Valid

GB/T 32065.8-2020Environmental test methods for oceanographic instruments—Part 8: Change of temperature test (English PDF)

海洋仪器环境试验方法 第8部分:温度变化试验

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 32065.8-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

November 19, 2020

Implementation date

June 1, 2021

Scope

GB/T 32065.8-2020 is the English-translated version of 海洋仪器环境试验方法 第8部分:温度变化试验.

GB/T 32065.8-2020 is Part 8 of GB/T 32065 and specifies the change of temperature test for oceanographic instruments, used to judge how well an instrument stands up to changing temperature.

It sets the test requirements and the two forms of the test: the stepped temperature change and the rapid temperature change.

The chamber may be a pair of temperature chambers or a multi-chamber thermal shock chamber; the relative humidity inside must stay below 50 per cent, the specimen sits near the centre with at least 15 cm between any of its faces and the chamber wall, and the chamber temperature has to come back to the set value within a tenth of the exposure time.

It cites GB/T 32065.1-2015, GB/T 32065.2-2015 and GB/T 32065.4-2015. It was issued on 19 November 2020 and has applied since 1 June 2021.

Found what you need?

Document preview — GB/T 32065.8-2020

National Standard of the People's Republic of China

ICS
19.040
Classification
A 21

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Test requirements

Foreword

GB/T 32065 "Marine Instrument Environmental Test Method" is planned to be divided into the following parts.

---Part 1: General Provisions;

---Part 2: Low temperature test;

---Part 3: Low-temperature storage test;

---Part 4: High temperature test;

---Part 5: High temperature storage test;

---Part 6: Constant damp heat test;

---Part 7: Alternating damp heat test;

---Part 8: Temperature change test;

---Part 9: Mold growth test;

---Part 10: Salt spray test;

---Part 11: Impact test;

---Part 12: Crash test;

---Part 13: Tilt and swing test;

---Part 14: Vibration test;

---Part 15: Hydrostatic test;

---Part 16: Seawater corrosion test;

---Part 17: Temperature-Humidity-Vibration Comprehensive Test;

---Part 18: Biological attachment test;

--- Part 19: Immersion test.

This part is Part 8 of GB/T 32065.

This section was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This part of GB/T 32065 specifies the test requirements, test method selection, stepped temperature change Chemistry, rapid temperature changes and related information.

This part is suitable for assessing or determining the adaptability of marine instruments under temperature change conditions, and can also be used as the basis for their parts and components. Reference for temperature change environmental test.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated references, the latest version (including all amendments) applies to this document.

GB/T 32065.1-2015 Environmental test methods for marine instruments Part 1: General

GB/T 32065.2-2015 Marine instrument environmental test method Part 2: Low temperature test

GB/T 32065.4-2015 Marine instrument environmental test method Part 4: High temperature test

3 Test requirements

3.1 General requirements

The standard atmospheric conditions for the temperature change test of marine instruments are carried out in accordance with the provisions of 4.2 in GB/T 32065.1-2015; the test samples are safe The installation is carried out in accordance with the provisions of 6.1 in GB/T 32065.1-2015; the test interruption processing is in accordance with the provisions of Chapter 7 in GB/T 32065.1-2015 Regulations proceed.

3.2 Test equipment

3.2.1 The test equipment should comply with the provisions in Chapter 5 of GB/T 32065.1-2015.

3.2.2 The test equipment can be two temperature test chambers (chambers) or a multi-chamber temperature shock test chamber (chamber) meeting the test conditions.

Unless otherwise specified, when the test sample is converted, the temperature in the test box (chamber) should be restored to within 10% of the exposure duration. Set the temperature.

3.2.3 The relative humidity in the test box (chamber) should not exceed 50%.

3.2.4 During the test, the test sample should be close to the center of the test box (chamber), and the minimum distance between any surface and the wall of the corresponding test box (chamber) Should be greater than 15cm.

3.2.5 If the mounting frame or connecting piece is tested together with the test sample, its volume should be included in the test sample volume. When multiple test samples When starting the test, in addition to meeting the requirements of 3.2.4, it should also ensure that the test samples will not interfere with each other.

3.2.6 The test sample should not be directly radiated by any heating and cooling components in the test box (chamber).

3.3 Test severity level

3.3.1 Test temperature

Unless otherwise specified, the temperature change test temperature of marine instruments shall be selected from the following requirements. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 32065.8-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 32065.8-2020

$115.00