GB/T 30109-2013AC loss measurements -- Total AC loss measurement of round superconducting wires exposed to a transverse alternating magnetic field at liquid helium temperature by a pickup coil method (English PDF)
交流损耗测量 液氦温度下横向交变磁场中圆形截面超导线总交流损耗的探测线圈测量法
This is a limited preview
Buy now to download the full PDF (24 pages)
Need quotation for your management?
Get a formal quotation for GB/T 30109-2013 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 17, 2013
Implementation date
May 15, 2014
Scope
GB/T 30109-2013 is the English-translated version of 交流损耗测量 液氦温度下横向交变磁场中圆形截面超导线总交流损耗的探测线圈测量法.
GB/T 30109-2013 — This standard specifies the use of coil measurements to detect the alternating magnetic field transverse composite superconducting wire of the total exchange loss methods.
Loss may include Hysteresis loss, coupling loss and eddy current loss. IEC 61788-13 has been described only measure DC magnetic or low magnetic field sweep rate hysteresis loss Consumption standard method [2].
This standard applies to the pulse coil and AC coil metal and oxide superconducting wire circular cross section, time-varying magnetic (time-varying) of Field and/or current applications will produce exchange losses.
In conventional coil applications in electromagnetic field configuration, exchange losses mainly from the (time-varying) magnetic field. For in a horizontal alternating magnetic field of the superconducting wire, the method usually used in liquid helium temperature, frequency range up to the upper limit frequency 50/60Hz Total AC loss measurement.
Adopt the method of measuring the total AC loss superconducting filaments into the hysteresis loss, coupling loss between the wire and often Vortex guide section loss.
In the outer superconducting wire no larger conductor sheath thickness is normal circumstances, exchange losses primarily hysteresis loss and Coupling loss; week since the coupling loss is proportional to frequency, the hysteresis loss in part by the lower frequency range the measured AC loss Loss consumption extrapolated to zero frequency estimate obtained.
Found what you need?
Document preview — GB/T 30109-2013
National Standard of the People's Republic of China
- ICS
- 17.220.20
- Classification
- A 55
Issued by: Standardization Administration of China
Contents
- Introduction
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Principle
- 5 Means
- 5.1 Test apparatus
- 5.2 Detection coil
- 5.3 Compensation circuit
- Sample Preparation 6
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses the translation method is equivalent to using IEC 61788-8Ed.2.2010 "AC loss measurements at liquid helium temperatures transverse alternating magnetic field Circular cross-section superconducting wire coil to detect the total AC loss measurement. " this standard made editorial changes.
Correspondence between the consistency of the standards of international documents and normative references of the following documents.
--- GB/T 13811-2003 Electrotechnical terminology superconductivity (IEC 60050-815:2000, MOD).
This standard by the National Standardization Technical Committee proposed superconductivity.
This standard by the National Standardization Technical Committee superconducting (SAC/TC265) centralized.
Introduction
International Electrotechnical Commission Technical Committee superconducting (IEC/TC90) proposed using a magnetometer and detection coil method to measure a composite superconducting wire in Transverse magnetic field varies with time in exchange losses. They represent a variety of measuring the impact delivered the most common transverse magnetic configuration --- Field Flow of standardized methods loss.
IEC/TC90 decided to split the proposal into two documents were covered by two standard methods. One of them is used to describe the hysteresis loss Consumption and at a low frequency magnetic field (or low field sweep rate) case total AC losses magnetometer measurements; Another method for describing a high-frequency magnetic Detection coil AC loss measurement of the total field (field sweep rate or higher) under. Magnetometer measurement frequency range 0Hz ~ 0.06Hz, Detection coil measurement frequency range of 0.005Hz ~ 60Hz, the overlapping portion (0.005Hz ~ 0.06Hz) are two methods can be used Frequency Range.
This standard relates to the detection coil method. Its ac loss Standard Test Method section refers to advanced materials and standards based on the count of Versailles Plan (VAMAS) in preliminary work on NbTi composite superconductors exchange losses standardized [1].
AC loss measurements at liquid helium temperatures alternating transverse Magnetic field superconducting wire circular cross-section of the total exchange loss Detection coil measurements
1 Scope
This standard specifies the use of coil measurements to detect the alternating magnetic field transverse composite superconducting wire of the total exchange loss methods. Loss may include Hysteresis loss, coupling loss and eddy current loss. IEC 61788-13 has been described only measure DC magnetic or low magnetic field sweep rate hysteresis loss Consumption standard method [2].
This standard applies to the pulse coil and AC coil metal and oxide superconducting wire circular cross section, time-varying magnetic (time-varying) of Field and/or current applications will produce exchange losses. In conventional coil applications in electromagnetic field configuration, exchange losses mainly from the (time-varying) magnetic field. For in a horizontal alternating magnetic field of the superconducting wire, the method usually used in liquid helium temperature, frequency range up to the upper limit frequency 50/60Hz Total AC loss measurement. Adopt the method of measuring the total AC loss superconducting filaments into the hysteresis loss, coupling loss between the wire and often Vortex guide section loss. In the outer superconducting wire no larger conductor sheath thickness is normal circumstances, exchange losses primarily hysteresis loss and Coupling loss; week since the coupling loss is proportional to frequency, the hysteresis loss in part by the lower frequency range the measured AC loss Loss consumption extrapolated to zero frequency estimate obtained.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
IEC 60050-815:2000 Electrotechnical terminology superconductivity [Internationalelectrotechnicalvolcabulary (IEV) -Part 815. Superconductivity]
3 Terms and Definitions
IEC 60050-815:2000 definition of terms and definitions as well as the following terms and definitions apply to this document.
AC loss ACloss
Due to time-varying magnetic field or current composite superconductors in power consumption.
[IEC 60050-815. The 2000815-04-54] 3.2 Hysteresis loss Ph Superconductor in a magnetic field variation of one loss occurs, regardless of their loss of value and frequency of each cycle.
Note. The hysteresis loss by the magnetic flux pinning cause irreversible magnetic superconducting material caused.
[IEC 60050-815. The 2000815-04-55]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 60050
How to Download GB/T 30109-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 30109-2013
$435.00