GB/T 27810-2011Binders for paints and varnishes -- Gel permeation chromatography (GPC) -- Tetrahydrofuran (THF) as eluent (English PDF)
色漆和清漆用漆基 凝胶渗透色谱法(GPC) 用四氢呋喃做洗脱剂
This is a limited preview
Buy now to download the full PDF (19 pages)
Need quotation for your management?
Get a formal quotation for GB/T 27810-2011 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 30, 2011
Implementation date
June 1, 2012
Scope
GB/T 27810-2011 is the English-translated version of 色漆和清漆用漆基 凝胶渗透色谱法(GPC) 用四氢呋喃做洗脱剂.
GB/T 27810-2011 — This standard specifies 1) measured was dissolved in THF (tetrahydrofuran) polymer molecular weight distribution by gel permeation chromatography (GPC), the number average molecular weight Mn and the weight average molecular weight Mw approach.
That the use of this method can obtain good reproducibility, this method can not be specific for certain polymer interaction occurs, for example, Adsorption between the sample/eluent/column system occurred.
This method is not an absolute measurement method should be calibrated using commercially available polystyrene standards unbranched material, and this standard Quality has been measured as obtaining absolute molecular weight.
Therefore, in addition to polystyrene, the measurement results of the polymer sample is used only between the same type of sample group Comparison. The conditions specified in this standard does not apply to a value greater than Mw by GPC analysis of polymer sample 106 (see Appendix C).
This standard without correction methods, such as the elimination of peak broadening. If you want to get the absolute molecular weight value, we need to use an absolute measuring method, for example, Determination of Mn Mw measured by a light scattering method or membrane permeation method.
Found what you need?
Document preview — GB/T 27810-2011
National Standard of the People's Republic of China
- ICS
- 87.040
- Classification
- G 50
Issued by: Standardization Administration of China
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Principle
- 5 Apparatus
- 5.1 General
- Supply 5.2 eluent
- 5.3 Pump
- Injection system 5.4
- 5.5 Column
- 5.6 Column temperature control
- 5.7 Detector
- 5.8 Data Collection
- 6 Eluent
- Instrument calibration 7
- 7.1 General
- 7.2 Calibration with standard material specifications
- 7.3 Calibration injectable solutions prepared with
- 7.4 Calibration operating conditions
- 7.5 Retention volume/time measurement
- 7.6 Draw calibration curve
- 8 Sampling
- 9 7 Test preparation
- 9.1 7 Preparation of injectable solutions of
- Prepare 9.2 Instrument
- 10 Analysis of Condition
- 11 Data acquisition and analysis
- 11.1 General
- 11.2 From the raw data obtained in the chromatogram is calculated net
- Calculate averages 11.3
- Calculation 11.4 distribution curve
- 12 Precision
- 12.1 General
- 12.2 Repeatability
- 12.3 Reproducibility
- 13 11 Test Report
- 13.1 General
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses the translation method identical with the international standard ISO 13885-1:2008 "Paints and varnishes - Gel permeation chromatography Method (GPC) - Part 1. Tetrahydrofuran as elution agent. " Correspondence between the consistency of the standards of international documents and normative references of the following documents.
--- GB/T 3186-2006 Paints, varnishes and raw materials for paints and varnishes - Sampling (ISO 15528:2000, IDT)
--- GB/T 6379.1-2004 measurement methods and results of Accuracy (trueness and precision) - Part 1. General and given Yi (ISO 5725-1:1994, IDT)
--- GB/T 20777-2006 Paints and varnishes examination and preparation of samples (ISO 1513:1992, IDT) the editorial changes made the following standard.
--- Change the standard name.
The standard proposed by China Petroleum and Chemical Industry Association.
This standard by the National Standardization Technical Committee paint pigment (SAC/TC5) centralized.
This standard was drafted. CNOOC Changzhou coating Chemical Research Institute, Shenzhen Hirota Decoration Group Co., Ltd.
1 Scope
This standard specifies 1) measured was dissolved in THF (tetrahydrofuran) polymer molecular weight distribution by gel permeation chromatography (GPC), the number average molecular weight Mn and the weight average molecular weight Mw approach.
That the use of this method can obtain good reproducibility, this method can not be specific for certain polymer interaction occurs, for example, Adsorption between the sample/eluent/column system occurred.
This method is not an absolute measurement method should be calibrated using commercially available polystyrene standards unbranched material, and this standard Quality has been measured as obtaining absolute molecular weight. Therefore, in addition to polystyrene, the measurement results of the polymer sample is used only between the same type of sample group Comparison.
The conditions specified in this standard does not apply to a value greater than Mw by GPC analysis of polymer sample 106 (see Appendix C).
This standard without correction methods, such as the elimination of peak broadening. If you want to get the absolute molecular weight value, we need to use an absolute measuring method, for example, Determination of Mn Mw measured by a light scattering method or membrane permeation method.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
Check with ISO 1513 Paints and varnishes prepared sample (Paintsandvarnishes-Examinationandpreparation ofsamplesfortesting) ISO 5725-1 measurement methods and results of Accuracy (trueness and precision) - Part 1. General principles and definitions (Accuracy (Truenessandprecision) ofmeasurementmethodsandresults-Part 1. Generalprinciplesanddefini-tions) ISO 15528 Paints, varnishes and raw materials for paints and varnishes - Sampling (Paints, varnishesandrawmaterialsfor paintsandvarnishes-Sampling)
1), also known as Size Exclusion Chromatography (SEC).
3 Terms and Definitions
The following terms and definitions apply to this document.
Gel permeation chromatography Completely dissolved in the eluent molecules is a porous polymer sample and classifying a column filled, depending on the size of the molecule (or, more accurately
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 1513 · ISO 5725 · ISO 15528
How to Download GB/T 27810-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 27810-2011
$315.00