GB/T 26594-2011Non-destructive testing instruments - Properties test methods of industrial X-ray tube (English PDF)

无损检测仪器 工业用X射线管性能测试方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for GB/T 26594-2011 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 16, 2011

Implementation date

November 1, 2011

Scope

GB/T 26594-2011 is the English-translated version of 无损检测仪器 工业用X射线管性能测试方法.

GB/T 26594-2011 is the Chinese standard "Non-destructive testing instruments - Properties test methods of industrial X-ray tube".

Its scope clause reads: This standard specifies the requirements and test conditions for the technical parameters of industrial X-ray tube (hereinafter referred to as the X-ray tube) of the test strip Parts and test methods.

This standard applies to all types of industrial X-ray tube (not including pulsed). Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 26594-2011

National Standard of the People's Republic of China

ICS
19.100
Classification
N 78

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Test Conditions
  • 4.1 Test Equipment
  • 4.2 Test Schematic
  • 4.3 Test Rule
  • 5.1 filament characteristics Test
  • 5.2 X-ray tube maximum working tube voltage test
  • 5.3 X-ray tube maximum peak reverse voltage test
  • 5.4 X-ray tube overvoltage test
  • 5.7 X-ray tube 5 Maximum Power Test
  • 5.8 X-ray tube effective focal spot size of the test
  • 5.9 X-ray tube radiant energy flux density uniformity test
  • 5.11 X-ray tube inherent filtration test
  • 5.12 X-ray tube spectral purity test
  • 5.13 Test gated X-ray tube anode current cutoff characteristics
  • 5.14 gated X-ray tube filament inter-gate voltage test
  • Appendix A (normative) Pinhole radiography
  • Appendix B (normative) Focus slit radiography
  • Annex C (informative) electrical schematic diagram

1 Scope

This standard specifies the requirements and test conditions for the technical parameters of industrial X-ray tube (hereinafter referred to as the X-ray tube) of the test strip

Parts and test methods.

This standard applies to all types of industrial X-ray tube (not including pulsed).

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent

Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research

Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 2421-1999 electric and electronic products environmental testing rules - Part 1. General

GB/T 25758.5-2010 destructive testing of industrial X-ray system focus characteristics - Part 5. Focus small and micro-focus X-ray

Measurement of the effective focal spot size of the pipe line

3 Terms and Definitions

The following terms and definitions apply to this standard.

3.1 Filament characteristics

Relationship between X-ray tube filament current and filament voltage.

3.2 Maximum operating tube voltage

Since the half-wave rectifier circuit, X-ray tube anode rated current between the anode and cathode of the maximum allowed forward anode voltage

Peak.

3.3 Maximum peak reverse voltage

X-ray tube anode current provisions, the maximum allowed withstand peak reverse voltage between the anode and the cathode.

3.4 Overvoltage

In the anode current and test time prescribed between the X-ray tube anode and cathode by adding a predetermined overvoltage coefficient determined

Peak voltage.

3.5 Filament emission characteristics

Under the given conditions of tube voltage, anode current and filament current (voltage) relationship between the X-ray tube.

3.6 Anode current stability

X-ray tube under specified operating conditions and within the stipulated time, the amount of the maximum anode current variation of the rated current value of the ratio of the anode.

GB 22448-2025 | GB/T 36017-2018 | GB/T 36015-2018 | GB/T 26595-2011 | GB/T 26593-2011 | GB/T 26592-2011 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 26594-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 26594-2011

$375.00