GB/T 25749.9-2012Safety of machinery -- Evaluation of the emission of airborne-hazardous substances -- Part 9: Decontamination index (English PDF)

机械安全 空气传播的有害物质排放的评估 第9部分:净化指数

Preview PDF

This is a limited preview

Buy now to download the full PDF (19 pages)

Need quotation for your management?

Get a formal quotation for GB/T 25749.9-2012 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

May 11, 2012

Implementation date

December 1, 2012

Scope

GB/T 25749.9-2012 is the English-translated version of 机械安全 空气传播的有害物质排放的评估 第9部分:净化指数.

GB/T 25749.9-2012 defines the decontamination index, the figure that says how much cleaner the air around a machine is with its contaminant control system running.

It covers local exhaust capture hoods, spraying systems and separators fitted to the machine, is run with the real contaminant, in a room or on site.

Concentrations are measured at points fixed by a pre-test in three stages: background with the machine off, the machine running with the control system on, then running with the control system off or removed, with at least three readings at each point and the sequence repeated at least twice.

The index serves to rate a system, check an improvement, compare similar designs or set an exhaust air flow. Identical to ISO 29042-9:2011, it was issued on 11 May 2012 and has applied since 1 December 2012.

Found what you need?

Document preview — GB/T 25749.9-2012

National Standard of the People's Republic of China

ICS
13.110
Classification
J 09

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Principle
  • 5 Determine the concentration measurement point
  • 6 Test method
  • 7 Applications for specific machine groups
  • 8 Influencing factors
  • 9 Representation of results
  • 10 Test report
  • Reference

1 Scope

This part of GB/T 25749 specifies pollutant control systems (e.g. capture equipment including local exhaust ventilation, sprinkler systems, and, where appropriate, separation equipment installed on the machine) method of measurement of the purification index. This method uses actual pollutants (see GB/T 25749.1-4.2 in 2010), and can be performed in indoor or field environments.

2 Normative references

The following documents are essential for the application of this document. For dated references, only the dated version applies to this article pieces. For undated references, the latest edition (including all amendments) applies to this document.

ISO 12100 Safety of machinery design general risk assessment and risk reduction (Safety of machinery-General principlesfordesign-Riskassessmentandriskreduction)

3 Terms and Definitions

ISO 12100 and the following terms and definitions apply to this document.

3.1 Decontaminationindex

At several specified locations, the concentrations of pollutants with improved ambient air quality and the The average of the ratios between the mean concentrations of pollutants.

Note 1. Taking into account the air pollution ("background concentration") caused by other operations, make corrections if necessary.

NOTE 2 The improvement in ambient air quality is determined by the difference between the actual pollutant concentrations measured when the pollutant control system is operating or not operating in that environment. Express.

Note 3. When the particle size distribution and pollutant concentration are determined at the same time, the purification index of each particle class can be determined. Examples can be found in ISO 7708.

4 Principles

The principle of this measurement method is to determine the decontamination index specified in 3.1 and the concentration measured at predetermined points around the machine under test, and the Explanation of the index value, taking into account its range of variation and influencing factors.

Measuring the purification index of a pollutant control system can be used to.

a) evaluation of the performance of the machine's pollutant control system;

b) evaluation of pollutant control system improvements;

c) comparisons between machine pollutant control systems of similar design;

d) Classification of pollutant control systems according to purification efficiency;

e) determine the air flow of the exhaust system to the specified level;

f) Determine the technical level of the machine pollutant control system according to the purification efficiency.

5 Determine the concentration measurement point

Measurement points should be determined by pre-testing to ensure that they are located within the measurable discharge area. The number and precise location of the measuring points should be Specified in Type C standards.

6 Test methods

6.1 Overview

If the background concentration level is low, the measurement will be more accurate and its interpretation more reasonable. Whenever possible, concentration measurements should be The surrounding machines and other technological processes are stopped.

Once the measurement point is selected, the measurement procedure will be carried out in three stages (see 6.2~6.4). These three phases are repeated at least twice. two test An example of a measuring point is given in Figure 1.

Measurement procedures used to determine pollutant concentrations should comply with relevant international or national standards. Air flow measurement see

GB/T 2624.1, GB/T 17611, ISO 3966 and ISO 5168.

6.2 Phase 1.Measuring Cfi

When measuring the concentration level Cfi caused by pollutant discharge (background concentration) from surrounding machinery and other processes, the machine under inspection should be turned off If a pollutant control system has been installed, it should also be turned off. Record the operation of surrounding machinery and other processes.

