Scope

GB/T 26284-2010 is the English-translated version of 变形镁合金熔剂、氧化夹杂试验方法.

GB/T 26284-2010 is the Chinese standard "Experimental method for flux inclusions and oxide in wrought magnesium alloys". Its scope clause reads: This standard specifies the wrought magnesium alloy ingots and processed products in flux, the test method oxidized inclusions.

This standard applies to flux and oxidation wrought magnesium alloy ingots and processed products inclusions detected. Its clauses include reagents and equipment; sampling; test procedure.

Found what you need?

Document preview — GB/T 26284-2010

National Standard of the People's Republic of China

ICS
77.040.01
Classification
H 12

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Reagents and equipment
  • 4 sampling
  • 5 test procedure

1 Scope

This standard specifies the wrought magnesium alloy ingots and processed products in flux, the test method oxidized inclusions.

This standard applies to flux and oxidation wrought magnesium alloy ingots and processed products inclusions detected.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent

Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research

Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 6682 analytical laboratory use specifications and test methods

3 Reagents and equipment

3.1 Reagents

3.1.1

nitric acid (14).

3.1.2

silver nitrate solution (0.1mol/L).

3.1.3 Water

in line with GB/T 6682 in three.

3.2 Equipment

3.2.1 temperature and humidity chamber

temperature range of 0 °C ~ 100 °C, humidity range of 30% ~ 98% RH, can automatically control

System temperature and humidity, the effective volume of the test may be determined according to the size and number of parts to be detected.

3.2.2 Magnifier

with scale, zoom more than 10 times multiple.

4 sampling

Wrought magnesium alloy ingots and product tests are carried out on the test piece. Unless otherwise specified, at the beginning of ingot, middle and end parts of the cut

Take appropriate cross-sectional area and the size of the specimen tested; if not intercepted in the middle of the test piece, allowing only the start and end parts of the intercept test

Sheets for testing.

5 test procedure

5.1 Test surface cleaning before the test piece

Before the test strip into the climatic chamber must ensure that the test strip has a new section and clean surface. You can use the magnesium alloy corrosion-free removal

Oil, alcohol or clean cloth and so remove the test piece surface grease, fingerprints, magnesium shavings and dust. After machining the test piece surface roughness Ra should be small

At 3.2µm. After the completion of the preparation of the specimen from the start of the trial into a constant temperature and humidity box storage time should not exceed 24h, and should be kept in a dry

Atmosphere.

5.2 Test

5.2.1

test at a temperature of 32 °C ± 2 °C, relative humidity of 90% ± 2% of the constant temperature and humidity chamber continued 8h, test time can also be based

Customer requirements for consultation, but not less than 4h; sample holder should be placed parallel to each other and the surface to be detected spaced, vertical or horizontal plane to maintain

An angle (to 60 ° ~ 70 ° is appropriate) to avoid detection surface to form water marks.

5.2.2

After the test, the test piece was taken out from the constant temperature and humidity chamber, or visually using a magnification of 10 times magnifying glass specimen table

Surface for corrosion product. Statistics are the size and number of corrosion spots. For further confirmation of the corrosion products, executable 5.2.3 step.

GB/T 20975.28-2019 | GB/T 20975.29-2019 | GB/T 20975.30-2019 | GB/T 13748.15-2026 | GB/T 13748.13-2026 | GB/T 13748.1-2026 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 26284-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 26284-2010

$85.00