GB/T 26305-2010The method for chemical of nickel oxide -- Determination of nickel content -- Electrolytic deposition method (English PDF)
氧化镍化学分析方法 镍量的测定 电沉积法
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for GB/T 26305-2010 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
January 14, 2011
Implementation date
November 1, 2011
Scope
GB/T 26305-2010 is the English-translated version of 氧化镍化学分析方法 镍量的测定 电沉积法.
GB/T 26305-2010 — This standard specifies the method for determination of electrodeposited nickel oxide and nickel oxide partial reduction in nickel content. This standard applies to nickel oxide and nickel oxide partial reduction in the amount of nickel electrodeposition measurement method, measurement range. 70% to 95% (by mass fraction).
Found what you need?
Document preview — GB/T 26305-2010
National Standard of the People's Republic of China
- ICS
- 77.120.40
- Classification
- H 13
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 PRINCIPLE OF THE METHOD
- 4 Reagents
- 5 Instruments
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This revised standard adopts ISO 12169:1996 "Determination of nickel content of nickel oxide electrolytic deposition method." And ISO 12169:1996 Phase Than the standard main changes are as follows.
--- Reference standard adopts the international standard ISO 3696 corresponding to GB/T 6682 "Test Methods for laboratory use - Specification and Analysis";
--- Reagent ethanol instead of methanol;
--- In 4.8,4.9, and with "excellent level of pure" reagent instead of "reagent grade" reagents;
--- 5.1 in the "semi-micro analytical balance, a sense of the amount of 0.01mg", according to the actual operational requirements to "analytical balance, a sense of volume 0.1mg ";
--- 5.3 in "a spiral coil-shaped anode" to "anode is a helical coil or mesh";
--- In 7.1.1, the sample weight "accurate to 0.001g" to "accurate to 0.1mg", with a "beaker" instead of "Pyrex Beaker ";
--- 7.1.4 with the "speed quantitative filter paper" instead of "40 this standard and ISO 12169:1996 correspondence between the provisions of Appendix D.
This standard by the national non-ferrous metals Standardization Technical Committee (SAC/TC243) centralized.
1 Scope
This standard specifies the method for determination of electrodeposited nickel oxide and nickel oxide partial reduction in nickel content.
This standard applies to nickel oxide and nickel oxide partial reduction in the amount of nickel electrodeposition measurement method, measurement range. 70% to 95% (by mass fraction).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6682 analytical laboratory use specifications and test methods (ISO 3696. 1987, MOD)
3 PRINCIPLE OF THE METHOD
Sample was dissolved in a solution of nitric acid and potassium chlorate, sulfuric acid nitric acid to remove smoke, coke residue dissolved potassium melt decomposition. In Ammonia the electrolytic deposition of nickel, weighing sediment quality. Quality measurement of residual ammonia electrolyte of nickel by atomic absorption spectrometry coupled with mass deposition of nickel it is the actual mass of nickel. Fixed deposits with moisture measurement sample nickel net mass.
4 Reagents
Unless otherwise specified, the reagents were of analytical grade, water GB/T 6682 as specified in Class 2 water.
4.1 hydrochloride, rho20 = 1.18g/mL, diluted to (11).
4.2 sulfate, rho20 = 1.84g/mL, diluted to (11).
Nitric acid 4.3, rho = 1.41g/mL, diluted to (11).
4.4 hydrofluoric acid, rho20 = 1.13g/mL, diluted to (11).
Warning. hydrofluoric acid on the skin and mucous membranes have a strong irritant, corrosive, can cause severe burns and difficult to cure. Once the skin Contact with hydrofluoric acid, washed thoroughly cleaned after medical treatment.
4.5 ammonia, rho20 = 0.89g/mL.
4.6 potassium chlorate (KClO3), pure class distinctions.
Warning. potassium chlorate is a strong oxidant, after mixing with certain substances, an explosion will occur.
4.7 potassium pyrosulfate (K2S2O7), pure class distinctions.
4.8 dimethylglyoxime solution. 1g Diacetyldioxime dissolved in 100mL of ethanol.
5 Instruments
5.1 Analytical balance, a sense of the amount of 0.1mg.
5.2 electrolytic deposition apparatus (see FIG. 1).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 3696
How to Download GB/T 26305-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
Secure payment via Stripe
Payments accepted
GB/T 26305-2010
$225.00