GB/T 31230.2-2014Industrial ethernet fieldbus EtherCAT—Part 2: Physical Layer service and protocol specification (English PDF)
工业以太网现场总线EtherCAT 第2部分: 物理层服务和协议规范
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 31230.2-2014 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
September 30, 2014
Implementation date
April 1, 2015
Scope
GB/T 31230.2-2014 is the English-translated version of 工业以太网现场总线EtherCAT 第2部分: 物理层服务和协议规范.
GB/T 31230.2-2014 is the Chinese standard "Industrial ethernet fieldbus EtherCAT—Part 2: Physical Layer service and protocol specification". Its scope clause reads: Relations section 1.1 and IEC standards GB/T 31230 in this section depends on the IEC 61158 series of 12 file types in the corresponding section. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 31230.2-2014
National Standard of the People's Republic of China
- ICS
- 25.040
- Classification
- N 10
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Introduction
- 1 Scope
- 1.1 Relationship with the IEC standard part
- 1.2 Overview
- 2 Normative references
- 3 Terms and definitions
- 3.1 General terms and definitions
- 3.2 EtherCAT terms and definitions
- 4 Symbols and Abbreviations
- 4.1 Symbols
- 4.2 Abbreviations
- 5 Data Link Layer (DLL) - Physical Layer (PhL) interface
- 5.1 Overview
- 6 System Management Interface 9 -PhL
- 6.1 Overview
- 6.2 System Management Interface 10 -PhL
- 7 DCE unrelated sublayer (DIS)
- 7.1 Overview
- 7.2 DIS
- 8 DTE-DCE interface and the MIS specific features
- 8.1 Overview
- 8.2 DTE-DCE interface
- 9 media related sub-layer (MDS)
- 9.1 Overview
- 9.2 MDS. Cable Media
- 10 MDS-MAU interface
- 10.1 Overview
- 11.1 Electrical characteristics
- 11.2 Media specifications
- 11.3 transmission
- References
- 1 Physical Layer Figure generic model
- 3 Protocol Data Unit
- 5 Manchester Encoding Rules
1 Scope
Relations section 1.1 and IEC standards
GB/T 31230 in this section depends on the IEC 61158 series of 12 file types in the corresponding section.
1.2 Overview
This section defines the part of the demand for fieldbus components, but also provides the necessary media and network configuration to ensure compliance with the following requirements.
a) the data integrity of the data link layer error checking before;
b) physical layer interoperability between devices.
Fieldbus physical layer should be in line with the first layer 7-layer model by GB/T 9387 defined, in addition to frame delimitation of certain types of fieldbus
Breaks exist in the physical layer, other type of frame delimiter are present in the data link layer.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 9387 (all parts), Information technology - Open Systems Interconnection - Basic Reference Model
ISO /IEC 8802-3 Information technology - Inter-system communication and information exchange Local and metropolitan area networks Specific requirements - Part 3.
Carrier Sense Multiple Access with Collision Detection (CSMA/CD) Access Method and Physical Layer Specifications (Informationtechnology-
Telecommunicationsandinformationexchangebetweensystems-Localandmetropolitanareanet- works-Specificrequirements-Part 3. Carriersensemultipleaccesswithcolisiondetection (CSMA /
CD) accessmethodandphysicallayerspecifications)
ANSITIA/EIA-644-A low-voltage differential signaling (LVDS) interface to the electrical characteristics of the circuit [ElectricalCharacteristicsof
LowVoltageDifferentialSignaling (LVDS) InterfaceCircuits]
3 Terms and Definitions
GB/T 9387 defined by the following terms and definitions apply to this document.
3.1 General terms and definitions
NOTE. Many types of multiple protocols defined as shared, but not all protocol types are available.
3.1.1 Activities activity
Fieldbus or magnitude of the noise signal input device of the apparatus is higher than the receiver signal threshold phenomenon.
3.1.2 Barrier
In hazardous areas, in order to meet the demand for intrinsically safe current and voltage limiting physical entities.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 31230.2-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 31230.3-2014 — Industrial ethernet fieldbus EtherCAT—Part 3: Data Link Layer service definition
GB/T 31230.1-2014 — Industrial ethernet fieldbus EtherCAT—Part 1: Overview
GB/T 31230.4-2014 — Industrial ethernet fieldbus EtherCAT—Part 4: Data Link Layer protocol specificatiion
GB/T 31230.2-2014
$255.00