GB/T 26834-2011Non-destructive testing instruments -- Measurement of effective focal spot size of mini and micro focus X-ray tubes (English PDF)
无损检测仪器 小焦点及微焦点X射线管有效焦点尺寸测量方法
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for GB/T 26834-2011 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
July 29, 2011
Implementation date
December 1, 2011
Scope
GB/T 26834-2011 is the English-translated version of 无损检测仪器 小焦点及微焦点X射线管有效焦点尺寸测量方法.
GB/T 26834-2011 — The standard provides a clear edge X-ray tube voltage 225kV X-ray is not greater than the effective focal spot size of 5µm ~ 300µm Radiographic measurements.
X-ray image quality and resolution of the image depends on the characteristics of focus, focus, image quality relies on two-dimensional plane of the object density distributed.
X-ray radiographic techniques used for specific purposes. Note. By using the same method can be negotiated to a higher voltage kV X-ray tube, but measurement accuracy is poor.
Found what you need?
Document preview — GB/T 26834-2011
National Standard of the People's Republic of China
- ICS
- 19.100
- Classification
- N 78
Issued by: Standardization Administration of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Test Method
- 4.1 Principle and equipment
- 4.2 Distance and exposure time selection
- Determination of measurement and focus size 5
- 5.1 Measurement
- 5.2 Determination of
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard corresponds to British Standard BSEN12543-5:1999 "focus behavior of industrial X-ray apparatus for non-destructive testing of the first Part 5. Small focus and micro focus X-ray tube effective focal spot size measurement method ", with its main technical differences are as follows.
--- Increased Chapter 3 Terms and definitions;
--- Increased in Chapter 2, normative references; direct reference to the latest version of the European standard corresponding to our standards.
For ease of use, this standard made the following editorial changes.
--- Use the "standard" instead of the "European standard";
--- Remove European standard BSEN12543-5:1999 Foreword;
--- Remove European standard BSEN12543-5:1999 Introduction;
--- With Chinese decimal comma instead of the original English.
The standard proposed by China Machinery Industry Federation.
This standard by the National Standardization Technical Committee tester (SAC/TC122) centralized.
1 Scope
The standard provides a clear edge X-ray tube voltage 225kV X-ray is not greater than the effective focal spot size of 5µm ~ 300µm Radiographic measurements.
X-ray image quality and resolution of the image depends on the characteristics of focus, focus, image quality relies on two-dimensional plane of the object density distributed.
X-ray radiographic techniques used for specific purposes.
Note. By using the same method can be negotiated to a higher voltage kV X-ray tube, but measurement accuracy is poor.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 12604.2-2005 Terminology for nondestructive testing radiographic testing (ISO 5576:1997, IDT) GB/T 19348.1-2003 destructive testing - Industrial radiographic film - Part 1. Classification of film systems for industrial radiography (ISO 11699-1:1998, IDT)
3 Terms and Definitions
Terms and definitions GB/T 12604.2 established in this document apply.
Test Method 4
4.1 Principle and equipment
This method is an indirect measure of geometric clarity by measuring the focal spot size. For this reason a clear edge imaging either in film or ray the image forming apparatus have adopted a high geometric magnification.
If using film measurement requires the following equipment.
--- Test substance;
--- Film, the minimum 10cm × 10cm, without sensitization;
--- Low absorbent material film cartridge (example. polyethylene);
--- Film clip;
--- Film processing unit;
--- Can be read density greater than 3.0 micrometer densitometer, and there d1<=10µm input diaphragm.
If ray imaging device measurements require the following equipment.
--- Test substance;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 12604.2-2005 · ISO 5576 · ISO 11699
How to Download GB/T 26834-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 24293-2026 — Thermostatic faucet
GB/T 48132.9-2026 — Green mine construction specifications - Part 9: Cement limestone mine
GB/T 48132.7-2026 — Green mine construction specifications - Part 7: Gold mine
Secure payment via Stripe
Payments accepted
GB/T 26834-2011
$75.00