Scope

GB/T 30795-2014 is the English-translated version of 食品用洗涤剂试验方法 甲醇的测定.

GB/T 30795-2014 is the Chinese standard "The test method for safety of food detergents - Determination of methanol content". Its scope clause reads: This standard specifies the test method for determining the methanol content in food detergents.

This standard applies to the determination of methanol content in food-grade detergents, and also to the determination of methanol content in non-food-grade detergents.

The detection limit of this standard is 1.2 mg/kg, and the minimum quantitation limit is 5 mg/kg. Its clauses include principle; reagents; apparatus; procedure.

Found what you need?

Document preview — GB/T 30795-2014

National Standard of the People's Republic of China

ICS
71.100.40
Classification
Y 40

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Principle4
  • 4 Reagents4
  • 5 Apparatus5
  • 6 Procedure6
  • 7 Result determination and calculation8
  • 8 Precision8
  • 9 Method limitations8

1 Scope

This standard specifies the test method for determining the methanol content in food detergents.

This standard applies to the determination of methanol content in food-grade detergents, and also to the determination of methanol content in non-food-grade detergents.

The detection limit of this standard is 1.2 mg/kg, and the minimum quantitation limit is

5 mg/kg.

2 Normative references

The following documents are essential for the application of this document. For any dated reference, only the version corresponding to that date applies to this document;

for any undated reference, the latest version (including all amendments) applies to this document.

GB/T 6682 Water for analytical laboratory use - Specification and test methods

3 Principle

After pretreatment, the sample is injected into a gas chromatograph. Due to differences in boiling point or polarity, each component undergoes adsorption and desorption indefinitely in the chromatographic column to achieve effective separation. The components then enter the detector separately, and their contents are calculated by the peak area of each component.

4 Reagents

Unless otherwise specified, only reagents confirmed to be of analytical grade and grade

III water as specified in GB/T 6682 shall be used in the analysis.

4.1

Isopropanol, which shall be verified to be methanol-free under the same gas chromatography conditions before use.

4.2

Anhydrous methanol.

4.3 Methanol standard stock solution

Weigh 10.0 g of anhydrous methanol (accurate to 0.001 g) into a 50 mL beaker, add 20 mL~30 mL of water, transfer to a 1000 mL volumetric flask, dilute to volume with water, and mix well.

4.4 Methanol standard solution (internal standard method)

Transfer 10.0 mL of methanol standard stock solution to a 100 mL volumetric flask using a pipette, dilute to volume with water, and mix well. Then, pipette 10.0 mL of this diluted solution into a 50 mL beaker, accurately add 2.0 mL of isopropanol, stir thoroughly, and store in a stoppered container. The methanol concentration of this standard solution is 1 mg/mL.

NOTE. The methanol standard stock solution shall be prepared in accordance with the product specification limits. For example, if 20.0 g of anhydrous methanol is weighed when preparing the methanol standard stock solution and other procedures remain unchanged, the methanol concentration of the prepared standard solution shall be 2 mg/mL.

4.5 Methanol standard solution (external standard method)

Use a pipette to transfer 1.0 mL, 2.5 mL, 5.0 mL, and 10.0 mL of methanol standard stock solution into 50 mL volumetric flasks, respectively, and dilute to volume with water and mix well. The concentrations of this series of methanol standard solutions are

0.2 mg/mL, 0.5 mg/mL, 1.0 mg/mL, and 2.0 mg/mL.

Inject 1 µL~2 µL of each standard solution into the chromatograph for determination, and plot the standard curve with peak area as the ordinate and solution concentration as the abscissa.

5 Apparatus

5.1 Gas chromatograph

Chromatographic column. stainless steel column with an inner diameter of 3 mm~4 mm and a length of 2 m~3 m; or, a capillary column, such as DB-FFAP.

Stationary phase. porous polymer microspheres of 180 µm~315 µm, such as PoraPakQ and GDX103; or, polar stationary phases, such as modified PEG.

Detector. flame ionization detector.

Carrier gas. nitrogen.

5.2

Microsyringe, 5 µL or 10 µL.

5.3

Soap film flow meter.

5.4

Volumetric flasks, 50 mL, 100 mL, and 1 L.

5.5

Pipettes, 1 mL, 2 mL, 5 mL, and 10 mL.

5.6

Beaker, 50 mL.

5.7

Colorimetric tube, 10 mL.

6 Procedure

6.1 Condition setting

6.1.1 Reference conditions for the packed column

Injection port temperature. 150 °C;

Column temperature. 110 °C~130 °C;

Detector temperature. 150 °C;

Carrier gas flow rate. approximately 40 mL/min.

6.1.2 Reference conditions for the capillary column

Injection port temperature. 160 °C;

Column temperature. Starting from 35 °C, the first stage heating rate is 3.5 °C/min, increasing to 45 °C; the second stage heating rate is 20 °C/min, increasing to 160 °C.

Detector temperature. 160 °C;

Carrier gas flow rate. approximately 40 mL/min;

Split ratio. 1.20.

6.2 Apparatus adjustment

Inject 1 µL~2 µL of standard solution into the chromatograph and record the chromatogram. Adjust the column temperature and carrier gas flow rate appropriately to ensure that the chromatographic peaks of methanol and isopropanol are fully separated (see Figure 1).

QB/T 2738-2023 | GB/T 22731-2022 | GB 26386-2011 | GB/T 26393-2011 | GB/T 30798-2014 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 30795-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 30795-2014

$85.00