GB/T 25313-2010The standardization for the evaluation of electromagnetic field distribution of welding equipment (English PDF)
焊接设备电磁场检测与评估准则
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 25313-2010 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 10, 2010
Implementation date
May 1, 2011
Scope
GB/T 25313-2010 is the English-translated version of 焊接设备电磁场检测与评估准则.
GB/T 25313-2010 fixes the test conditions and the evaluation methods for the electromagnetic field radiated by arc welding and resistance welding equipment working normally.
Clause 1 limits the standard to radiation at frequencies below 1 MHz and, following what current instruments can actually measure, to a measured range running from 10 Hz or lower up to 400 kHz or higher; it states that the standard applies to resistance welding and arc welding equipment.
Its contents list names a scope clause, normative references, terms and definitions, clause 4 on the detection method, clause 5 on the measuring apparatus and the measurement conditions, clause 6 on the test report and clause 7 on exemption management, followed by informative Annex A explaining low frequency electromagnetic fields.
Clause 3 defines the maximum r.m.s. value of the electric field and of the magnetic field as the r.m.s. value along the semi-major axis of the field ellipse at a given measuring point, lists the quasi-static field among the terms and also defines the resultant electric and magnetic fields, which are expressed either from the three orthogonal components or from the semi-major and semi-minor axes of the field ellipse.
The foreword records that the document draws on the ICNIRP guidelines of 1998 for limiting exposure to electric, magnetic and electromagnetic fields up to 300 GHz recommended by the World Health Organization, on IEEE/ICES IEEE C95.6-2002 on safety levels for human exposure to electromagnetic fields from 0 to 3 kHz, and on the November 2008 draft of the Chinese Ministry of Environmental Protection on electromagnetic radiation exposure limits and measurement methods, adapted to Chinese conditions and set for the case of equipment operating without an operator present.
Clause 2 cites GB/T 6113.101 on radio disturbance and immunity measuring apparatus and methods. The standard was proposed by the China Electrical Equipment Industrial Association and is administered by the national welding standardization technical committee, SAC/TC70. It was issued on 10 November 2010 and has applied since 1 May 2011.
Found what you need?
Document preview — GB/T 25313-2010
National Standard of the People's Republic of China
- ICS
- 25.160.30
- Classification
- J 64
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 detection method
- 5 measurement apparatus and Condition
- 6 Test Report
- 7 Exemption Management
- Appendix A (informative) Explanation 6 low frequency electromagnetic fields
Foreword
The standards, the reference to the World Health Organization recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) "time limit electric field, Magnetic and electromagnetic fields (300GHz or less) exposure guidelines, 1998, "Institute of Electrical and Electronics Engineers/International Committee on Electromagnetic Safety (IEEE/ICES) "(IEEEC95.6-2002) on human exposure to electromagnetic fields 0 ~ 3kHz level of safety" and China's Ministry of Environmental Protection "Electromagnetic Radiation exposure limits and measurement methods "(November 2008 draft), combined with China's national conditions, made in the absence of the operator, the normal work Under test conditions and evaluation methods for the case of welding equipment produced by electromagnetic radiation. Appendix A of this standard is an informative annex. The standard proposed by China Electrical Equipment Industrial Association.
1 Scope
This standard specifies the radiated electromagnetic field and arc welding equipment under normal operating conditions generated strong test conditions and evaluation method. Frequency of electromagnetic radiation involved is less than 1MHz. According to the current actual ability to detect electromagnetic radiation, the frequency is detected from 10Hz (or less) to 400kHz (or higher) range.
This standard applies to electrical resistance welding and arc welding equipment.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 6113.101 radio disturbance and immunity measuring apparatus and methods - Part 1-1. Radio disturbance and anti- Interference measuring equipment measuring equipment
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1 Rms electric field maximum
A given measurement point semi-major axis of the ellipse field rms values.
3.2 Rms maximum magnetic field
A given measurement point semi-major axis of the ellipse field rms values.
3.3 Quasi-static field
3.4 Resultant electric field
Field synthesis is expressed as. ER = E2x E2y E2z among them.
Ex, Ey, Ez are the rms value of the three orthogonal components of the electric field. Or expressed as. ER = E2max E2min among them.
Emax, Emin field were oval semi-major axis and semi-minor axis RMS.
3.5 Resultant magnetic field
Synthetic magnetic field is expressed as.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 25313-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6113.101-2008 — Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
GB/T 6113.101-2016 — Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
GB/T 6113.101-2021 — Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus
Secure payment via Stripe
Payments accepted
GB/T 25313-2010