Valid

GB/T 3253.5-2008Methods for chemical analysis of antimony and antimony trioxide - Determination of copper content - Flame atomic absorption spectrometric method (English PDF)

锑及三氧化二锑化学分析方法 铜量的测定 火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 3253.5-2008 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

March 31, 2008

Implementation date

September 1, 2008

Scope

GB/T 3253.5-2008 is the English-translated version of 锑及三氧化二锑化学分析方法 铜量的测定 火焰原子吸收光谱法.

GB/T 3253.5-2008 is the Chinese standard "Methods for chemical analysis of antimony and antimony trioxide - Determination of copper content - Flame atomic absorption spectrometric method".

Its scope clause reads: This section provides antimony trioxide and determination of copper content. This section applies to the determination of antimony trioxide and copper content.

Measurement range. 0.0002% to 0.30%. Its clauses include method summary; reagents; instrument.

Found what you need?

Document preview — GB/T 3253.5-2008

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 13
Replacing
GB/T 3254.4-1998

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument

1 Scope

This section provides antimony trioxide and determination of copper content.

This section applies to the determination of antimony trioxide and copper content. Measurement range. 0.0002% to 0.30%.

2 Method summary

Sample with nitric acid or hydrochloric acid and hydrobromic acid dissolved and evaporated to dryness, repeat adding hydrobromide volatile except antimony. In dilute hydrochloric acid medium, using air - B

Alkyne flame atomic absorption spectrometer the absorbance at a wavelength of 324.7nm measured at copper, antimony trioxide and other impurities do not interfere

Determination.

3 Reagents

3.1 commercially available reagents

3.1.1

hydrochloric acid (rho1.19g/mL).

3.1.2

nitrate (rho1.42g/mL).

3.1.3

hydrobromic acid (rho1.50g/mL).

3.2 solution

3.2.1

hydrochloric acid (1 + 1).

3.2.2

nitric acid (1 + 1).

3.3 standard solution

3.3.1 copper standard stock solution

Weigh 1.0000g copper (>=99.99%) in 200mL beaker, add 20mL of nitric acid (3.2.2), heat gently to dissolve completely, boil drive

In addition to oxides of nitrogen, cooled to room temperature. Moved into 1000mL volumetric flask, dilute with water to volume, and mix. 1mL solution containing 1mg of copper.

3.3.2 Copper standard solution

Pipette 10.00mL copper standard stock solution (3.3.1) in 100mL flask, make up 5mL hydrochloric acid was added (3.2.1), diluted with water

To the mark, and mix. This solution 1mL containing 100µg copper.

4 Instrument

Atomic absorption spectrometer, with copper hollow cathode lamp.

Under optimum working conditions for those who can reach the following indicators can be used.

--- Characteristic concentration. a solution in the measurement matrix consistent solution features copper concentration should not exceed 0.10µg/mL.

--- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0%;

With the lowest concentration of standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum

0.5% concentration of the standard average absorbance.

--- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment

Ratio of not less than 0.8.

Atomic absorption spectrometer reference operating conditions.

--- Wavelength 324.7nm;

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of GB/T 3253.5

EditionTitleRevisionStatus
GB/T 3253.5-2008Methods for chemical analysis of antimony and antimony trioxide - Determination of copper content - Flame atomic absorption spectrometric methodcurrent editionCurrent
GB/T 3254.4-1998Methods for chemical analysis of antimony and antimony trioxide - Determination of copper content - Flame atomic absorption spectrometric methodprevious editionSuperseded

This page sells the current edition, GB/T 3253.5-2008. Earlier editions are listed for reference only.

How to Download GB/T 3253.5-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 3253.5-2008

$85.00