GB/T 30090-2013Standard guide for temperature electromotive force (emf) tables for non-letter designated thermocouple combinations (English PDF)
无字母代号热电偶分度表
This is a limited preview
Buy now to download the full PDF (45 pages)
Need quotation for your management?
Get a formal quotation for GB/T 30090-2013 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 17, 2013
Implementation date
May 1, 2014
Scope
GB/T 30090-2013 is the English-translated version of 无字母代号热电偶分度表.
GB/T 30090-2013 — This standard specifies no letter code thermocouples special purpose - thermal electromotive force (emf) relationship. This standard applies to special-purpose non-letter code thermocouple. This standard does not apply to extend or compensating leads.
Found what you need?
Document preview — GB/T 30090-2013
National Standard of the People's Republic of China
- ICS
- 17.200.20
- Classification
- N 11
Issued by: Standardization Administration of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Indexing table information
- 4.1 Thermocouple Type
- 4.2 Indexing formula
- 4.3 Inverse indexing formula
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The Standard is a modified ASTM E1751 use the translation method 2000 No letter code combination of temperature thermocouple thermal emf table (Standardguidefortemperatureelectromotiveforce (EMF) tablesfornon-letterdesignatedthermo-couplecombinations).
The standard in the development of the structure of the text made editorial changes.
This standard ASTME1751 technical differences are.
--- Remove the gold - platinum and platinum - palladium two kinds of thermocouples, the remaining 7 kinds of thermocouple was no difference in the technical characteristics of the original standard;
--- Added "2 Normative references" to "Appendix A" "Appendix B";
--- Rewrite "3 Terms and Definitions";
--- Deleted the original "4 Significance and Use" "8 keywords";
--- Original standard "3 Data Sources" "5 thermocouple type" "6 thermal emf - temperature tolerance initial value" of the content of this standard moved Quasi "4 indexing table Information". Also delete the Fahrenheit indexing table indexing formulas and coefficients of each thermocouple. Detailed repair Change the contents of Appendix B.
The standard proposed by China Machinery Industry Federation.
This standard by the national industrial process measurement and control Standardization Technical Committee (SAC/TC124) centralized.
This standard was drafted. Shanghai Industrial Automation Instrument Research Institute, Chongqing Instrument Materials Research Institute, Shanghai Institute of Measurement and Testing Technology, the Sea Automation Instrumentation Co., Ltd., Zhejiang Lunte Electrical Co., Ltd., Zhaoqing Automation Instrumentation Co., Ltd. West Instrument Group Co., Ltd. Company SECRETARY instrument factory, Factory Yueqing City, east China, seventeen Chongqing Sichuan Instrument Co., Ltd., Anhui Rand (Group) Co., Ltd.
1 Scope
This standard specifies no letter code thermocouples special purpose - thermal electromotive force (emf) relationship.
This standard applies to special-purpose non-letter code thermocouple.
This standard does not apply to extend or compensating leads.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 25475 Industrial Automation Instrumentation term Thermometers
3 Terms and Definitions
GB/T 25475 and defined by the following terms and definitions apply to this document.
Matching matchedpairs One pairs of selected positive and negative thermal electrode, constituted by a thermocouple on first use can meet the required temperature - thermal emf relationship and a predetermined tolerance.
4 Indexing table information
4.1 Thermocouple Types
This standard includes the following indexing table.
1) Platinel original EngelhardCorp.SpecialtyMetalsDiv. Trademarks.
2) KP positive hot electrode type K thermocouples.
3) alloy composition expressed as a percentage by mass, with the exception of gold 0.07 iron, which is an atomic percentage.
No. Thermocouple Type Temperature Range
Table 1 Tungsten - rhenium 26 0 °C ~ 2315 °C
Table 2 Platinel1) II 0 °C ~ 1395 °C
Table 3 KP2) - Gold and Iron 0.073) -273 °C ~ 7 °C
Table 5- 4 platinum molybdenum 0.1 0 °C ~ 1600 °C
Table 5 platinum and rhodium 40- platinum and rhodium 20 0 °C ~ 1888 °C
Table 6 nickel-cobalt-nickel-molybdenum 18- 0.8 -50 °C ~ 1410 °C
Table 7 Iridium Iridium rhodium 40- 0 °C ~ 2110 °C
Polynomial coefficients calculated in Table 8 Temperature (°C) thermocouple electromotive force as a function of the
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 45 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 30090-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 25475-2010 — Industrial-process measurement and control instruments - Terminology - Temperature measuring instruments
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
Secure payment via Stripe
Payments accepted
GB/T 30090-2013
$530.00