GB/T 26688-2023Automatic test systems for battery powered emergency escape lighting (English PDF)
电池供电的应急疏散照明自动试验系统
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/T 26688-2023 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
December 28, 2023
Implementation date
July 1, 2024
Scope
GB/T 26688-2023 is the English-translated version of 电池供电的应急疏散照明自动试验系统.
GB/T 26688-2023 — This document specifies the automatic testing of independent products and combinations used with emergency lighting systems with a power supply voltage not exceeding 1000V: Basic performance and safety requirements for components within the system: This document also specifies the functional requirements for a complete automatic test system for emergency lighting systems: This document applies to test systems containing self-contained emergency lighting fixtures or a central battery associated with an emergency lighting fixture: NOTE: Manual test equipment that relies on manual initialization and/or visual inspection of lamp status is outside the scope of this document:
Found what you need?
Document preview — GB/T 26688-2023
National Standard of the People's Republic of China
- ICS
- 29.140.50
- Classification
- K 70
- Replacing
- GB/T 26688-2011
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Request
- 5 Test duration and intervals
- 6 Protection of buildings during testing and subsequent recharging of emergency lighting systems
- 7 Labeling and recording of test results of testing equipment
- Appendix A (informative) Examples of typical automatic test systems
- Appendix B (Normative) Classification of ATS
- Appendix C (informative) ATS User Guide
- Reference
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents" Drafting:
This document replaces GB/T 26688-2011 "Battery-powered emergency evacuation lighting automatic test system" and is consistent with GB/T 26688-2011 in comparison, in addition to structural adjustments and editorial changes, the main technical changes are as follows:
a) Changed the requirements for monitoring of timing circuits (see 4.2, 4:2 of the:2011 edition);
b) Changed the requirements for automatic test systems (ATS) (see 4.3:1, 4:3:1 of the:2011 version);
c) Changed the requirements for internal communication failure (see 4.4:2, 4:4:2 of the:2011 version);
d) Changed the requirements for component failure (see 4.4:4, 4:4:4 of the:2011 edition);
e) Changed the requirements for software failure (see 4.4:7, 4:4:7 of the:2011 version);
f) The requirements for functional testing have been changed (see 5.1, 5:1 of the:2011 version);
g) The requirements for continuous testing have been changed (see 5.2, 5:2 of the:2011 version);
h) Changed the requirements for timer accuracy (see 6.2:2, 6:2:2 of the:2011 version);
i) Changed the requirements for interactive lamp testing (see 6.3:2:2, 6:3:2:2 of the:2011 edition);
j) The requirements for limited continuous testing have been changed (see 6.3:3:4, 6:3:3:4 of the:2011 edition);
k) Changed general requirements (see 7.1,:2011 version of 7:1):
This document is modified to adopt IEC 62034:2012 "Battery-powered automatic test system for emergency evacuation lighting":
The technical differences between this document and IEC 62034:2012 and their reasons are as follows:
---Replaced IEC 60598-1 with normative reference GB/T 7000.1, and GB/T 7000.222 replaced IEC 60598-2-22, to facilitate the application of series standards:
Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents:
Introduction
The emergency lighting system is a safety-related product, and the correctness of its performance needs to be guaranteed through system testing and maintenance: traditional detection techniques the technique relies on manual detection procedures and is susceptible to oversight: Automated detection procedures can overcome the limitations of traditional technologies: important Yes, the automatic test system for emergency lighting can reliably arrange testing and provide real-time reminders of performance failure and performance degradation:
When a fault is discovered, the automatic test system (ATS) will still require manual intervention to correct the fault and set procedures for such intervention: This series the system provides information and supports users in risk management at the place of use:
ATS for emergency evacuation lighting displays test results at predetermined intervals without cutting off any other electrical equipment to help Building managers: In order to restore the emergency evacuation system to full operation, provide early notification of performance failures and degradations that occur is very important: ATS provides information for emergency lighting facilities to ensure that the installed luminaires can function properly when needed:
ATS is part of the building management system (BMS) for emergency lighting inspection; this document only applies to emergency lighting in the BMS:
Ming detection part:
Visual inspection of system components and indicators is a routine part of the safety officer's job: This inspection needs to be carried out on a daily basis to ensure that the emergency lighting fixtures Ready to use and complete, with lights and indicators functioning properly and clearly visible, i.e. not obscured, or altered:
Battery-powered emergency evacuation lighting automatic test system
1 Scope
This document specifies the automatic testing of independent products and combinations used with emergency lighting systems with a power supply voltage not exceeding 1000V:
Basic performance and safety requirements for components within the system:
This document also specifies the functional requirements for a complete automatic test system for emergency lighting systems:
This document applies to test systems containing self-contained emergency lighting fixtures or a central battery associated with an emergency lighting fixture:
NOTE: Manual test equipment that relies on manual initialization and/or visual inspection of lamp status is outside the scope of this document:
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations for undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document:
GB/T 7000.1 Luminaires Part 1: General requirements and tests (GB/T 7000.1-2023, IEC 60598-1:2020, MOD) GB/T 7000.222 Luminaires Part 2-22: Emergency lighting fixtures with special requirements (GB/T 7000.222-2023, IEC 60598-2-22:2021, MOD) IEC 60073 Basic and safety rules for the marking of human-machine interface signs Coding rules for indicators and operating devices (Basicand torsandactuators) Note: GB/T 4025-2010 Basic and safety rules for human-machine interface sign identification Coding rules for indicators and operating devices (IEC 60073:
2002,IDT)
IEC 61347-1 Lamp control gear Part 1: General and safety requirements (Lampcontrolgear-Part 1:
Note: GB/T 19510.1-2023 Light source control device Part 1: General requirements and safety requirements (IEC 61347-1:2017, MOD) Note: GB/T 18595-2014 Electromagnetic compatibility and immunity requirements for general lighting equipment (IEC 61547:2009, IDT)
3 Terms and definitions
The terms and definitions defined in IEC 7000.222 and the following apply to this document:
Automatic test system automatictestsystem;ATS an automatic test system that can be initialized manually: When connected together to form a system, it can perform routine testing requirements and standardize emergency lighting fixtures:
It consists of components that display test results (such as timers, current probes, light probes, and transfer switches):
An emergency lighting fixture with a built-in test device for conducting tests and marking the test results:
Note: Examples of self-contained luminaires are given in Appendix A:
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
How to Download GB/T 26688-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 26688-2023