GB/T 28632-2012Surface chemical analysis -- Auger electron spectroscopy and X-ray photoelectron spectroscopy -- Determination of lateral resolution (English PDF)

表面化学分析 俄歇电子能谱和X射线光电子能谱 横向分辨率测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (39 pages)

Need quotation for your management?

Get a formal quotation for GB/T 28632-2012 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

July 31, 2012

Implementation date

February 1, 2013

Scope

GB/T 28632-2012 is the English-translated version of 表面化学分析 俄歇电子能谱和X射线光电子能谱 横向分辨率测定.

GB/T 28632-2012 — This standard specifies the Auger electron spectroscopy and X-ray photoelectron spectroscopy method for measuring the lateral resolution under three conditions.

Straight edge Law applies to the lateral resolution is greater than the expected value of the instrument 1µm. Grid method is suitable for the lateral resolution of the expected value is greater than 20nm, less than The instrument 1µm.

Golden Island law applies to the lateral resolution is smaller than the expected value of the instrument 50nm. Appendix A, Appendix B and Appendix C gives an example of the measurement of lateral resolution with FIG.

Found what you need?

Document preview — GB/T 28632-2012

National Standard of the People's Republic of China

ICS
71.040.40
Classification
G 04

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • 1 Scope1
  • 2 Normative references1
  • 3 Terms, definitions, symbols and abbreviations1
  • 4 General Information2
  • 5 straight edge measured lateral resolution3
  • Measurement of lateral resolution raster 68
  • 7 Golden Island measured lateral resolution10

Foreword

This standard rule according to GB/T 1.1-2009 given draft.

This standard uses the translation method identical with ISO 18516.2006 "Surface chemical analysis - Auger electron spectroscopy and X-ray photoelectron

Determination of lateral resolution spectrum. "

The standard micro-beam analysis by the National Standardization Technical Committee (SAC/TC38) and focal points.

This standard was drafted. Shanghai Measurement and Testing Technology Research Institute, nanotechnology and application National Engineering Research Center.

1 Scope

This standard specifies the Auger electron spectroscopy and X-ray photoelectron spectroscopy method for measuring the lateral resolution under three conditions. Straight edge

Law applies to the lateral resolution is greater than the expected value of the instrument 1µm. Grid method is suitable for the lateral resolution of the expected value is greater than 20nm, less than

The instrument 1µm. Golden Island law applies to the lateral resolution is smaller than the expected value of the instrument 50nm.

Appendix A, Appendix B and Appendix C gives an example of the measurement of lateral resolution with FIG.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated edition applies to this document.

Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 22461-2008 Surface chemical analysis - Vocabulary (ISO 18115.2001, IDT)

3 Terms, definitions, symbols and abbreviations

3.1 Terms and Definitions

GB/T 22461-2008 defined and the following terms and definitions are applicable to this document.

3.1.1

Lateral resolution resolution, lateral

In the sample surface or a plane within the imaging plane at right angles to the optical axis can be trusted when the composition change region determined points tested distance.

Note 1. The selected plane should be described.

Note 2. In practice, the lateral resolution can be recognized as follows. Strength (i) on a very small sample of the emission points emit distribution half width (FWHM) or (i) along the sample

When the product signal and to distinguish between nature and contain well-defined part of a step function line scan, the intensity of between 12% and 88% points

The distance of the Gaussian intensity distribution, the two values are equal. To other distribution, the choice of the other parameters may be more appropriate. For stairs

The distance between the function of scan line spectrum often applied strength distance between 20% and 80% points or 16% and 84%, two points on the Gaussian distribution

Function, the latter pair of the 2sigma width.

GB/T 22461-2008, the definition 5.255

Note 3. For the purposes of this standard, the preferred plane measurement sample.

3.2 Symbols and abbreviations

AES --- Auger electron spectroscopy;

d --- is incident on the sample surface of the electron beam (axial symmetry) beam diameter;

FWHM --- the maximum height of the full width at half (the half-width);

XPS --- X-ray photoelectron spectroscopy;

chi --- lateral resolution required for the measurement parameter; lateral resolution of the measurement starts at the maximum signal strength chi%, at the end of the letter

Maximum signal strength (100-chi)% in deltar under (50) case, chi 25.;

The angle between the incident electron beam or X-ray beam and the surface normal between the upper surface theta --- samples.

GB/T 28632-2012/ISO 18516.2006

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 39 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 28632-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
39 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 28632-2012

$315.00