GB/T 30701-2014Surface chemical analysis -- Chemical methods for the collection of elements from the surface of silicon-wafer working reference materials and their determination by total-reflection X-ray fluorescence (TXRF) spectroscopy (English PDF)
表面化学分析 硅片工作标准样品表面元素的化学收集方法和全反射X射线荧光光谱法(TXRF)测定
This is a limited preview
Buy now to download the full PDF (14 pages)
Need quotation for your management?
Get a formal quotation for GB/T 30701-2014 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
June 9, 2014
Implementation date
December 1, 2014
Scope
GB/T 30701-2014 is the English-translated version of 表面化学分析 硅片工作标准样品表面元素的化学收集方法和全反射X射线荧光光谱法(TXRF)测定.
GB/T 30701-2014 — This standard specifies the silicon surface of the sample standard work of elemental iron and/or nickel chemical collection methods (vapor phase decomposition of acid droplets or direct Decomposition) and a total reflection X-ray fluorescence spectrometry (TXRF) assay.
NOTE. to use graphite furnace atomic absorption spectroscopy or inductively coupled plasma mass spectrometry instead of total reflection X-ray fluorescence spectroscopy to determine the collected element.
This standard applies to atomic surface density of from 6 × 109atoms/cm2 ~ 5 × 1011atoms/cm2 range of iron and/or nickel.
Found what you need?
Document preview — GB/T 30701-2014
National Standard of the People's Republic of China
- ICS
- 71.040.40
- Classification
- G 04
Issued by: Standardization Administration of China
Contents
- Introduction
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Abbreviations
- 5 Reagent
- 6 Equipment
- 7 Sample preparation and measurement environment
- Preparation 8 calibration sample
- 9 Calibration curve
- 10 Work on standard samples of iron and/or nickel collected
- Determination of the standard work on the 11 samples collected iron and/or nickel
- Precision 9
- 13 Test Report
- Appendix A (informative) international laboratory test results
- Annex B (informative) international laboratory GF-AAS pilot projects and ICP-MS measurements
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses the translation method identical with ISO 17331:2004 "Surface chemical analysis work standard silicon sample surface chemical elements Collection methods and a total reflection X-ray fluorescence spectrometry (TXRF) determination. " this standard incorporates ISO 17331:2010 amendments, the provisions of these amendments has been involved through its external 2004/Amd.1 Vertical wire (||) side margin positions were marked.
The standard micro-beam analysis by the National Standardization Technical Committee (SAC/TC38) and focal points.
This standard was drafted. China Institute of Metrology.
Introduction
In the semiconductor industry, commonly used total reflection X-ray fluorescence spectrometry (TXRF) measuring the wafer surface metal impurities.
ISO 14706 specifies the silicon surface of the metal impurity atoms measuring surface density between 1 × 1010atoms/cm2 ~ 1 × 1014atoms/cm2 Range TXRF method also provides atomic surface density of from 5 × 108atoms/cm2 ~ 5 × 1012atoms/cm2 range Gas Decomposition (VPD).
In VLSI (ULSI) manufacturing, the current very low levels required for wafer surface (less than 1010atoms/cm2) gold Genus impurities measured.
Standard samples with low content of metal impurities in TXRF analysis is important (see ISO 14706), but the service life of standard samples are Limit, especially when considering the surface contamination. Thus, the need for sample preparation of working standards for standardization.
This standard applies to the calculation of the standard and test silicon wafer surface of the metal impurities. Between 9 laboratories in different countries completed Tests showed that this standard method has good reproducibility and repeatability.
Surface chemical analysis work standard silicon sample surface Chemical elements collection methods and a total reflection X-ray Fluorescence Spectrometry (TXRF) Determination
1 Scope
This standard specifies the silicon surface of the sample standard work of elemental iron and/or nickel chemical collection methods (vapor phase decomposition of acid droplets or direct Decomposition) and a total reflection X-ray fluorescence spectrometry (TXRF) assay.
NOTE. to use graphite furnace atomic absorption spectroscopy or inductively coupled plasma mass spectrometry instead of total reflection X-ray fluorescence spectroscopy to determine the collected element.
This standard applies to atomic surface density of from 6 × 109atoms/cm2 ~ 5 × 1011atoms/cm2 range of iron and/or nickel.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
(Trueness and precision) - Part 2 Accuracy GB/T 6379.2-2004 measurement methods and results. the standard measurement to determine the party Method repeatability and reproducibility of the basic method of multiplexing (ISO 5725-2:1994, IDT) ISO 14644-1:1999 Cleanrooms and associated controlled environments - Part 1. Classification of air cleanliness (Cleanroomsand associatedcontroledenvironments-Part 1. Classificationofaircleanliness) ISO 14706:2000 Surface chemical analysis element wafer surface contaminated total reflection X-ray fluorescence spectrometry (TXRF) Determination [Surfacechemicalanalysis-Determinationofsurfaceelementalcontaminationonsiliconwafersby total-reflectionX-rayfluorescence (TXRF) spectroscopy]
3 Terms and Definitions
The following terms and definitions apply to this document.
Working standard samples workingreferencematerial Specified in ISO 14706 for calibration wafers.
Calibration sample calibrationspecimen for calibrating and dried residue containing known amounts of iron and/or nickel silicon.
Calibration solution Preparation of the sample solution for calibration.
Internal standard A known amount of vanadium or scandium, used to normalize the residue iron and the fluorescent X-ray intensity/or nickel.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 5725 · ISO 14644 · ISO 14706
How to Download GB/T 30701-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6379.2-2004 — Measurement methods and results -- Accuracy (trueness and precision) -- Part 2: Determine the standard methods of measurement repeatability and reproducibility of the basic method
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
Secure payment via Stripe
Payments accepted
GB/T 30701-2014
$295.00