Scope
GB/T 25890.3-2026 is the English-translated version of 轨道交通 地面装置 直流开关设备 第3部分:户内直流隔离开关、负荷开关和接地开关.
GB/T 25890.3-2026 — This document specifies the operating conditions, switch... Characteristics, structural and performance requirements, information and labeling, inspection rules, and related test methods are described.
This document applies to the selection and inspection of indoor DC disconnect switches, load switches, and grounding switches in the ground installation of traction power supply systems.
This document does not apply to the requirements for switchgear assemblies, electromagnetic compatibility (EMC), and reliability, which are defined in GB/T 25890.
His part stipulates. Note 1.In this document, "switch" refers to "DC disconnect switch and/or load switch" as defined in 3.1.5, 3.1.6 and 3.1.7 of GB/T 25890.1-2026. and/or grounding switch.
Found what you need?
Document preview — GB/T 25890.3-2026
National Standard of the People's Republic of China
- ICS
- 29.280
- Classification
- S 81
- Replacing
- GB/T 25890.3-2010
Issued by: State Administration for Market Regulation
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative References
- 3 Terms and Definitions
- 4 Working conditions
- 5 Switching Characteristics
- 5.1 Feature Overview
- 5.2 Switch Type
- 5.3 Rated value
- 5.4 Use Category
- 5.5 Control Circuit
- 5.6 Auxiliary Contacts and Auxiliary Circuits
- 6 Structural and Performance Requirements
- 6.1 General Requirements
- 6.2 Materials
- 6.3 Arc Contact
- 6.4 Clearances and Creepage Distances
- 6.5 Main Circuit Connection
- 6.6 Main circuit connection location
- 6.7 Grounding terminal
- 6.8 Manual Operation Method
- 6.9 Switch housing
- 6.10 Temperature rise
- 6.11 Insulation strength
- 6.12 Electrical and mechanical durability
- 6.13 Operation
- 6.14 Corrosion Protection
- 6.15 Noise
- 6.16 Cooling
- 6.17 Servo Control (if applicable)
- 6.18 Other devices
- 7 Information and Identification
- 7.1 Information
- 7.2 Identification
- 8 Test Methods 7.
- 8.1 General Requirements
- 8.2 Test Methods
- 9 Inspection Rule
- 9.1 General Requirements
- 9.2 Inspection Item
- Appendix A (Informative) Required Information
- A.1 Overview
- A.2 Procurement Technical Requirements
- A.3 Production Technology Requirements
- Reference
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents".
Drafting.
This document is Part 3 of GB/T 25890 "DC Switchgear for Ground Installations in Rail Transit". GB/T 25890 has been issued.
The following parts were laid out.
---Part 1: General Provisions;
---Part 2: DC Circuit Breakers;
---Part 3: Indoor DC disconnect switches, load switches and grounding switches;
---Part 4: Outdoor DC disconnect switches, load switches and grounding switches;
---Part 5: DC Switchgear Assemblies;
---Part 7-1.Application Guidelines for Dedicated Measurement, Control, and Protection Devices for DC Traction Power Supply Systems;
---Part 7-2.Dedicated Measurement, Control, and Protection Devices for DC Traction Power Supply Systems. Isolated Current Transmitters and Other Current Measurements equipment;
---Part 7-3.Dedicated Measurement, Control, and Protection Devices for DC Traction Power Supply Systems. Isolated Voltage Transmitters and Other Voltage Measurement Devices equipment.
This document replaces GB/T 25890.3-2010 "DC Switchgear for Ground Installations in Rail Transit - Part 3: Indoor DC Isolation Equipment".
"Off-grid switches, load switches and grounding switches", compared with GB/T 25890.3-2010, except for structural adjustments and editorial changes, the main technical differences are as follows.
The changes are as follows.
a) The scope has been changed (see Chapter 1, Chapter 1 of the 2010 edition);
b) The voltage specifications for rated short-circuit breaking and making capabilities have been changed (see 5.3.3, 2010 edition of 5.3.3);
c) The time constant determination principle for the closing/breaking load capacity of switch types and the fault current operating frequency of Class V switches have been changed.
Definitions (see Table 1, 2010 edition);
d) The requirement that switches conform to the production drawings has been added (see 6.1);
e) The requirements for both buyers and sellers have been removed (see 6.14 in the 2010 edition);
f) The requirement for mutual agreement to adjust tolerances has been removed (see 8.3.7.2 in the 2010 version);
g) The type of switch and the time constants for closing and breaking capacity tests have been changed in the closing capability test (see 8.2.7.4, 2010 version).
