GB/T 30412-2013Determination of water vapour transmission rate for plastic film and sheeting -- Humidity detection sensor method (English PDF)
塑料薄膜和薄片水蒸气透过率的测定 湿度传感器法
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for GB/T 30412-2013 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 31, 2013
Implementation date
December 1, 2014
Scope
GB/T 30412-2013 is the English-translated version of 塑料薄膜和薄片水蒸气透过率的测定 湿度传感器法.
GB/T 30412-2013 — This standard specifies a test method for plastic film and sheet water vapor transmission rate was measured by using a humidity sensor. This standard applies to the plastic film, sheet and determination of water vapor transmission rate of multilayer films.
Found what you need?
Document preview — GB/T 30412-2013
National Standard of the People's Republic of China
- ICS
- 83.140.10
- Classification
- G 31
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 5 Sample
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses redrafted Law Amendment uses ISO 15106-1:2003 "Plastics film and sheet water vapor permeability test methods Part 1. Humidity detection sensor method. " this standard and ISO 15106-1:2003 compared to 7.4 in the structure removed and Chapter 12.
This standard and ISO 15106-1:2003 and its technical differences for the following reasons.
--- Remove the 1 in the range of "Notes." To coordinated with several other national standards ISO 15106 transformed in order to avoid Ambiguity.
--- Remove the 2 Normative references in ISO 2528:1995. ISO 2528:1995 does not apply to the scope of the current Plastic film products, and it is not currently subject to national standards adopted.
--- The 7.4 content into 7.2, and the "storage tank" was changed to "the holding plate", the "pump" to "air", while Tester structural example of the figure has also been revised accordingly. Thus test equipment requirements, describes the role and function more clear Clarity, clear, broader applicability.
This standard made the following editorial changes.
--- The standard name was changed to "transmittance measurement of plastic film and sheet water vapor humidity sensor method."
--- The 3.2 reference standard test sample change translated into film.
The standard proposed by China National Light Industry Council.
This standard by the National Plastics Standardization Technical Committee (SAC/TC48) centralized.
This standard was drafted. National Packaging Product Quality Supervision and Inspection Center (Tianjin), Labthink Technology Co., Ltd.
1 Scope
This standard specifies a test method for plastic film and sheet water vapor transmission rate was measured by using a humidity sensor.
This standard applies to the plastic film, sheet and determination of water vapor transmission rate of multilayer films.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6672 plastic film and sheet thickness measurement of the mechanical measurements (GB/T 6672-2001, idt ISO 4593:1993)
3 Terms and Definitions
The following terms and definitions apply to this document.
Water vapor transmission rate watervapourtransmissionrate; WVTR Under certain conditions, the amount of water vapor per unit time through unit area of \u200b\u200bspecimen (g). Expressed in units of grams per square meter per 24 hours [G/(m2 · 24h)].
Standard film referencetestspecimen to calibrate the device using standard film, the film may be a known standard water vapor transmission rate of the film, or obtained by the weight of distilled water standard test method Vapor transmission rate of the film.
Principle 4
Samples separated by a predetermined relative humidity and low humidity chamber having a saturated water vapor at a known temperature and high humidity chamber. Humidity sensor Low humidity chamber at relative humidity measurement, to determine the sample vapor permeable and humidity changes caused, and the measured relative humidity as Electrical signal output, the time required to record the humidity rises to a predetermined value, the sample is used to calculate the water vapor transmission rate.
5 Sample
5.1 sample should be representative, uniform thickness, no wrinkles, creases, pinholes and other defects. Sample area should be larger than the cavity through the area, and can Tightly fixed between the two cavities.
5.2 Unless otherwise specified, take three samples test, the test specimen should be the same machine at the same time.
Sample thickness measuring 5.3 according to the provisions of GB/T 6672, each equidistant uniform sample measuring 3 points.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 30412-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6672-2001 — Plastics film and sheeting - Determination of thickness by mechanical scanning
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
Secure payment via Stripe
Payments accepted
GB/T 30412-2013
$90.00