Scope

GB/T 25094-2010 is the English-translated version of 架空输电线路抢修杆塔通用技术条件.

GB/T 25094-2010 is the Chinese standard "General technical specification of corrective maintenance tower for overhead transmission line".

Its scope clause reads: This standard specifies the overhead transmission line tower repair classification, technical requirements, test methods, inspection rules and signs, packaging, transportation, storage Memory and so on.

This standard is applicable to the exchange 110 (66) kV ~ 500kV overhead transmission lines, other voltage overhead transmission lines can refer use. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 25094-2010

National Standard of the People's Republic of China

ICS
29.240.20
Classification
K 47

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Category
  • 5 2 Technical Requirements
  • 6 Test methods
  • 7 inspection rules
  • 8 packaging, marking, transportation and storage
  • Appendix A (informative) Typical repair tower line diagram
  • Appendix B (normative) tower materials Main specifications
  • Annex C (normative) Repair towers overall mechanical testing arrangement
  • Annex D (informative) repair tower group sets up guidelines

1 Scope

This standard specifies the overhead transmission line tower repair classification, technical requirements, test methods, inspection rules and signs, packaging, transportation, storage

Memory and so on.

This standard is applicable to the exchange 110 (66) kV ~ 500kV overhead transmission lines, other voltage overhead transmission lines can refer use.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent

Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research

Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 191 Packaging - Pictorial signs (GB/T 191-2008, ISO 780.1997, MOD)

GB/T 700 carbon structural steel (GB/T 700-2006, ISO 630.1995, NEQ)

GB/T 1591 high strength low alloy structural steel

GB/T 2900.51 Electrotechnical terminology overhead lines (GB/T 2900.51-1998, idt IEC 60050 (466).1990)

GB/T 3098.1 Mechanical properties of fasteners Bolts, screws and studs (GB/T 3098.1-2000, idt ISO 898-1.1999)

GB/T 3098.2 Mechanical properties of fasteners - Nuts - Coarse thread (GB/T 3098.2-2000, idt ISO 898-2.1992)

GB/T 3195 aluminum and aluminum wire drawing round

GB/T 5117 carbon steel electrode

GB/T 6892 General Industrial aluminum and aluminum alloy extrusion profiles

GB/T 12467 (all parts) Quality requirements for welding - Fusion welding of metallic materials (ISO 3834-1 ~ 3834-4.1994, IDT)

GB 13398 live working hollow insulating tube, filled with an insulating foam insulation tubes and solid rods (GB 13398-2008, IEC 60855.

1985; IEC 61235.1993, MOD)

GB/T 16927.1 High-voltage test techniques Part 1. General test requirements (GB/T 16927.1-1997, eqv

IEC 60060-1. 1989)

GB/T 19519 nominal voltage above 1000V ac overhead lines with composite insulators --- Definitions, test methods and acceptance quasi

Then (GB/T 19519-2004, IEC 61109.1992, MOD)

DL409 electrical safety regulations (power line section)

DL/T 5092-1999 (110 ~ 500) kV overhead transmission line design technical regulations

3 Terms and Definitions

By the GB/T 2900.51 determined and the following terms and definitions apply to this standard.

3.1 Repair towers correctivemaintenancetower

For Transmission Line Tower Collapses After temporary recovery tower special power. Operational time is generally not more than three months.

3.2 Tower segment sectoftower

According to a certain length of the combined member will tower segment.

GB/T 37404-2019 | GB/T 2694-2018 | GB/T 31487.3-2015 | GB/T 13398-2026 | GB/T 18037-2025 | GB/T 31235-2024 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 25094-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation.

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 25094-2010

$135.00