8.3.7.4);
h) General requirements for inspection rules have been added (see 9.1);
i) The inspection items have been changed (see Table 2, Table 2 in the 2010 edition).
This document is modified to adopt IEC 61992-3:2015 "DC switchgear for ground installations on rail transit - Part 3: Indoor DC isolation".
"Leave the switch, load switch and grounding switch".
Compared with IEC 61992-3:2015, this document has undergone the following structural adjustments.
---8.2 corresponds to 8.3 of IEC 61992-3:2015;
---Chapter 9 and 9.1 "General Requirements" have been added;
---9.2 corresponds to 8.2 of IEC 61992-3:2015.
The technical differences between this document and IEC 61992-3:2015, and the reasons therefor, are as follows.
---The scope has been revised (see Chapter 1), and applicability requirements have been added to adapt to my country's national conditions;
---EN50124-1:2001 (see 5.5, 5.6) has been replaced by the normatively referenced GB/T 32350.1, and GB/T 11022-2020 has been replaced by...
The new standard replaces IEC 60694 (see 8.2.1.2), and GB/T 25890.1-2026 replaces IEC 61992-1:2006 (see Chapter 3).
Chapters 4, 5.2-5.6, 6.1, 6.2, 6.4, 6.10, 6.11, 7.2, 8.1, 8.2, and 9.2), GB/T 25890.5-2026 replaces [the previous standard].
IEC 61992-6:2006 (see 5.4, 6.6, 6.7, 6.9) was adopted to adapt to my country's technical conditions and increase operability.
---Added information on whether the product meets the requirements of the production drawings (see 6.1), clarifying the requirements;
---The notes in sections 6.2 and 6.4 have been changed to main text to clarify requirements and facilitate use;
---Content that could be agreed upon by the manufacturer and user has been removed (see IEC 61992-3:2015, 6.12, 6.18, 8.3.5, 8.3.6).
8.3.7.2 and 8.3.7.4) clearly define the requirements and facilitate use;
---Type testing requirements have been added (see Chapter 9) to adapt to my country's national conditions;
---The section "Test Items and Test Order" has been changed to "Inspection Items" (see 9.2) to better suit my country's national conditions;
---Added clauses on inspection classification and technical requirements (see Table 2) to adapt to my country's national conditions.
The following editorial changes have been made to this document.
---In section 5.3.2, GB/T 1402-2025, a reference standard, has replaced IEC 60850:2000 to better suit my country's national conditions;
---The test requirements and methods for electrical and mechanical durability in IEC 61992-3:2015 6.12 are incorporated into sections 8.2.5 and 8.2.6 to adapt to...
my country's national conditions;
---Note in IEC 61992-3.20158.2.1.2 has been amended.
Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.
This document was proposed by the National Railway Administration.
This document is under the jurisdiction of the National Technical Committee on Standardization of Rail Transit Electrical Equipment and Systems (SAC/TC278).
Introduction
In the rail transit sector, DC switchgear is a crucial power transmission and distribution device in traction power supply systems, and its performance significantly impacts the traction power supply system.
The safe and reliable operation of these devices is of paramount importance. GB/T 25890, "DC Switchgear for Ground Installations in Rail Transit," aims to define...
This document serves as a basis for the design, manufacture, and inspection of DC switchgear and control equipment used in ground installations of rail transit traction power supply systems. It is proposed to be drafted by eight [unclear - likely referring to organizations or entities].
It consists of several parts.
---Part 1: General Provisions. The purpose is to specify the operating conditions of DC switching and control equipment in the ground installation of the traction power supply system.
Parts and requirements, standard characteristics and general settings, temperature rise limits and test methods.
---Part 2: DC Circuit Breakers. The purpose is to specify the operating conditions and circuit breaking parameters of DC circuit breakers in the ground installations of traction power supply systems.
Instrument characteristics, structure and performance requirements, information and labeling, inspection rules and test methods.
---Part 3: Indoor DC disconnect switches, load switches, and grounding switches. The purpose is to specify the requirements for ground installations in traction power supply systems.
Operating conditions, switching characteristics, structural and performance requirements, information and standards for indoor DC disconnect switches, load switches and grounding switches Identification, inspection rules, and test methods.