When stable conditions are reached, the concentration is measured at the selected measurement point (see Figure 1). The sampling duration at each measurement point should be the same as the surrounding A representative portion of the duration of pollutant emissions from machinery and other processes corresponds.

At least 3 measurements should be made at each measurement point.

6.3 Phase 2.Measuring Cmi

At this stage, the inspected machine is in operation, and the pollutant control system has been installed, which is also in operation. machine should be specified and the operating conditions of the pollutant control system to which it is connected.

Concentration measurements are carried out according to the specifications in Phase 1.steady state, location of measurement points, sampling time, surrounding machines and other processes operating conditions.

Inspections should be made to confirm that conditions are as close as possible to those in Phase 1.

The sampling duration at each measurement point shall correspond to a representative portion of the pollutant discharge duration of the machine under test.

At least 3 measurements should be made at each measurement point.

6.4 Phase 3.Measuring Cai

The machine under inspection has its contamination control system turned off or removed and remains operational under the same conditions as in Phase 2.If the extraction system can If blockage can occur, the test should not be completed.

WARNING. In some cases, shutting down or changing contaminant control systems can expose operators or persons in the room to dangerously contaminated water flat down. In these cases, appropriate protective measures should be taken to minimize the risk of personal exposure.

Concentrations were measured in a similar manner to the first two stages. However, it should be noted that it may take a long time to stabilize indoors to reach the state.

At least 3 measurements should be made at each measurement point.

7 Applications for specific machine groups

Taking into account a variety of different practical situations (eg. room type, machinery, working method, product variety, operating category, pollutant characteristics), It is not easy to define a completely fixed method that is not bound by the different factors mentioned above.

If the Type C standard gives additional information on specific conditions, the location of the air sampling point, the test, and the duration of sampling should be specified and the operating conditions of the machine.

8 Influencing factors

Many factors can affect the measurement results. Attempts should be made to identify these factors and, if possible, evaluate these factors. very The following points should be recorded.

---Relevant data of the inspected machine, type of working process, type of processed product, type of operation (continuous, batch, cyclic formula), the duration of the operation;

--- Relevant data of surrounding machines and other technological processes;

--- data related to the pollutant control system, especially the exhaust flow of the capture device;

--- Separation of system-related data, especially traffic;

--- the dimensions of the room;

--- data about the layout of the room (e.g. the location of the machine);

--- Relevant data on the overall ventilation system, especially the characteristics of air entry and exhaust equipment, including the rate of cross-interference airflow. same It is also very useful to record air temperature and humidity.

Some methodological difficulties may limit the application of this method in the field, such as.

--- If the spatial and/or temporal differences of pollutants are considered, a large number of measurements are required;

--- Special attention should be paid to minimize fluctuations in exhaust flow and airflow patterns, especially indoors, machines or ventilation devices connected to them Open or close period.

9 Representation of results

The purification index is calculated by formula (1).

The decontamination index was calculated for each measurement point and for each of the three measurements. Then calculate the average of the purification index of each measurement point value. The test result is the average value of the purification index of each measurement point.

Other conditions remain unchanged, the higher the purification index, the higher the efficiency of the pollutant control system.

Example: When IA=0, ie Ca=Cm, the purification system does not contribute to the improvement of air quality. However, when IA=1, that is, Cm=Cf, the purification system can Effectively make indoor air pollution reach the background concentration.

10 Test report

The test report should contain at least the following information.

b) Description of the machine under test and the air purification system for the pollutant control system under test (manufacturer, style, type, modification, design, size, Year of manufacture, serial number, etc.) - the machine itself and each additional piece of equipment;

c) operating data during the test, including the tools used by the machine, the material processed by the machine and the air flow;

d) description of the general ventilation system;

e) a description of the measurement procedure, in particular.

1) method;

2) the location and sampling point of the emission source;

3) the duration of the measurement;

f) the measuring instruments used and the time of the last calibration;

g) environmental data (temperature, humidity, atmospheric pressure);

h) a description of the procedures used for concentration and flow measurements (eg list of standards);

i) test results, including the mean value and 95% confidence interval of different measurement points;

j) a statement of deviation from any relevant standard;

k) laboratory;

l) The name of the person responsible for the test;

m) test data;

n) Other supplementary instructions.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

Referenced standards

Normative references

ISO 12100

How to Download GB/T 25749.9-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 25749.9-2012

$165.00