GB/T 27669-2011Non-destructive testing -- Ultrasonic inspection -- Evaluating electronic characteristics of ultrasonic test instruments (English PDF)
无损检测 超声检测 超声检测仪电性能评定
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for GB/T 27669-2011 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 30, 2011
Implementation date
May 1, 2012
Scope
GB/T 27669-2011 is the English-translated version of 无损检测 超声检测 超声检测仪电性能评定.
GB/T 27669-2011 — 1.1 standard established detection method with on-screen display of analog and digital pulse-echo ultrasonic nondestructive testing instrument performance characteristics of the components.
Its purpose is to establish a uniform evaluation method, and compare the measurement results obtained at different times for different laboratories and test data points Analysis process to provide evidence.
This standard does not specify acceptance criteria, the acceptance criteria should be specified by the consumer. Common components and performance characteristics of ultrasonic detector, comprising measuring the performance characteristics of these methods are listed in 1.2 to 1.6.
Found what you need?
Document preview — GB/T 27669-2011
National Standard of the People's Republic of China
- ICS
- 19.100
- Classification
- N 77
Issued by: Standardization Administration of China
Contents
- Introduction
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and symbols
- 4 Abbreviations
- 5 2 Overview
- 6 3 appliance for inspection
- 7 Power detecting section
- 8 Detection pulse generator section
- 9 Detector receiver portion
- 10.00 Detection moiety
- Gate 11 is detected/the alarm section
- 12 18 reporting format
- References
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses the translation method identical with ISO 12710:2002 "NDT ultrasonic testing ultrasonic detector electrical performance assessment" (English Wen first edition).
The standard ISO 12710:2002 made the following editorial changes.
--- Use the "standard" instead of "this International Standard";
--- Deleted international standards foreword, preface rewritten.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
The standard proposed by China Machinery Industry Federation.
This standard by the National Standardization Technical Committee tester (SAC/TC122) centralized.
This standard was drafted. Changchun Research Institute of Machinery Co., Ltd., Guangdong Shantou Ultrasonic Electronics Corp. ultrasound equipment at public Secretary, Edson (Xiamen) Electronics Co., Ltd., Jilin Province Electrotechnical Society, Jilin Vocational and Technical College.
Introduction
Ultrasonic nondestructive testing technique is the use of ultrasonic pulse and echo signals to detect and evaluate the internal structure of the material lattice or uneven distribution defect. Various types of electronic equipment can produce ultrasonic pulse and echo signals.
This standard describes a method for detecting the ultrasonic detector with display performance characteristics. Although these methods can also be detected with higher frequency Rate of ultrasonic detector, but these methods are best suited for detecting the nominal operating frequency range of 100kHz ~ 25MHz ultrasonic detector.
These recommended techniques for the detection of mass-produced industrial ultrasonic detector. When this standard study ultrasound detector can not serve when a combination of electronic components as a whole be described, the ultrasonic detector can be part of each electrical properties were evaluated separately. Evaluation of the ultrasonic inspection each part of the measuring instrument should provide a description of the relevant parts of the assessment.
Implementation of these proposed rules allow more detailed instructions. To use the provisions of electronic instruments is the ability to effectively use these methods Prerequisite. It recommends carefully selecting and determining detection method. If some application-independent parameters and expectations, may not be detected, for example, for example, when using a single-stage alarm defect in the application it is possible and vertical linear independence, only on the basis of ultrasonic flaw detector display accurate detection of deep or the thickness of the horizontal linear only crucial.
Do not make recommendations or give imply shortest cycle assessment ultrasonic detector electrical properties. Measurement accuracy depends not only each parameter Comprehensive accuracy in each electronic equipment (should be given in the technical specifications and calibration of these instruments in the report) but also on the various parts of the system Readings for precision. Can be assumed that the vertical and horizontal reading error measurements measured by the ultrasonic detector for display ± 1mm.
In particular, these techniques and methods in this standard aims to achieve the following purposes.
a) measuring the performance characteristics of the various components of the ultrasonic detector;
b) Check and ensure that the various components of the ultrasonic detector in working life has stability;
c) select and specify the required ultrasonic detector inherent overall performance characteristics;
d) the same type of testing, so that the same parts or the same as the entire instrument interchangeability;
e) For the performance test results of different instruments and test source having a consistency and comparability to create the basic conditions.
NOTE. These methods are not suitable for this standard to exclude some or all of measurement technology ultrasonic testing equipment use or application. In addition, this standard does not it is not suitable for ultrasonic testing system as defined performance specifications. If you need to request performance of the system, it is desirable that the relevant parties agree.
NDT ultrasonic testing Ultrasonic detector electrical performance evaluation
1 Scope
1.1 standard established detection method with on-screen display of analog and digital pulse-echo ultrasonic nondestructive testing instrument performance characteristics of the components.
Its purpose is to establish a uniform evaluation method, and compare the measurement results obtained at different times for different laboratories and test data points Analysis process to provide evidence.
This standard does not specify acceptance criteria, the acceptance criteria should be specified by the consumer.
Common components and performance characteristics of ultrasonic detector, comprising measuring the performance characteristics of these methods are listed in 1.2 to 1.6.
1.2 Power section
--- Linear regulator;
--- Battery discharge time;
--- Battery charging time.
1.3 Pulse generator section
--- Pulse shape;
--- Pulse amplitude;
--- Pulse rise time;
---Pulse Width;
--- Pulse spectrum.
1.4 The receiver section
--- Vertical linear;
---Frequency response;
--- Noise and sensitivity;
--- Gain control.
1.5 Moiety
--- Horizontal linear;
--- Clock (pulse repetition frequency).
1.6 Gate and (or) the alarm section
--- Delay and gate width;
--- Resolution;
--- Alarm level;
--- Gain identity;
--- Analog output;
--- Echo the back gate of the linear.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
IEC 60050-111 International Electrotechnical Vocabulary Chapter 111. Physics and Chemistry (Internationalelectrotechnicalvocabulary
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 60050
How to Download GB/T 27669-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 27669-2011
$325.00