GB/T 32517-2024Installation couplers intended for permanent connection in fixed installations (English PDF)
This is a limited preview
Buy now to download the full PDF (39 pages)
Need quotation for your management?
Get a formal quotation for GB/T 32517-2024 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
August 23, 2024
Implementation date
August 23, 2024
Scope
GB/T 32517-2024 (Installation couplers intended for permanent connection in fixed installations) is available as an English-translated PDF.
GB/T 32517-2024 — This document specifies the classification, marking and documentation, dimensions, construction, mechanical properties, Technical requirements such as electrical performance and thermal performance.
This document applies to two-wire to five-wire mounting couplers with or without grounding, with a rated voltage not exceeding 500VAC or DC, rated the rated connection capacity does not exceed 10mm2 and the rated current does not exceed 32A.
It is used for permanent connection of electrical devices. In addition to the power supply voltage, there are additional Mounted couplers with contact voltage are outside the scope of this document.
In this document, a mounting coupler consists of a female connector and a male connector for permanent connection. The clutch is not intended to be connected or disconnected under load, nor is it intended for use except for initial installation and reconfiguration or repair after installation.
This means that the mounted coupler is designed for infrequent connection and disconnection operations. Mounted couplers are not suitable for socket systems or for lighting connection devices that comply with GB/T 31463 (all parts).
(DCL), and lamp support coupler (LSC).
Mounting couplers that meet the requirements of this document are suitable for use in indoor and outdoor locations where the ambient air temperature does not normally exceed the upper limit the temperature should be 40°C and not exceed 35°C on average within 24h, with the lower limit being -5°C. NOTE 1 Additional tests for use in cold climates are given in Annex A. The necessary information is given in the manufacturer's installation instructions.
NOTE 2 For other temperatures, the necessary information is given in the manufacturer's installation instructions. In places with special conditions, such as on ships, vehicles and similar places, as well as dangerous places, such as places where explosions are likely to occur, special Special structure.
Note 3.The installation coupler must be installed by trained or professional personnel. Note 4.See Appendix B for guidance on the use of mounted coupler systems.
Found what you need?
Document preview — GB/T 32517-2024
National Standard of the People's Republic of China
- ICS
- 29.120.99
- Classification
- K 65
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 General requirements
- 5 Test conditions
- 6 Rating
- 7 Categories
- 8 Logo and Documentation
- 9 Hazardous Compatibility
- 10 Protection against electric shock
- 11 Terminals, ends and connecting wires
- 12 Structure
- 13 Prevent harmful solid foreign matter from entering and harmful water from entering
- 14 Insulation resistance and electrical strength
- 15 Contact structure
- 16 Temperature rise
- 17 Breaking capacity
- 18 Force required to separate the components of the mounted coupler
- 19 Cables and their connections 17
- 20 Mechanical strength
- 21 Heat resistance and anti-aging performance
- 22 Screws, current-carrying parts and their connections
- 23 Creepage distance, electrical clearance and insulation distance through
- 24 Resistance to abnormal heat and tracking
- 25 Rust prevention 27
- Appendix A (informative) Additional tests and requirements for mounted couplers for ambient temperatures below -5°C and not less than -45°C
- Appendix B (Informative) User Guide
- Appendix C (Normative) Number of sample groups used in the test and the test procedure for each group
- Appendix D (Normative) Conventional ground continuity test
- Appendix E (Normative) Warning symbols for DC applications
- Appendix F (Normative) Test circuit for temperature rise test
- References
- Figure 1 Cable fixing component test device
- Figure 2 Device for measuring torsion (example)
- Figure 3 Ball pressure test device
- Figure 4 Explanation of "Widget"
- Figure B.1 Example of using a mounted coupler
- Figure B.2 Mounted coupler 31 shown in enlarged area of Figure B.1
- Figure E.1 Symbol "Do not connect or disconnect under load"
- Figure F.1 1P N PE mounted coupler, including N
- Figure F.2 1P N PE mounted coupler, including PE
- Figure F.3 3P N PE mounted coupler, 3 phases with load
- Figure F.4 3P N PE mounted coupler, N and PE with load
- Figure F.5 1P N PE splitter, phase and N with load
- Figure F.6 1P N PE splitter, phase and PE load
- Figure F.7 3P N PE- to 1P N PE splitter, 3-phase load
- Figure F.8 3P N PE- to 1P N PE splitter, N and PE phases carry
- Table 1 Rated voltage of mounted couplers for AC applications
- Table 2 Rated voltage of mounted couplers for DC applications
- Table 3 Classification of mounted couplers
- Table 4 Test current for mounted couplers
- Table 5 Forces applied to cable fixing components
- Table 6 Torques used in tightening and loosening tests
- Table 7 Mounting coupler for power supply system with maximum voltage to ground of 150VAC and rated pulse voltage of 2.5kV
- Table 8 Mounting coupler for power supply system with maximum voltage to ground 300VAC and rated pulse voltage 4.0kV
- Table 9 Single-phase two-wire system 50VDC and single-phase three-wire system 60VDC, rated pulse voltage 0.8kV power supply system
- Mounting coupler
- Table 10 Power supply system with single-phase two-wire system 120VDC and single-phase three-wire system 240VDC, rated pulse voltage 2.5kV
- Mounting coupler
- Table 11 Power supply system with single-phase two-wire system 220VDC and single-phase three-wire system 440VDC, rated pulse voltage 4.0kV
- Mounting coupler
- Table C.1 Number of sample groups
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.
