GB/T 32910.2-2017Data center—Resource utilization—Part 2: Setting requirement for key performance indicators (English PDF)
数据中心 资源利用 第2部分:关键性能指标设置要求
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 32910.2-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
July 31, 2017
Implementation date
February 1, 2018
Scope
GB/T 32910.2-2017 is the English-translated version of 数据中心 资源利用 第2部分:关键性能指标设置要求.
GB/T 32910.2-2017 sets out how key performance indicators for a data centre are to be established.
As Part 2 of GB/T 32910 it first defines the boundary of the data centre, its physical extent and the equipment inside it, then gives the general requirements for key performance indicators, the way an indicator is described, the use made of it, and worked examples.
It defines data centre energy consumption, data centre energy efficiency, data centre resource utilization key performance, the data centre key performance indicator and data centre resource efficiency.
Annexes present power usage efficiency EEUE and the renewable energy factor REF. It applies to the specification and building of indicators covering the whole life of a data centre, from design and construction to operation and maintenance. It was issued on 31 July 2017 and has applied since 1 February 2018.
Found what you need?
Document preview — GB/T 32910.2-2017
National Standard of the People's Republic of China
- ICS
- 35.020
- Classification
- L 60
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Abbreviations
- 5 data center boundary
- 5.1 Overview
- 5.2 Data center boundaries and key performance indicators
- 5.3 Data center physical range
- 5.4 Data center equipment
- 6 key performance indicators
- 6.1 Overview
- 6.2 General Requirements for Key Performance Indicators
- 6.3 Description of Key Performance Indicators Method
- 6.4 The use of key performance indicators
- 6.5 Examples of Key Performance Indicators
- Appendix A (Informative) Power Efficiency EEUE
- Appendix B (Informative) Renewable Energy Utilization REF
Foreword
GB/T 32910 "Data Center Resource Utilization", is currently intended to include the following sections.
--- Part 1. Terms;
--- Part 2. Key performance indicators set requirements;
--- Part 3. Energy efficiency requirements and measurement methods;
This section GB/T 32910 Part 2.
This section drafted in accordance with GB/T 1.1-2009 given rules.
1 Scope
This part of GB/T 32910 defines the data center boundaries, provides the key performance indicators (KPI) set requirements, description methods, with En route, and gives examples of KPIs.
This section applies to the specification of the data center life cycle (including design, construction, operation and maintenance and other stages) key performance indicators described And build.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.
General specifications for computerized premises GB/T 2887-2011
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Data center energy consumption
The total amount of energy actually consumed by data center equipment or systems over a period of time.
NOTE: The energy sources mentioned in this section generally convert the energy consumed by the equipment or system into electric energy for unitary calculation in kW · h.
3.2 Data center energy efficiency
The ratio of energy output to input in a data center.
Note: The above energy can be converted into electricity for unified calculation.
3.3 Data Center Resource Utilization Key Performance
A series of data accurately reflect the performance of the data center on the utilization of resources.
3.4 Data center key performance indicators
A measure of the utilization of one or more system resources in the data center.
3.5 Data center resource efficiency
The ratio of system or device output to the corresponding resource consumption in a data center.
Note: When calculating resource efficiency, you may be concerned about the different outputs and different resource consumption of different specific systems or devices, so the ratio of output to consumption There may be different units.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 32910.2-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2887-2011 — General specification for computer field
GB/T 32910.1-2017 — Data center—Resource utilization—Part 1: Terminology
GB/T 32910.3-2016 — Data centre - Resource utilization - Part 3: Energy usage effectiveness requirements and measuring methods
Secure payment via Stripe
Payments accepted
GB/T 32910.2-2017
$145.00