GB/T 26843-2011Carpet -- Determination of resistance to delamination of the backing (English PDF)
地毯 背衬剥离强力的测定
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for GB/T 26843-2011 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Recommended
Issue date
July 29, 2011
Implementation date
December 15, 2011
Scope
GB/T 26843-2011 is the English-translated version of 地毯 背衬剥离强力的测定.
GB/T 26843-2011 — This standard specifies the method of determining the force required to peel off the composite layer of the carpet. This standard applies to all types of carpets with secondary backing or foam backing.
The results of this test method are useful for monitoring the production process, but can not be used as a reliable indicator of performance.
Found what you need?
Document preview — GB/T 26843-2011
National Standard of the People's Republic of China
- ICS
- 59.080.60
- Classification
- W 56
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative reference documents
- 3 Terms and definitions
- 4 Principle
- 5 Equipment
- 6 Samples tested
Foreword
This standard uses the re-drafting method to modify the use of ISO 11857.:1999 "Determination of anti-stripping properties of textile flooring" (English version).
The technical differences between this standard and ISO 11857.:1999 are as follows.
--- GB/T 6529-2008 with the revised international standard instead of ISO 139.
For ease of use, this standard also makes the following editorial changes to ISO 11857.:1999.
--- according to China's carpet series standard naming convention changed the standard name;
--- "this standard" instead of "international standards", with "carpet" instead of "textile floor things";
--- The preamble of the international standard has been removed and the preamble of this standard has been added.
This standard is proposed by the China Light Industry Federation.
This standard is nationalized by the National Carpet Standardization Technical Committee (SAC/TC150).
This standard drafting unit. China Arts and Crafts Association carpet professional committee, Tianjin Oriental sapphire carpet research center.
1 Scope
This standard specifies the method of determining the force required to peel off the composite layer of the carpet.
This standard applies to all types of carpets with secondary backing or foam backing.
The results of this test method are useful for monitoring the production process, but can not be used as a reliable indicator of performance.
2 Normative reference documents
The terms of the following documents are hereby incorporated by reference into this standard. Whichever is the date of the reference file, which is followed by all (Excluding corrigenda) or revisions do not apply to this standard, however, encourage the parties to reach an agreement under this standard Whether you can use the latest version of these files. For undated references, the latest edition applies to this standard.
GB/T 6529-2008 Standard atmosphere for textiles for humidity control and testing (ISO 139.:2005, MOD) ISO 1957 mechanism Carpet physical test sampling and sample interception method (Machine-madetextilefloorcoverings-Se-lectionandcuttingofspecimensforphysicaltests)
3 Terms and definitions
The following terms and definitions apply to this standard.
Stripping force delaminationforce the force required to peel off the carpet's backing layer over a width of 50 mm is expressed in N (Newton).
4 Principle
One end of the test sample was peeled off by hand and then measured under the specified conditions on a continuously recorded tensile strength tester the required force.
5 Equipment
5.1 Tensile testing machine capable of operating at a constant rate of elongation (CRE) of 300 mm/min ± 10 mm/min.
5.2 Clamping system with a dentin-like jaw or padded jaw surface with an area of at least 25 mm x 75 mm, designed to prevent the test is carried out in the fixture sliding.
5.3 Load extension curve Automatic recorder, access or not access to computer backup equipment can be, but should be the same rate of tensile testing machine operating.
5.4 Self-adhesive carpet adhesive tape, 50mm wide.
6 Samples tested
6.1 After sampling according to ISO 1957, five samples of 50mm wide and.200mm long are taken in the production direction and perpendicular to the production direction.
Longer side as test direction. For foam-backed carpets, attach a 50mm wide self-adhesive carpet adhesive tape to the backing (5.4) to prevent the foam from tearing.
6.2 Remove each sample and release the backing layer from one end by about 50 mm by hand.
Note. For a carpet with a mesh or less stable secondary backing, you can use a 50mm long adhesive tape to be laterally attached to the secondary backing to assist the specimen holds the square and clamps it on the specimen holder.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
How to Download GB/T 26843-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 24293-2026 — Thermostatic faucet
GB/T 48132.9-2026 — Green mine construction specifications - Part 9: Cement limestone mine
GB/T 48132.7-2026 — Green mine construction specifications - Part 7: Gold mine
Secure payment via Stripe
Payments accepted
GB/T 26843-2011