This document replaces GB/T 32517-2016 "Mounted couplers for permanent connections in fixed installations".
Compared with 2016, in addition to structural adjustments and editorial changes, the main technical changes are as follows.
--- Changed the scope of application, added the maximum current of DC mounted coupler and mounted coupler, changed the maximum current of mounted coupler Applicable temperature range (see Chapter 1, Chapter 1 of the 2016 edition);
--- Changed the definition of mounted coupler (see 3.5, 3.5 of the 2016 edition), changed the term terminal block to splitter (see 3.14, 3.10 of the 2016 edition), changed the definition of routine test (see 3.17, 3.13 of the 2016 edition), changed the definition of accessible Definition of (see 3.19, 3.15 of the 2016 edition), added definition of live parts (see 3.22);
--- Changed the general description of the test conditions (see 5.1, 5.1 of the 2016 edition);
--- Added the rated current type of the mounted coupler and the rated voltage of the mounted coupler in DC applications (see 6.1);
--- Added test requirements for rated values (see 6.4);
--- Added the classification of mounted couplers (see Chapter 7);
--- Changed the requirements for marking and documentation of mounted couplers (see Chapter 8, Chapter 8 of the 2016 edition);
--- Increased the connection capacity values of the terminals of the removable wired female and male connectors (see 11.2);
--- Changed the test requirements for protection against harmful water ingress (see 13.3, 13.2 of the 2016 edition);
--- Added the current for temperature rise test of mounted coupler (see Chapter 16);
--- Changed the temperature requirements for the ball pressure test of other insulating material parts of the mounted coupler (see 21.3, 21.3 of the 2016 edition);
--- Increased requirements for creepage distance, electrical clearance and through insulation distance (see Chapter 23);
--- Added warning symbol requirements for DC applications (see Appendix E);
--- The test circuit for temperature rise test has been changed (see Appendix F, Appendix B of the 2016 edition).
This document is modified to adopt IEC 61535:2023 "Mounted couplers for permanent connections in fixed installations".
The technical differences between this document and IEC 61535:2023 and their reasons are as follows.
--- Added "This document specifies the classification, marking and documents, dimensions, structure and (see Chapter 1) to meet the requirements of GB/T 1.1-2020;
--- Added "After this test, the mark should still be clearly visible" (see 8.3) in the marking test to adapt to my country's technical conditions and increase the Operability;
--- Replaced IEC 60998-2-3 (see 11.1.2) with the normative reference GB/T 13140.4 to adapt to my country's technical conditions and added Operability;
--- The normative reference GB/T 4207 replaces IEC 60112 (see Chapter 24) to adapt to my country's technical conditions and increase operability Sex;
--- Replaced IEC 60695-2-11 (see 24.1) with the normative reference GB/T 5169.11 to adapt to my country's technical conditions, and added Operability.
The following editorial changes were made to this document.
---Replaced IEC 60417:2006 with the informative reference GB/T 5465.1-2009 to adapt to my country's technical conditions and increase the Operability;
---Replace IEC 60309 (all parts) with the informative reference GB/T 11918 (all parts) to adapt to my country's technical requirements parts, increasing operability;
---Replaced IEC 60320 (all parts) with the informative reference GB/T 17465 (all parts) to adapt to my country's technical requirements parts, increasing operability;
---Replaced IEC 61995 (all parts) with the informative reference GB/T 31463 (all parts) to adapt to my country's technical requirements parts, increasing operability;
---Replace IEC 60364 (all parts) with the informative reference GB/T 16895 (all parts) to adapt to my country's technical requirements parts, increasing operability;
--- Adjust the order of the appendices according to the order in which they appear in the main text to adapt to my country's technical conditions and increase operability;
--- Deleted the notes in Chapter 4 and 5.1 to adapt to my country's technical conditions and increase operability.
