization efficiency.

The measurement, calculation methods and disclosure requirements for rate evaluation value calculation parameters.

This document is applicable to the calculation of water resource utilization efficiency in data centers, and is also applicable to the analysis of water resource utilization in data centers.

It can be used as a reference for data center design, construction, and operation and maintenance, and as a basis for water efficiency evaluation of data centers.

2 Normative references

GB/T 32910.3-2016

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Data Center

It consists of computer sites (computer rooms), other infrastructure, information system hardware and software, information resources (data) and personnel, as well as corresponding regulations.

An entity composed of degrees.

[Source. GB/T 32910.1-2017, 2.1]

3.2

After treatment, the urban water supply unit provides reusable sewage (wastewater) to customers that meets the water quality requirements for certain purposes.

3.3

The data center collects rainwater, dehumidified water, fuel combustion water and other non-drinking water resources on site, which are self-treated to meet the cooling needs.

Water quality standards and requirements for equipment use and reuse of water.

Note. The water generated by recycling conventional water sources (such as groundwater and tap water) in the data center does not belong to the data center's self-produced recycled water.

3.4

The amount of water that is consumed and lost in various forms in maintaining the normal operation of a data center and cannot return to surface water bodies or underground aquifers.

3.5 [Source. GB/T 32910.3-2016, 3.3]

The total amount of electricity consumed by various information equipment in a data center.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Editions of GB/T 32910.6

EditionTitleRevisionStatus
GB/T 32910.6-2025Data center - Resource utilization - Part 6: Water usage effectivinesscurrent editionCurrent

This page sells the current edition, GB/T 32910.6-2025. Earlier editions are listed for reference only.

How to Buy GB/T 32910.6-2025

  1. 1Add to cart. Click the "Buy GB/T 32910.6-2025" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 32910.6-2025

$200.00

$170.00for partners