---Part 4: Outdoor DC Disconnect Switches, Load Switches, and Grounding Switches. The purpose is to specify the requirements for ground installations in traction power supply systems.
Operating conditions, switching characteristics, structural and performance requirements, information and standards for outdoor DC disconnect switches, load switches and grounding switches.
Identification, inspection rules, and test methods.
---Part 5: DC Switchgear Assemblies. The purpose is to specify the operating procedures for DC switchgear assemblies in ground installations of traction power supply systems.
Operating conditions, characteristics, structure and performance requirements of complete sets of equipment, information and labeling, inspection rules and test methods.
---Part 6-1.General Requirements for Dedicated Measurement, Control, and Protection Devices for DC Traction Power Supply Systems. The purpose is to specify the requirements for DC traction power supply systems.
Characteristics and parameters of measurement, control and protection devices in the power supply system.
---Part 6-2.Dedicated Measurement, Control, and Protection Devices for DC Traction Power Supply Systems. Isolation Current Transmitters and Other Current Measurements Equipment. The purpose is to specify the ground-mounted isolation current transmitters and other equipment used in DC facilities for rail transit systems.
Operating conditions, characteristics, information exchange, inspection rules, and test methods of ground-based current measurement equipment.
---Part 6-3.Dedicated Measurement, Control, and Protection Devices for DC Traction Power Supply Systems. Isolated Voltage Transmitters and Other Voltage Measurement Devices Equipment. The purpose is to specify isolation voltage transmitters and other voltage measurement equipment used in DC facilities for rail transit and ground installations.
Requirements for equipment, as well as isolation voltage transmitters and other DC facilities for rail transit ground installations in traction power supply systems.
Operating conditions, characteristics, information exchange, inspection rules, and test methods of the voltage measurement equipment of the device.
DC switchgear for rail transit ground installations Part 3: Indoor DC Disconnect Switches Load switches and grounding switches
1 Scope
This document specifies the operating conditions, switch...
Characteristics, structural and performance requirements, information and labeling, inspection rules, and related test methods are described.
This document applies to the selection and inspection of indoor DC disconnect switches, load switches, and grounding switches in the ground installation of traction power supply systems.
This document does not apply to the requirements for switchgear assemblies, electromagnetic compatibility (EMC), and reliability, which are defined in GB/T 25890.
His part stipulates.
Note 1.In this document, "switch" refers to "DC disconnect switch and/or load switch" as defined in 3.1.5, 3.1.6 and 3.1.7 of GB/T 25890.1-2026.
and/or grounding switch.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.
For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.
This document.
GB/T 11022-2020 Common technical requirements for high voltage switchgear and controlgear standards (IEC 62271-1:2017, MOD) GB/T 25890.1-2026 DC switchgear for ground installations in rail transit – Part 1: General principles (IEC 61992-1.
2014, MOD)
GB/T 25890.5-2026 DC switchgear for ground installations in rail transit - Part 5: DC switchgear assemblies (IEC 61992-6:2020, MOD) GB/T 32350.1 Railway Transportation - Insulation Coordination - Part 1: Basic Requirements - Clearances and Creepage Distances of Electrical and Electronic Equipment (GB/T 32350.1-2025, IEC 62497-1:2013, MOD)
3 Terms and Definitions
The terms and definitions defined in GB/T 25890.1-2026 apply to this document.
4 Working conditions
The operating conditions of the equipment shall comply with the provisions of section 4.1 of GB/T 25890.1-2026.
5 Switching characteristics
5.1 Feature Overview
The characteristics of a switch include the following items (if applicable).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 11022-2020Common specifications for high-voltage alternating-current switchgear and controlgear standards
- GB/T 25890.1-2026Railway applications - Fixed installations - DC switchgear - Part 1: General
- GB/T 25890.5-2026Railway applications - Fixed installations - DC switchgear - Part 5: DC switchgear assemblies
- GB/T 32350.1Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
- GB/T 32350.1-2025Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
IEC 62271 · IEC 61992 · IEC 62497
How to Download GB/T 25890.3-2026
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 11022-2020 — Common specifications for high-voltage alternating-current switchgear and controlgear standards
GB/T 25890.1-2026 — Railway applications - Fixed installations - DC switchgear - Part 1: General
GB/T 25890.5-2026 — Railway applications - Fixed installations - DC switchgear - Part 5: DC switchgear assemblies
Secure payment via Stripe
Payments accepted
GB/T 25890.3-2026
$350.00