Scope

GB/T 29031-2012 is the English-translated version of 空气源单元式空调(热泵)热水机组.

GB/T 29031-2012 is the Chinese standard "Air-source based air-conditioning (heat pump) water heater unit".

Its scope clause reads: This standard specifies the source of air-conditioning unit (heat pump) water heaters (hereinafter referred to as "units") terms and definitions, classification and nomenclature, to Requirements, test methods, inspection rules, marking, packaging, transportation and storage.

This standard applies to the motor - compressor drive, using vapor compression refrigeration cycle using air as a heat source, or both at the same time can provide Hot water and indoor air conditioning function (heat pump) water heaters. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 29031-2012

National Standard of the People's Republic of China

ICS
27.200
Classification
J 73

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Classification and Nomenclature
  • 5 Requirement
  • 6 Test Method
  • 7 inspection rules
  • 8 signs, packaging, transportation and storage
  • Appendix A (normative) Static heating air-conditioning units hot water heating capacity performance test methods

1 Scope

This standard specifies the source of air-conditioning unit (heat pump) water heaters (hereinafter referred to as "units") terms and definitions, classification and nomenclature, to

Requirements, test methods, inspection rules, marking, packaging, transportation and storage.

This standard applies to the motor - compressor drive, using vapor compression refrigeration cycle using air as a heat source, or both at the same time can provide

Hot water and indoor air conditioning function (heat pump) water heaters.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 191 Packaging - Pictorial signs

GB/T 4798.1 application of electric and electronic products environmental storage conditions

GB 5296.2 consumer use of household and similar electrical appliances instructions

GB/T 10870-2001 displacement and centrifugal water (heat pump) air conditioner performance test method

GB/T 17758-2010 unit air conditioner

GB/T 18836-2002 duct air-conditioning (heat pump)

GB/T 21362-2008 commercial or industrial use and similar uses heat pump water heater

GB 25130 unit air conditioner security requirements

3 Terms and Definitions

GB/T 17758 and GB/T 21362 and defined by the following terms and definitions apply to this document.

3.1

Air-source air-conditioning unit (heat pump) water heaters (ACWHU) air-sourcebasedair-conditioning (heatpump) water heaterunit

Air as a heat source, with the preparation of domestic hot water heat pump function of the air conditioner unit.

3.2 Cold water-supply capacity (Qcr)

In cooling and hot water preparation test conditions, the cooling capacity of the hot water heating capacity of the unit and the unit. W.

3.3 Cold water-supply power consumption (Wcw)

In cooling and hot water preparation specified test conditions, the total power consumption of the unit, unit. W.

3.4

Cold water-supply coefficient of performance (COPcw) coefficientofperformanceofcombinedcoolingandhot waterheating

In cooling and hot water preparation specified test conditions, cold and hot water-supply capacity of the cold water supply unit associated power consumption ratio, single

Bit. W/W.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 29031-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 29031-2012

$255.00