Valid

GB/T 26835-2011Non-destructive testing instruments - General specification for industrial X-ray computed tomography(CT)equipment (English PDF)

无损检测仪器 工业用X射线CT装置通用技术条件

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 26835-2011 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 29, 2011

Implementation date

December 1, 2011

Scope

GB/T 26835-2011 is the English-translated version of 无损检测仪器 工业用X射线CT装置通用技术条件.

GB/T 26835-2011 is the Chinese standard "Non-destructive testing instruments - General specification for industrial X-ray computed tomography(CT)equipment".

Its scope clause reads: This standard specifies the terms and definitions of industrial X-ray CT apparatus (hereinafter referred to as CT apparatus), the basic structure, requirements, performance parameters The number of test methods, inspection rules, marking, packaging, transportation and storage.

This standard applies to the use of low-energy X-ray tube X-ray source and the use of high-energy electron linear accelerator X-ray source is fixed and Portable industrial X-ray CT apparatus. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 26835-2011

National Standard of the People's Republic of China

ICS
19.100
Classification
N 78

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 5 Requirement
  • 5.1 Specimen range
  • 5.2 Detection Time
  • 5.4 reconstruction matrix
  • 5.5 defect detection capability
  • 6 Performance Parameter
  • 6.1 Focus
  • 6.2 ray dose rate
  • 6.3 Spatial resolution
  • 6.4 density resolution
  • 6.5 cursor positioning accuracy
  • 7 Test Method
  • 7.2 density resolution test
  • 7.3 Position the cursor measurement accuracy
  • 8 5 Inspection Rules
  • 8.1 product testing factory
  • 8.2 Type inspection
  • 9 signs, packaging, transportation and storage
  • 9.1 6 logo
  • 9.2 Packaging
  • 9.3 Transportation and storage
  • Appendix A (normative) Method Round Passes test card test spatial resolution
  • Annex B (informative) algorithm flow test disc method
  • References

1 Scope

This standard specifies the terms and definitions of industrial X-ray CT apparatus (hereinafter referred to as CT apparatus), the basic structure, requirements, performance parameters

The number of test methods, inspection rules, marking, packaging, transportation and storage.

This standard applies to the use of low-energy X-ray tube X-ray source and the use of high-energy electron linear accelerator X-ray source is fixed and

Portable industrial X-ray CT apparatus.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 191 Packaging - Pictorial signs (GB/T 191-2008, ISO 780.1997, MOD)

GB/T 12604.2-2005 Terminology for nondestructive testing radiographic testing (ISO 5576.1997, IDT)

GB/T 13384 mechanical and electrical products packaging General technical conditions

GB 18871 ionizing radiation protection and safety of radiation sources basic standards

JB/T 9329 Instrumentation transport, transportation, storage and basic environmental conditions and test methods

3 Terms and Definitions

GB/T 12604.2-2005 and as defined in the following terms and definitions apply to this document.

3.1 Emitter radiationsource

Means (e.g., gamma ray source or the X-ray tube) capable of emitting ionizing radiation.

3.2 Detector

Is information about the sensor test object is used for processing shifts around the test object into the electronic sensing device containing radioactive electrical information

Sub-signals.

3.3 Electrical radiation generators

Generating spot size of a few millimeters to a few microns in the X-ray appliances.

3.4 X-ray CT apparatus X-rayComputedTomography (CT) equipment

X-ray emission as an energy source, the use of industrial computer tomography testing apparatus.

3.5 Control area

In one area of radiation in the workplace division within this area require or may require to take special protective measures and safety measures,

In order to. a) under normal operating conditions to control or prevent the spread of contamination normal irradiation; b) to prevent or limit its potential exposure program.

GB 22448-2025 | GB/T 36017-2018 | GB/T 36015-2018 | GB/T 26838-2024 | GB/T 26832-2011 | GB/T 26830-2011 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 26835-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 26835-2011

$255.00