GB/T 28632-2012Surface chemical analysis -- Auger electron spectroscopy and X-ray photoelectron spectroscopy -- Determination of lateral resolution (English PDF)

Also coversGBT28632-2012

Open the GB/T 28632-2012 preview as PDF

Preview — first pages of GB/T 28632-2012

This is a limited preview

Buy now to download the full PDF

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

July 31, 2012

Implementation date

February 1, 2013

Scope

GB/T 28632-2012 (Surface chemical analysis -- Auger electron spectroscopy and X-ray photoelectron spectroscopy -- Determination of lateral resolution) is available as an English-translated PDF.

GB/T 28632-2012 — This standard specifies the Auger electron spectroscopy and X-ray photoelectron spectroscopy method for measuring the lateral resolution under three conditions. Straight edge Law applies to the lateral resolution is greater than the expected value of the instrument 1µm. Grid method is suitable for the lateral resolution of the expected value is greater than 20nm, less than The instrument 1µm. Golden Island law applies to the lateral resolution is smaller than the expected value of the instrument 50nm. Appendix A, Appendix B and Appendix C gives an example of the measurement of lateral resolution with FIG.

Document preview — GB/T 28632-2012

National Standard of the People's Republic of China

ICS
71.040.40
Classification
G 04

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • 1 Scope1
  • 2 Normative references1
  • 3 Terms, definitions, symbols and abbreviations1
  • 4 General Information2
  • 5 straight edge measured lateral resolution3
  • Measurement of lateral resolution raster 68
  • 7 Golden Island measured lateral resolution10

Foreword

This standard rule according to GB/T 1.1-2009 given draft.

This standard uses the translation method identical with ISO 18516.2006 "Surface chemical analysis - Auger electron spectroscopy and X-ray photoelectron

Determination of lateral resolution spectrum. "

The standard micro-beam analysis by the National Standardization Technical Committee (SAC/TC38) and focal points.

This standard was drafted. Shanghai Measurement and Testing Technology Research Institute, nanotechnology and application National Engineering Research Center.

1 Scope

This standard specifies the Auger electron spectroscopy and X-ray photoelectron spectroscopy method for measuring the lateral resolution under three conditions. Straight edge

Law applies to the lateral resolution is greater than the expected value of the instrument 1µm. Grid method is suitable for the lateral resolution of the expected value is greater than 20nm, less than

The instrument 1µm. Golden Island law applies to the lateral resolution is smaller than the expected value of the instrument 50nm.

Appendix A, Appendix B and Appendix C gives an example of the measurement of lateral resolution with FIG.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article

Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 22461-2008 Surface chemical analysis - Vocabulary (ISO 18115.2001, IDT)

3 Terms, definitions, symbols and abbreviations

3.1 Terms and Definitions

GB/T 22461-2008 defined and the following terms and definitions are applicable to this document.

3.1.1

Lateral resolution resolution, lateral

In the sample surface or a plane within the imaging plane at right angles to the optical axis can be trusted when the composition change region determined points tested distance.

Note 1. The selected plane should be described.

Note 2. In practice, the lateral resolution can be recognized as follows. Strength (i) on a very small sample of the emission points emit distribution half width (FWHM) or (i) along the sample

When the product signal and to distinguish between nature and contain well-defined part of a step function line scan, the intensity of between 12% and 88% points

The distance of the Gaussian intensity distribution, the two values \u200b\u200bare equal. To other distribution, the choice of the other parameters may be more appropriate. For stairs

The distance between the function of scan line spectrum often applied strength distance between 20% and 80% points or 16% and 84%, two points on the Gaussian distribution

Function, the latter pair of the 2sigma width.

GB/T 22461-2008, the definition 5.255

Note 3. For the purposes of this standard, the preferred plane measurement sample.

3.2 Symbols and abbreviations

AES --- Auger electron spectroscopy;

d --- is incident on the sample surface of the electron beam (axial symmetry) beam diameter;

FWHM --- the maximum height of the full width at half (the half-width);

XPS --- X-ray photoelectron spectroscopy;

chi --- lateral resolution required for the measurement parameter; lateral resolution of the measurement starts at the maximum signal strength chi%, at the end of the letter

Maximum signal strength (100-chi)% in deltar under (50) case, chi 25.;

The angle between the incident electron beam or X-ray beam and the surface normal between the upper surface theta --- samples.

GB/T 28632-2012/ISO 18516.2006

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 22461-2008 · ISO 18115.2001

How to Buy GB/T 28632-2012

  1. 1Add to cart. Click the "Buy GB/T 28632-2012" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 28632-2012

$320.00

$270.00for partners