GB/T 25890.8-2010Railway applications -- Fixed installations -- DC switchgear -- Part 7-2: Measurement, control and protection devices for specific use in d.c. traction systems -- Isolating current transducers and other current measuring devices (English PDF)
轨道交通 地面装置 直流开关设备 第7-2部分:直流牵引供电系统专用测量、控制和保护装置 隔离电流变送器和其他电流测量设备
This is a limited preview
Buy now to download the full PDF (5 pages)
Need quotation for your management?
Get a formal quotation for GB/T 25890.8-2010 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
January 10, 2011
Implementation date
June 1, 2011
Scope
GB/T 25890.8-2010 is the English-translated version of 轨道交通 地面装置 直流开关设备 第7-2部分:直流牵引供电系统专用测量、控制和保护装置 隔离电流变送器和其他电流测量设备.
GB/T 25890.8-2010 — This section GB/T 25890 specifies the current transmitter isolation and other current measuring facilities and for rail transport dc ground means Desired amount of equipment.
The transmitter is usually installed between the primary-side switchboard equipment sensors or rail and the secondary side equipment to provide electrical input and output insulation.
Found what you need?
Document preview — GB/T 25890.8-2010
National Standard of the People's Republic of China
- ICS
- 29.280
- Classification
- S 35
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Operating Conditions
- 5 Features
- 5.1 Electrical Characteristics
Foreword
GB/T 25890 "Light Rail DC switchgear apparatus" consists of the following components.
--- Part 1. General;
--- Part 2. DC circuit breaker;
--- Part 3. Indoor dc isolation switch, load switch and earthing switch;
--- Part 4. Outdoor DC isolation switch, load switch and earthing switch;
--- Part 5. DC surge arresters and low voltage limiters;
--- Part 6. DC switchgear equipment;
--- Part 7-1. DC traction power supply system-specific measurement, control and protection devices Application Guide;
--- Part 7-2. DC traction power supply system-specific measurement, control and protection devices for isolating current transducers and other current measuring equipment;
--- Part 7-3. DC traction power supply system-specific measurement, control and protection devices and other isolated voltage transducer voltage measurement equipment.
This is Part 7-2 GB/T 25890 of.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with IEC 61992-7-2:2006 "Light Rail DC switchgear apparatus 7-2 Part I. DC traction power supply system-specific measurement, control and protection devices for isolating current transducers and other current measuring devices "(in English).
Correspondence with consistency in this section of our normative references the following documents.
--- GB/T 24338.1-2009 rail Electromagnetic compatibility - Part 1. General (IEC 62236-1:2003, IDT);
--- GB/T 24338.3-2009 rail Electromagnetic compatibility Part 3-1. Rolling stock train and vehicle (IEC 62236-3-1:2003, IDT);
--- GB/T 24338.4-2009 rail Electromagnetic compatibility Part 3-2. Rolling stock equipment (IEC 62236-3-2.
2003, MOD);
--- GB/T 24338.5-2009 rail Electromagnetic compatibility - Part 4. Emission and immunity of the signaling and telecommunications apparatus (IEC 62236-4:2003, IDT);
--- GB/T 24338.6-2009 rail Electromagnetic compatibility - Part 5. Anti-emission and ground power units and equipment scrambling Degree (IEC 62236-5:2003, IDT).
This section proposed by the People's Republic of China Ministry of Railways.
This part of the National electric traction equipment and systems Standardization Technical Committee (SAC/TC278) centralized.
This section is responsible for drafting unit. China Railway Electrification Survey Design and Research Institute Limited.
Participated in the drafting of this section. The Siyuan Group Co., Ltd., Tianjin Hyflux Electric Company.
1 Scope
This section GB/T 25890 specifies the current transmitter isolation and other current measuring facilities and for rail transport dc ground means Desired amount of equipment.
The transmitter is usually installed between the primary-side switchboard equipment sensors or rail and the secondary side equipment to provide electrical input and output insulation.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 25890.1-2010 Light Rail system DC switchgear - Part 1. General (IEC 61992-1.
2006, IDT)
IEC 62236 (all parts), Railway applications - Electromagnetic compatibility (Railwayapplication-Electromagneticcompati-bility) EN50124-1:2001 Railway applications - Insulation coordination - Part 1. General requirements and creep voids all electrical and electronic equipment Variable distance (Railwayapplication-Insulationcoordination-Part 1. Basicrequirements-Clearancesand creepagedistancesforelectricalandelectronicequipment)
3 Terms and Definitions
Terms and definitions GB/T 25890.1-2010 established applicable to this document.
4 Operating Conditions
When the device is mounted on the apparatus and equipment GB/T 25890 stipulated, consistent with their working conditions and equipment and complete sets of equipment.
In this section, EN50124-1. Pollution Level PD4 and overvoltage category described in 2001 (see GB/T 25890.1-2010 Notes to Table 1) is considered normal working conditions.
Normal operating conditions, see GB/T 25890.1-2010 Appendix B.
5 Features
5.1 Electrical Characteristics
5.1.1 Overview
Isolation transmitter once the same insulation level insulation class and the main circuit side and the secondary side connection terminals.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 61992 · IEC 62236
How to Download GB/T 25890.8-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 25890.1-2026 — Railway applications - Fixed installations - DC switchgear - Part 1: General
GB/T 25890.2-2026 — Railway applications - Fixed installations - DC switchgear - Part 2: DC circuit breakers
GB/T 25890.3-2026 — Railway applications - Fixed installations - DC switchgear - Part 3: Indoor d. c. disconnectors, switch-disconnectors and earthing switches
Secure payment via Stripe
Payments accepted
GB/T 25890.8-2010
$85.00