1 Scope
This document specifies the classification, marking and documentation, dimensions, construction, mechanical properties, Technical requirements such as electrical performance and thermal performance.
This document applies to two-wire to five-wire mounting couplers with or without grounding, with a rated voltage not exceeding 500VAC or DC, rated the rated connection capacity does not exceed 10mm2 and the rated current does not exceed 32A. It is used for permanent connection of electrical devices. In addition to the power supply voltage, there are additional Mounted couplers with contact voltage are outside the scope of this document.
In this document, a mounting coupler consists of a female connector and a male connector for permanent connection.
The clutch is not intended to be connected or disconnected under load, nor is it intended for use except for initial installation and reconfiguration or repair after installation.
This means that the mounted coupler is designed for infrequent connection and disconnection operations.
Mounted couplers are not suitable for socket systems or for lighting connection devices that comply with GB/T 31463 (all parts).
(DCL), and lamp support coupler (LSC).
Mounting couplers that meet the requirements of this document are suitable for use in indoor and outdoor locations where the ambient air temperature does not normally exceed the upper limit the temperature should be 40°C and not exceed 35°C on average within 24h, with the lower limit being -5°C.
NOTE 1 Additional tests for use in cold climates are given in Annex A. The necessary information is given in the manufacturer's installation instructions.
NOTE 2 For other temperatures, the necessary information is given in the manufacturer's installation instructions.
In places with special conditions, such as on ships, vehicles and similar places, as well as dangerous places, such as places where explosions are likely to occur, special Special structure.
Note 3.The installation coupler must be installed by trained or professional personnel.
Note 4.See Appendix B for guidance on the use of mounted coupler systems.
2 Normative references
The contents of the following documents constitute essential clauses of this document through normative references in this document.
For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to this document.
GB/T 2423.7-2018 Environmental testing Part 2: Test methods Test Ec. Impact caused by rough operation (mainly used for Equipment type sample) (IEC 60068-2-31:2008, IDT) GB/T 4207 Determination of tracking resistance index and relative tracking index of solid insulating materials (GB/T 4207-2022, IEC 60112:2020, IDT) GB/T 4208-2017 Degrees of protection provided by enclosures (IP code) (IEC 60529:2013, IDT) GB/T 5169.11 Fire hazard tests for electric and electronic products Part 11: Basic test methods for glow wire/hot wire Hot Wire Flammability Test Method (GWEPT) (GB/T 5169.11-2017, IEC 60695-2-11:2014, IDT) GB/T 13140.4 Connecting devices for low voltage circuits for household and similar purposes Part 2: Connecting devices with piercing insulation as separate units Particular requirements for connectors with clamping parts (GB/T 13140.4-2008, IEC 60998-2-3:2002, IDT) GB/T 16842-2016 Test fixture for testing the protection of enclosures against persons and equipment (IEC 61032:1997, IDT) GB/T 16935.1-2023 Insulation coordination for equipment in low voltage systems Part 1: Principles, requirements and tests (IEC 60664-1.
2020, IDT)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 39 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.7-2018Environmental testing - Part 2: Test methods - Test Ec: Rough handling shocks, primarily for equipment-type specimens
- GB/T 4207Method for the determination of the proof and the comparative tracking indices of solid insulating materials
- GB/T 4207-2022Method for the determination of the proof and the comparative tracking indices of solid insulating materials
- GB/T 4208-2017Degrees of protection provided by enclosures (IP code)
- GB/T 5169.11Fire hazard testing for electric and electronic products -- Part 11: Glowing/hot-wire based test methods -- Glow-wire flammability test method for end-products (GWEPT)
- GB/T 5169.11-2017Fire hazard testing for electric and electronic products -- Part 11: Glowing/hot-wire based test methods -- Glow-wire flammability test method for end-products (GWEPT)
IEC 60068 · IEC 60112 · IEC 60529 · IEC 60695 · GB/T 13140.4 · GB/T 13140.4-2008 · IEC 60998 · IEC 61032 · IEC 60664
How to Download GB/T 32517-2024
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16842-2016 — Protection of persons and equipment by enclosures -- Probe for verification
GB/T 16935.1-2023 — Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
GB/T 2423.7-2018 — Environmental testing - Part 2: Test methods - Test Ec: Rough handling shocks, primarily for equipment-type specimens
Secure payment via Stripe
Payments accepted
GB/T 32517-2024