GB/T 25749.8-2012Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 8: Room method for the measurement of the pollutant concentration parameter (English PDF)
Also coversGBT25749.8-2012
Open the GB/T 25749.8-2012 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
May 11, 2012
Implementation date
December 1, 2012
Scope
GB/T 25749.8-2012 (Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 8: Room method for the measurement of the pollutant concentration parameter) is available as an English-translated PDF.
GB/T 25749.8-2012 — This part of GB/T 25749 specifies that the machine in the air is measured when operating the machine in the test room under given conditions Of the concentration of pollutants in the given concentration of harmful substances. This method is only applicable to the local exhaust ventilation air flow >= 500m3/h The machine and the machine without air circulation. Measure the pollutant concentration parameters of the machine and can be used to. a) assess the performance of the machine; b) assessment of machine improvements; c) comparison between groups of machines of the same intended use (this group is defined by function and processing material); d) classify the same set of machines according to the pollutant concentration parameters; e) Determine the technical level of the machine according to the pollutant concentration parameter.
Document preview — GB/T 25749.8-2012
National Standard of the People's Republic of China
- ICS
- 13.110
- Classification
- J 09
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 normative reference documents
- 3 terms and definitions
- 4 principle
Foreword
GB/T 25749 "Assessment of Hazardous Substances in Airborne Airborne Discharge" consists of the following nine parts.
- Part 1. Selection of test methods;
- Part 2. Tracer gas method for measuring emissions of a given pollutant;
- Part 3. Test bench method for measuring the emission rate of a given pollutant;
- Part 4. Tracer method for measuring the efficiency of exhaust system capture;
- Part 5. Test bench method for measuring the quality separation efficiency of air purification systems without conduit exports;
- Part 6. Test bench method for measuring the quality separation efficiency of air purification systems with conduit outlet;
- Part 7. Test bench method for measuring pollutant concentration parameters;
- Part 8. Indoor method for measuring pollutant concentration parameters;
Part 9. Purification Index.
This part is part 8 of GB/T 25749.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part is equivalent to the use of international standards ISO 29042-8..2011 "Mechanical safety assessment of harmful substances in the air emissions Part 8.
Indoor Method for Measuring Contaminant Concentration "(in English).
This part is equivalent to translation ISO 29042-8..2011. For ease of use, this section has made the following editorial changes.
- the terms of the ISO /TC199 work and the relationship with ISO 19042-8 and EN1903-9 were deleted from the introduction
content.
This part of the National Machinery Safety Standardization Technical Committee (SAC/TC208) proposed and centralized.
This part of the drafting unit. Shenzhen City, China Testing Co., Ltd., Nanjing Forestry University Institute of optical and electrical engineering, mechanical science research
General Hospital.
Introduction
The mechanical safety standards are structured as follows.
- Class A standard (basic safety standard), given the basic concepts, design principles and general characteristics applicable to all machinery;
- Class B standards (general safety standards), involving a safety feature in the machinery or a wide range of use of a class of safety devices.
* Class B1, specific safety features (eg safety distance, surface temperature, noise) standard;
* Class B2, safety devices (eg hands operated devices, interlocks, pressure sensitive devices, protective devices)
- Class C standards (machine safety standards) that specify a detailed safety requirement for a particular machine or group of machines.
According to GB/T 15706, this part belongs to class B standard.
Class C standards may supplement or modify the terms of this section.
For machines designed and constructed in accordance with Class C standards, if the provisions of Class C standards are inconsistent with Class A or Class B criteria,
Using Class C standards.
Mechanical safety airborne emissions of harmful substances
Evaluation Part 8. Measuring Contaminant Concentration
Parameter of the interior method
1 Scope
This part of GB/T 25749 specifies that the machine in the air is measured when operating the machine in the test room under given conditions
Of the concentration of pollutants in the given concentration of harmful substances. This method is only applicable to the local exhaust ventilation air flow >= 500m3/h
The machine and the machine without air circulation.
Measure the pollutant concentration parameters of the machine and can be used to.
a) assess the performance of the machine;
b) assessment of machine improvements;
c) comparison between groups of machines of the same intended use (this group is defined by function and processing material);
d) classify the same set of machines according to the pollutant concentration parameters;
e) Determine the technical level of the machine according to the pollutant concentration parameter.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
ISO 2602 Statistical analysis of the results of the data Estimated confidence interval (Statisticalinterpretationoftestresults-
Estimationofthemean-Confidenceinterval)
ISO 12100 Mechanical Safety Design General Risk Assessment and Risk Reduction (Safetyofmachinery-General
principlesfordesign-Riskassessmentandriskreduction
3 terms and definitions
ISO 12100 and the following terms and definitions apply to this document.
3.1
Indoor Pollutant Concentration Parameters polutantconcentrationparameteroftheroom
Pcr
The concentration of a given pollutant measured at a specified location near the machine.
Note. In this section, the measurement point is the position specified around the machine and the pollutant concentration parameter is the average of the measured concentration.
4 principle
The principle of this measurement method is to operate in a test room under controlled conditions with strong local exhaust ventilation (>=500m3/h) and
Measure the contaminant concentration at the specified location (see 5.2). The average concentration represents an indicator of machine emissions, and the standard deviation represents the emissions
Dispersion of an indicator.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
How to Buy GB/T 25749.8-2012
- 1Add to cart. Click the "Buy GB/T 25749.8-2012" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 25749.2-2010 — Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 2: Tracer gas method for the measurement of the emission rate of a given pollutant
GB/T 25749.3-2010 — Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 3: Test bench method for the measurement of the emission rate of a given pollutant
GB/T 25749.4-2010 — Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 4: Tracer method for the measurement of the capture efficiency of an exhaust system
Secure payment via Stripe
Payments accepted
GB/T 25749.8-2012
$110.00