Valid

GB/T 29515-2013Cold rolled steel sheet for enameling -- Fish-scaling sensitivity test -- Hydrogen permeation method (English PDF)

Also coversGBT29515-2013

Open the GB/T 29515-2013 preview as PDF

Preview — first pages of GB/T 29515-2013

This is a limited preview

Buy now to download the full PDF

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

May 9, 2013

Implementation date

February 1, 2014

Scope

GB/T 29515-2013 (Cold rolled steel sheet for enameling -- Fish-scaling sensitivity test -- Hydrogen permeation method) is available as an English-translated PDF.

GB/T 29515-2013 — This standard specifies the dual cell assay enameling cold-rolled steel scales explosive hydrogen permeation test principle sensitive method, test equipment and electronic Hydrolyzate, samples, test procedures, and test results of the calculation reports. This standard applies to a thickness of 0.3mm ~ 3.0mm enamel sensitivity was measured using cold-rolled steel scales explosion. Principle 2 When charging hydrogen electrolysis, hydrogen ions (H) to reach the surface of the specimen as a cathode, to become a hydrogen atom into the sample, the sample surface to the other diffusion time, Re is a hydrogen atom electrolytically oxidized into hydrogen ions (H), by detecting the anode current of hydrogen oxidation process, to assess the hydrogen atoms in the sample Diffusion process. When the time required for the diffusion of hydrogen called stable hydrogen permeation time tb, tb longer, anti-enamel scale burst performance, the better. by tb defined sample anti-enamel scale explosion sensitivity TH.

Document preview — GB/T 29515-2013

National Standard of the People's Republic of China

ICS
77.040.10
Classification
H 22

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 3 Chemicals
  • 4 test device and the electrolyte
  • 4.1 test device

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

The standard proposed by China Iron and Steel Association.

This standard by the National Steel Standardization Technical Committee (SAC/TC183) centralized.

This standard is drafted by. Wuhan Iron and Steel (Group) Company.

Introduction

Enameling cold-rolled steel scales blast susceptibility testing method generally comprises hydrogen permeation and enamelling law, this standard uses a hydrogen permeation measurement scales steel

Explosion sensitivity.

Enameling cold-rolled steel scales explosion sensitivity test

Hydrogen permeation method

1 Scope

This standard specifies the dual cell assay enameling cold-rolled steel scales explosive hydrogen permeation test principle sensitive method, test equipment and electronic

Hydrolyzate, samples, test procedures, and test results of the calculation reports.

This standard applies to a thickness of 0.3mm ~ 3.0mm enamel sensitivity was measured using cold-rolled steel scales explosion.

Principle 2

When charging hydrogen electrolysis, hydrogen ions (H) to reach the surface of the specimen as a cathode, to become a hydrogen atom into the sample, the sample surface to the other diffusion time,

Re is a hydrogen atom electrolytically oxidized into hydrogen ions (H), by detecting the anode current of hydrogen oxidation process, to assess the hydrogen atoms in the sample

Diffusion process. When the time required for the diffusion of hydrogen called stable hydrogen permeation time tb, tb longer, anti-enamel scale burst performance, the better. by

tb defined sample anti-enamel scale explosion sensitivity TH.

3 Chemicals

Chemicals used in the test were of analytical grade, test water is deionized water.

4 test device and the electrolyte

4.1 test device

Test device shown in Figure 1, the specimen is clamped between two cells A and B are not mutually connected. A termination galvanostat, B termination constant potential

, Automatic recording current variations are oxidized after permeation through the data collection system.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

How to Buy GB/T 29515-2013

  1. 1Add to cart. Click the "Buy GB/T 29515-2013" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 29515-2013

$110.00

$95.00for partners