Valid

GB/T 32242.2-2015Equipment for crop protection -- Induction hopper -- Part 2: General requirements and performance limits (English PDF)

植物保护机械 吸入式加药装置 第2部分:一般要求与性能限值

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for GB/T 32242.2-2015 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

December 10, 2015

Implementation date

July 1, 2016

Scope

GB/T 32242.2-2015 is the English-translated version of 植物保护机械 吸入式加药装置 第2部分:一般要求与性能限值.

GB/T 32242.2-2015 — GB/T 32242 provisions of this part of the GB/T 32242.1 - General requirements and performance limits for inhalation dosing device definition.

This section applies to suction-type dosing means for delivery of pesticides and fertilizers on crop protection.

Found what you need?

Document preview — GB/T 32242.2-2015

National Standard of the People's Republic of China

ICS
65.060.40
Classification
B 90

Issued by: Standardization Administration of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 General requirements
  • 4.1 Rated capacity
  • 4.2 Size of the opening
  • 4.3 Prevent internal contamination
  • 4.4 Pharmacy outlet box

Foreword

GB/T 32242 "plant protection machinery inhaled dosing device" is divided into two parts.

--- Part 1. Test methods;

--- Part 2. General requirements and performance limits.

This section GB/T Part of 232,242.

This section drafted in accordance with GB/T 1.1-2009 given rules.

This part redrafted Law Amendment uses ISO 21278-2:2008 "Part 2 plant protection machinery inhaled dosing device.

General requirements and performance limits. " This part of ISO 21278-2:2008 technical differences are.

--- In Chapter 1, "Scope" increased scope of application of the first chapter and complete.

This section also made the following editorial changes.

--- Deleted the reference to international standards.

This part is proposed by China Machinery Industry Federation.

This part of the National Standardization Technical Committee (SAC/TC201) Agricultural machinery centralized.

This section is responsible for drafting unit. China Academy of Agricultural Mechanization Sciences, Modern Agricultural Equipment Co., Ltd.

Introduction

Sprayers primary kits may be connected to a suction-type dosing device, in order to avoid cross-contamination between the pesticide and the operator and the environment Pollution.

Currently, inhaled dosing device on the market that can be obtained mainly in the following two types.

--- Pesticide can be transferred to the inhalation type dosing device inside the sprayer main kits;

--- Can be transported to the pesticide sprayer master kits, and pharmaceutical box has pre-mixed and self-cleaning function of inhaled dosing Means.

This standard applies to verification inhaled dosing device.

Plant protection machinery inhaled dosing device Part 2. General requirements and performance limits

1 Scope

GB/T 32242 provisions of this part of the GB/T 32242.1 - General requirements and performance limits for inhalation dosing device definition.

This section applies to suction-type dosing means for delivery of pesticides and fertilizers on crop protection.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 18678 plant protection - Agriculture spray (control) the rated capacity and processing liquid tank hole diameter (GB/T 18678-2002, eqv ISO 9357:1990) GB/T 20085 plant protection machinery vocabulary (GB/T 20085-2006, ISO 5681:1992, MOD) GB/T 32242.1-2015 plant protection machinery - Part 1 inhaled dosing devices. Test methods (ISO 21278-1.

2008, MOD)

3 Terms and Definitions

Terms and definitions GB/T 20085 and GB/T 32242.1 defined apply to this document.

4 General requirements

4.1 Rated capacity

Rated volume tick mark should be durable, showing a normal job status inhaled dosing device can be safely added to the maximum capacity.

4.2 Size of the opening

The opening size of inhaled dosing device should be met.

--- When filling no pesticide spill;

--- Volume of at least 10L internal medicine barrel cleaning (according to GB/T 32242.1-2015 6.8.2).

4.3 Prevent internal contamination

Inhaled dosing device should be equipped with protective measures to ensure the prevention of foreign matter into the tank when the drug dosing device is not used.

If inhaled dosing device provided with a lid, it should not prevent the inspection and maintenance of the device.

4.4 Pharmacy outlet box

Mixture outlet should not be greater than 20mm diameter ball through.

Inhaled dosing device should enable the operator to fall into the tank is safe to remove the 20mm diameter sphere.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 32242.2-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 32242.2-2015

$85.00